Three-dimensional finite element analysis of the uprighting movement of mandibular mesially inclined second molars

被引:0
|
作者
Zheng, Bowen [1 ]
Ran, Junyi [1 ]
He, Jia [1 ]
Al-Yafrusee, Enas Senan Ali Mohammed [1 ]
Zhao, Yang [1 ]
Liu, Yi [1 ]
机构
[1] China Med Univ, Liaoning Prov Key Lab Oral Dis, Sch & Hosp Stomatol, Dept Orthodont, Nanjing North St 117, Shenyang 110002, Liaoning, Peoples R China
关键词
TOOTH-MOVEMENT; ANCHORAGE; IMPACTION; ERUPTION;
D O I
10.1016/j.ajodo.2023.09.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The mesially inclined mandibular second molar can be supported upright by the microimplant anchorage. This study established the finite element model to analyze the displacement trend and periodontal ligament (PDL) stress distribution of the uprighting mandibular second molar with the microimplant under different conditions. Methods: A 3 -dimensional model of the mandible and dentition was established. The mesial inclination of the mandibular second molar was 30 degrees, 45 degrees, and 60 degrees. Microimplants were implanted between the buccal side of the second premolar and the first molar and in the distal part of the mandibular second molar, respectively. Six groups were set, each loaded with 0.5 N of force. The second molar initial displacement trend and PDL stress distribution were evaluated. Results: The PDL stress of mandibular second molars in all groups was within the physiological limit, and the PDL stress of mandibular second molars in the distal implant groups was lower than that of mandibular second molars in the mesial implant groups. PDL stress concentration in the cervical area. Tooth displacement decreased as the mesial inclination angle of the second molars increased. The sagittal displacement of mesial implant groups was larger, and there was a tendency of mesiobuccal torsion when standing uprighting; the vertical displacement of distal implant groups was larger, and there was a tendency of distal lingual torsion when standing uprighting. Conclusions: Distal microimplant has a better extrusion effect on the mesially inclined second molar, whereas mesial microimplant has a better effect on the distal movement. The optimal orthodontic force for microimplant traction on mesially inclined second molars is 0.5-0.8 N. (Am J Orthod Dentofacial Orthop 2024;165:314-20)
引用
收藏
页码:314 / 320
页数:7
相关论文
共 50 条
  • [1] Uprighting mesially impacted mandibular permanent second molars
    Shapira, Y
    Borell, G
    Nahlieli, O
    Kuftinec, MM
    Stom, D
    [J]. ANGLE ORTHODONTIST, 1998, 68 (02) : 173 - 178
  • [2] Torqued and conventional cantilever for uprighting mesially impacted molars: A 3-dimensional finite element analysis
    Barros, Sergio Estelita
    Faria, Juliana
    Cevallos, Katherine Jaramillo
    Chiqueto, Kelly
    Machado, Leonardo
    Noritomi, Pedro
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 162 (04) : E203 - E215
  • [3] The management of mesially inclined/impacted mandibular permanent second molars
    Turley, Patrick K.
    [J]. JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2020, 9 (03) : S45 - S53
  • [4] Three-Dimensional Analysis of Pulp Chambers in Mandibular Second Deciduous Molars
    Ikari, Yasutoyo
    Kinoshita, Hideaki
    Agematsu, Hiroko
    Saka, Hideki
    Matsunaga, Satoru
    Ide, Yoshinobu
    Abe, Shinichi
    [J]. JOURNAL OF HARD TISSUE BIOLOGY, 2014, 23 (02) : 211 - 215
  • [5] Three-dimensional measurement and analysis of mandibular characteristics in subjects with impacted mandibular second molars
    Fan, Wei
    Gao, Deguo
    Wang, Yuting
    Chen, Yutong
    Li, Yusheng
    Lu, Shijun
    Wang, Zhendong
    [J]. ORTHODONTICS & CRANIOFACIAL RESEARCH, 2020, 23 (03) : 332 - 341
  • [6] Effect of biomimetic material on stress distribution in mandibular molars restored with inlays: a three-dimensional finite element analysis
    Zhu, Junxin
    Luo, Danmei
    Rong, Qiguo
    Wang, Xiaoyan
    [J]. PEERJ, 2019, 7
  • [7] Three-dimensional finite element analysis of the seismic behavior of inclined micropiles
    Sadek, M
    Isam, S
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2004, 24 (06) : 473 - 485
  • [8] A Preliminary Three-Dimensional Finite Element Analysis of Mandibular Implant Overdentures
    Petrie, Cynthia S.
    Walker, Mary P.
    Lu, Yunkai
    Thiagarajan, Ganesh
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (01) : 70 - 72
  • [9] Three-dimensional finite element analysis of the composite and compomer onlays in primary molars
    Kirzioglu, Zuhal
    Ceyhan, Derya
    Sengul, Fatih
    Altun, Ayse Ceren
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (10) : 936 - 941
  • [10] Evaluation of Mandibular Angle Ostectomy Using Three-Dimensional Finite Element Analysis
    Song, Jian
    Zhu, Songsong
    Luo, En
    Hu, Jing
    Feng, Ge
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (04) : E375 - E378