Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

被引:20
|
作者
Delso, Gaspar
Fuerst, Sebastian
Jakoby, Bjoern [1 ,2 ]
Ladebeck, Ralf [3 ]
Ganter, Carl [4 ]
Nekolla, Stephan G.
Schwaiger, Markus
Ziegler, Sibylle I.
机构
[1] Univ Surrey, Guildford GU2 5XH, Surrey, England
[2] Siemens Med Solut USA Inc, Knoxville, TN USA
[3] Siemens Healthcare, Erlangen, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Radiol, D-8000 Munich, Germany
关键词
PET/MR; NEMA; performance;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The recently released Biograph mMR is the first commercially available integrated whole-body PET/MR scanner. There are considerable advantages to integrating both modalities in a single scanner that enables truly simultaneous acquisition. However, there are also concerns about the possible degradation of both PET and MR performance in an integrated system. This paper evaluates the performance of the Biograph mMR during independent and simultaneous acquisition of PET and morphologic MR data. Methods: The NEMA NU 2-2007 protocol was followed for studying the PET performance. The following measurements were performed: spatial resolution; scatter fraction, count losses, and randoms; sensitivity; accuracy of the correction for count losses and randoms; and image quality. The quality control manual of the American College of Radiology was followed for studying the MR performance. The following measurements were performed: geometric accuracy, spatial resolution, low-contrast detectability, signal-to-noise ratio, static field (B-0) homogeneity, radiofrequency field (B-1) homogeneity, and radiofrequency noise. Results: An average spatial resolution of 4.3 mm in full width at half maximum was measured at 1 cm offset from the center of the field of view. The system sensitivity was 15.0 kcps/MBq along the center of the scanner. The scatter fraction was 37.9%, and the peak noise-equivalent count rate was 184 kcps at 23.1 kBq/mL. The maximum absolute value of the relative count rate error due to dead-time losses and randoms was 5.5%. The average residual error in scatter and attenuation correction was 12.1%. All MR parameters were within the tolerances defined by the American College of Radiology. B0 inhomogeneities below 1 ppm were measured in a 120-mm radius. B1 homogeneity and signal-to-noise ratio were equivalent to those of a standard MR scanner. No radiofrequency interference was detected. Conclusion: These results compare favorably with other state-of-the-art PET/CT and PET/MR scanners, indicating that the integration of the PET detectors in the MR scanner and their operation within the magnetic field do not have a perceptible impact on the overall performance. The MR subsystem performs essentially like a standalone system. However, further work is necessary to evaluate the more advanced MR applications, such as functional imaging and spectroscopy.
引用
收藏
页码:1914 / 1922
页数:9
相关论文
共 50 条
  • [21] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [22] Sparse crystal setting and large axial FOV for integrated whole-body PET/MR
    Salomon, Andre
    Truhn, Daniel
    Botnar, Rene
    Kiessling, Fabian
    Schulz, Volkmar
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2521 - 2523
  • [23] Whole-body MR/PET: applications in abdominal imaging
    Schwenzer, N. F.
    Schmidt, H.
    Claussen, C. D.
    ABDOMINAL IMAGING, 2012, 37 (01): : 20 - 28
  • [24] Whole-body MR/PET: applications in abdominal imaging
    N. F. Schwenzer
    H. Schmidt
    C. D. Claussen
    Abdominal Imaging, 2012, 37 : 20 - 28
  • [25] Design and performance simulation studies of a breast PET insert integrable into a clinical whole-body PET/MRI scanner
    Pommranz, C. M.
    Schmidt, F. P.
    Mannheim, J. G.
    Diebold, S. J.
    Tenzer, C.
    Santangelo, A.
    Pichler, B. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [26] Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone Lesions
    Eiber, Matthias
    Takei, Toshiki
    Souvatzoglou, Michael
    Mayerhoefer, Marius E.
    Fuerst, Sebastian
    Gaertner, Florian C.
    Loeffelbein, Denys J.
    Rummeny, Ernst J.
    Ziegler, Sibylle I.
    Schwaiger, Markus
    Beer, Ambros J.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 191 - 197
  • [27] Performance of a whole-body PET scanner using curve-plate NaI(Tl) detectors
    Adam, LE
    Karp, JS
    Daube-Witherspoon, ME
    Smith, RJ
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (12) : 1821 - 1830
  • [28] Combined Analog/Digital Approach to Performance Optimization for the LAPET Whole-Body TOF PET Scanner
    Ashmanskas, W. J.
    Davidson, Z. S.
    LeGeyt, B. C.
    Newcomer, F. M.
    Panetta, J. V.
    Ryan, W. A.
    Van Berg, R.
    Wiener, R. I.
    Karp, J. S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3496 - 3500
  • [29] Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors
    Akamatsu, Go
    Tashima, Hideaki
    Iwao, Yuma
    Wakizaka, Hidekatsu
    Maeda, Takamasa
    Mohammadi, Akram
    Takyu, Sodai
    Nitta, Munetaka
    Nishikido, Fumihiko
    Rutherford, Harley
    Chacon, Andrew
    Safavi-Naeini, Mitra
    Yoshida, Eiji
    Yamaya, Taiga
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09):
  • [30] Design and performance of a prototype whole-body PET/CT scanner with fiber-optic readout
    Worstell, W
    Adler, S
    Domigan, P
    Johnson, O
    Kudrolli, H
    Lazuka, D
    Monteverde, P
    Nevin, J
    Rohatgi, R
    Romanov, L
    Starsja, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3280 - 3284