Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

被引:20
|
作者
Delso, Gaspar
Fuerst, Sebastian
Jakoby, Bjoern [1 ,2 ]
Ladebeck, Ralf [3 ]
Ganter, Carl [4 ]
Nekolla, Stephan G.
Schwaiger, Markus
Ziegler, Sibylle I.
机构
[1] Univ Surrey, Guildford GU2 5XH, Surrey, England
[2] Siemens Med Solut USA Inc, Knoxville, TN USA
[3] Siemens Healthcare, Erlangen, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Radiol, D-8000 Munich, Germany
关键词
PET/MR; NEMA; performance;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The recently released Biograph mMR is the first commercially available integrated whole-body PET/MR scanner. There are considerable advantages to integrating both modalities in a single scanner that enables truly simultaneous acquisition. However, there are also concerns about the possible degradation of both PET and MR performance in an integrated system. This paper evaluates the performance of the Biograph mMR during independent and simultaneous acquisition of PET and morphologic MR data. Methods: The NEMA NU 2-2007 protocol was followed for studying the PET performance. The following measurements were performed: spatial resolution; scatter fraction, count losses, and randoms; sensitivity; accuracy of the correction for count losses and randoms; and image quality. The quality control manual of the American College of Radiology was followed for studying the MR performance. The following measurements were performed: geometric accuracy, spatial resolution, low-contrast detectability, signal-to-noise ratio, static field (B-0) homogeneity, radiofrequency field (B-1) homogeneity, and radiofrequency noise. Results: An average spatial resolution of 4.3 mm in full width at half maximum was measured at 1 cm offset from the center of the field of view. The system sensitivity was 15.0 kcps/MBq along the center of the scanner. The scatter fraction was 37.9%, and the peak noise-equivalent count rate was 184 kcps at 23.1 kBq/mL. The maximum absolute value of the relative count rate error due to dead-time losses and randoms was 5.5%. The average residual error in scatter and attenuation correction was 12.1%. All MR parameters were within the tolerances defined by the American College of Radiology. B0 inhomogeneities below 1 ppm were measured in a 120-mm radius. B1 homogeneity and signal-to-noise ratio were equivalent to those of a standard MR scanner. No radiofrequency interference was detected. Conclusion: These results compare favorably with other state-of-the-art PET/CT and PET/MR scanners, indicating that the integration of the PET detectors in the MR scanner and their operation within the magnetic field do not have a perceptible impact on the overall performance. The MR subsystem performs essentially like a standalone system. However, further work is necessary to evaluate the more advanced MR applications, such as functional imaging and spectroscopy.
引用
收藏
页码:1914 / 1922
页数:9
相关论文
共 50 条
  • [31] 3D reconstruction with an extended system model for the new Biograph mMR whole-body MR/PET system
    Kraus, Rebekka
    Delso, Gaspar
    Cheng, Xiaoyin
    Ziegler, Sibylle
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [32] Comparison of lesion detection between a simultaneously acquiring whole-body PET-MR hybrid scanner and PET-CT
    Gall, Carl V.
    Quick, Harald
    Wiesmueller, Marco
    Uder, Michael
    Schmidt, Daniela
    Kuwert, Torsten
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [33] CLINICAL WHOLE-BODY COUNTING - WHOLE-BODY SCANNER WITH 2 CRYSTALS
    REIZENSTEIN, P
    KARLSSON, HA
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1966, 4 (03): : 209 - +
  • [34] First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
    Drzezga, Alexander
    Souvatzoglou, Michael
    Eiber, Matthias
    Beer, Ambros J.
    Fuerst, Sebastian
    Martinez-Moeller, Axel
    Nekolla, Stephan G.
    Ziegler, Sibylle
    Ganter, Carl
    Rummeny, Ernst J.
    Schwaiger, Markus
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) : 845 - 855
  • [35] Three-way Comparison of Whole-Body MR, Coregistered Whole-Body FDG PET/MR, and Integrated Whole-Body FDG PET/CT Imaging: TNM and Stage Assessment Capability for Non-Small Cell Lung Cancer Patients
    Ohno, Yoshiharu
    Koyama, Hisanobu
    Yoshikawa, Takeshi
    Takenaka, Daisuke
    Seki, Shinichiro
    Yui, Masao
    Yamagata, Hitoshi
    Aoyagi, Kota
    Matsumoto, Sumiaki
    Sugimura, Kazuro
    RADIOLOGY, 2015, 275 (03) : 849 - 861
  • [36] Integrated Whole Body MR/PET: Where Are We?
    Yoo, Hye Jin
    Lee, Jae Sung
    Lee, Jeong Min
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 32 - 49
  • [37] Initial results of simultaneous whole-body ToF PET/MR
    Levin, Craig
    Deller, Timothy
    Peterson, William
    Maramraju, Sri Harsha
    Kim, Changlyong
    Prost, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [38] Effect of MR truncation compensation on quantitative PET image reconstruction for whole-body PET/MR
    Tang, Jing
    Haagen, Rainald
    Blaffert, Thomas
    Renisch, Steffen
    Blaeser, Andreas
    Salomon, Andre
    Schweizer, Bernd
    Hu, Zhiqiang
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2506 - 2509
  • [39] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [40] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52