The Freiburg Stereoacuity Test: automatic measurement of stereo threshold

被引:30
|
作者
Bach, M [1 ]
Schmitt, C [1 ]
Kromeier, M [1 ]
Kommerell, G [1 ]
机构
[1] Univ Freiburg, Augenklin, Abt Neuroophthalmol & Schielbehandlung, D-79106 Freiburg, Germany
关键词
D O I
10.1007/s004170100317
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: There is a need for a stereotest with the following properties: (1) Natural viewing conditions, i.e. stimulus contours visible for each eye alone, but no or hardly any cue for monocular detection, and (2) suitability for threshold determination over a wide range of disparities. To comply with these requirements, we developed the Freiburg Stereoacuity Test. Method: The stimulus configuration is shown on a visual display unit (VDU) using phase-difference haploscopy with ferromagnetic liquid crystal shutters. The stereo target consists of a vertical bar that can be presented "in front of" or "behind" a frame. The sizes of the bar and the frame are kept constant relative to the stereo disparity. Anti-aliasing allows for disparities finer than the pixel raster. To mask monocular cues the bar is displaced randomly to the right or left. The stereo threshold was determined in two observers with normal eyes, using first the method of constant stimuli and then the best PEST. Both procedures were repeated with observers wearing scatter transparencies that reduced their visual acuity to about 1/10. In addition, the two observers with insight into the test design and two strabismic patients performed the best PEST procedure with one eye only. Results: With constant stimuli both observers achieved a stereoacuity of 2.6 arcsec and 3.1 arcsec, respectively, taking a hit rate of 75% as the threshold. The best PEST revealed a stereoacuity of 2.5 arcsec and 3.0 arcsec, respectively. The scatter transparencies raised the threshold to 261 and 257, respectively. With one eye only, the two observers with insight into the test design exploited the subtle position cue and reached a coarse pseudostereopsis. The two strabismic patients did not utilise the position cue. Conclusion: The Freiburg Stereoacuity Test allows determination of stereoacuity over a wide range of disparities (1-1000 arcsec). Although the stimuli can be seen with each eye alone, monocular depth cues are sufficiently masked. The Freiburg Stereoacuity Test is available at http://www.ukl.uni-frei-burg.de/aug/bach/fst/.
引用
收藏
页码:562 / 566
页数:5
相关论文
共 50 条
  • [41] Interobserver test-retest reliability of the randot preschool stereoacuity test
    Fawcett, SL
    Birch, EE
    JOURNAL OF AAPOS, 2000, 4 (06): : 354 - 358
  • [42] Stereo vision measurement system qualification and preliminary performance test results
    Finotello, R.
    Losito, S.
    Mondellini, C.
    Rossi, G.
    Zampato, M.
    European Space Agency, (Special Publication) ESA SP, 2005, (603): : 617 - 623
  • [43] Contribution to the Discussion on the Freiburg Speech Test
    Kollmeier, B.
    Lenarz, T.
    Kiessling, J.
    Mueller-Deile, J.
    Steffens, T.
    v. Wedel, H.
    Doering, W. H.
    Buschermoehle, M.
    Wagener, K.
    Brand, T.
    HNO, 2014, 62 (01) : 49 - 53
  • [44] Calibration of the Freiburg Monosyllabic Speech Test
    Holube, I.
    Steffens, T.
    Winkler, A.
    HNO, 2019, 67 (04) : 304 - 305
  • [45] The Freiburg monosyllabic speech test in noise
    Winkler, A.
    Holube, I.
    Husstedt, H.
    HNO, 2020, 68 (01) : 14 - 24
  • [46] An automatic test pattern generation framework for combinational threshold logic networks
    Gupta, P
    Zhang, R
    Jha, NK
    IEEE INTERNATIONAL CONFERENCE ON COMPUTER DESIGN: VLSI IN COMPUTERS & PROCESSORS, PROCEEDINGS, 2004, : 540 - 543
  • [47] Automatic Test Bench for Measurement of Magnetic Interference on LVDTs
    Spiezia, Giovanni
    Losito, Roberto
    Martino, Michele
    Masi, Alessandro
    Pierno, Antonio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (05) : 1802 - 1810
  • [48] Dynamic measurement method of integrated automatic test equipment
    Mao, Hong-Yu
    Yang, Guang
    Wang, Wen-Liang
    Hu, Zhuo-Lin
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2010, 40 (01): : 119 - 122
  • [49] Automatic Test Bench for the Measurement of the Magnetic Interference on LVDTs
    Spiezia, G.
    Losito, R.
    Martino, M.
    Masi, A.
    Pierno, A.
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [50] Measurement of distortion waveform in magnetic parameter automatic test
    Huang, Su-Juan
    Feng, Yu-Tian
    Zhang, Yu-Jian
    Chen, Quan-Lin
    Journal of Shanghai University, 2002, 6 (04):