The Freiburg Stereoacuity Test: automatic measurement of stereo threshold

被引:30
|
作者
Bach, M [1 ]
Schmitt, C [1 ]
Kromeier, M [1 ]
Kommerell, G [1 ]
机构
[1] Univ Freiburg, Augenklin, Abt Neuroophthalmol & Schielbehandlung, D-79106 Freiburg, Germany
关键词
D O I
10.1007/s004170100317
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: There is a need for a stereotest with the following properties: (1) Natural viewing conditions, i.e. stimulus contours visible for each eye alone, but no or hardly any cue for monocular detection, and (2) suitability for threshold determination over a wide range of disparities. To comply with these requirements, we developed the Freiburg Stereoacuity Test. Method: The stimulus configuration is shown on a visual display unit (VDU) using phase-difference haploscopy with ferromagnetic liquid crystal shutters. The stereo target consists of a vertical bar that can be presented "in front of" or "behind" a frame. The sizes of the bar and the frame are kept constant relative to the stereo disparity. Anti-aliasing allows for disparities finer than the pixel raster. To mask monocular cues the bar is displaced randomly to the right or left. The stereo threshold was determined in two observers with normal eyes, using first the method of constant stimuli and then the best PEST. Both procedures were repeated with observers wearing scatter transparencies that reduced their visual acuity to about 1/10. In addition, the two observers with insight into the test design and two strabismic patients performed the best PEST procedure with one eye only. Results: With constant stimuli both observers achieved a stereoacuity of 2.6 arcsec and 3.1 arcsec, respectively, taking a hit rate of 75% as the threshold. The best PEST revealed a stereoacuity of 2.5 arcsec and 3.0 arcsec, respectively. The scatter transparencies raised the threshold to 261 and 257, respectively. With one eye only, the two observers with insight into the test design exploited the subtle position cue and reached a coarse pseudostereopsis. The two strabismic patients did not utilise the position cue. Conclusion: The Freiburg Stereoacuity Test allows determination of stereoacuity over a wide range of disparities (1-1000 arcsec). Although the stimuli can be seen with each eye alone, monocular depth cues are sufficiently masked. The Freiburg Stereoacuity Test is available at http://www.ukl.uni-frei-burg.de/aug/bach/fst/.
引用
收藏
页码:562 / 566
页数:5
相关论文
共 50 条
  • [21] Automatic measurement of tool dimension using stereo CCD-cameras
    Andresen, K
    Neugebauer, M
    OPTICAL INSPECTION AND MICROMEASUREMENTS, 1996, 2782 : 612 - 619
  • [22] STEREO SEARCH - LATERAL APPROACH TO AUTOMATIC BUBBLE-CHAMBER MEASUREMENT
    RAJA, R
    NUCLEAR INSTRUMENTS & METHODS, 1975, 126 (02): : 247 - 251
  • [23] DISTORTED FREIBURG SPEECH TEST
    DIEROFF, HG
    MEISSNER, W
    LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1985, 64 (09): : 466 - 469
  • [24] Development of Manual Measurement System with Stereo Markers for Lachman Test
    Long, Zhongjie
    Kawaguchi, Shogo
    Nagamune, Kouki
    JOURNAL OF ADVANCED COMPUTATIONAL INTELLIGENCE AND INTELLIGENT INFORMATICS, 2016, 20 (03) : 385 - 392
  • [25] Assessment of a new distance randot stereoacuity test
    Fu, Valeria L. N.
    Birch, Eileen E.
    Holmes, Jonathan M.
    JOURNAL OF AAPOS, 2006, 10 (05): : 419 - 423
  • [26] Effects of Target Size and Test Distance on Stereoacuity
    Iwata, Yo
    Fujimura, Fusako
    Handa, Tomoya
    Shoji, Nobuyuki
    Ishikawa, Hitoshi
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [27] Comparing stereotests: the TNO test overestimates stereoacuity
    Vancleef, Kathleen
    Read, Jenny
    Herbert, William
    Goodship, Nicola
    Woodhouse, Maeve
    Serrano-Pedraza, Ignacio
    PERCEPTION, 2016, 45 : 114 - 114
  • [28] A Clinical usefulness black randot stereoacuity test
    Yang, J
    Choi, M
    Son, M
    Yun, I
    Won, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U963 - U963
  • [29] Automatic ventricular threshold measurement in children with epicardial pacing leads
    Hiippala, A
    Clausson, E
    Ekblad, H
    Leskinen, M
    Happonen, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (01): : 41 - 47
  • [30] Automatic volume measurement of lung nodules: optimal threshold density
    Paslawski, Marek
    Krzyzanowski, Konrad
    Kurys, Ewa
    POLISH JOURNAL OF RADIOLOGY, 2006, 71 (02) : 13 - 17