Improved detection of small lung cancers with dual-energy subtraction chest radiography

被引:44
|
作者
Li, Feng [1 ,2 ]
Engelmann, Roger [1 ,2 ]
Doi, Kunio [1 ,2 ]
MacMahon, Heber [1 ,2 ]
机构
[1] Univ Chicago, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
diagnostic radiology; digital radiography; dual-energy subtraction radiography; lung neoplasms; observer performance study;
D O I
10.2214/AJR.07.2875
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to retrospectively evaluate whether the use of dual-energy subtraction chest radiographs can improve radiologists' performance for the detection of small previously missed lung cancers. MATERIALS AND METHODS. Dual-energy subtraction chest radiographs of 19 patients with previously missed nodular cancers, in which the radiology report did not mention a nodule that was visible in retrospect, were selected. Dual-energy subtraction radiographs of 19 patients with cancer and 16 patients without cancer were used for an observer study. Six radiologists indicated their confidence level regarding the presence of a lung cancer and, if they thought a cancer was present, also marked the most likely position for each lung, first using standard posteroanterior and lateral chest radiographs and then using both soft-tissue and bone dual-energy subtraction images along with standard radiographs. Receiver operating characteristic (ROC) curves were used to evaluate the observers' performance. The indicated locations of cancers and false-positives were also analyzed. RESULTS. The average area under the ROC curve (A(z)) value for the six radiologists was improved from 0.718 to 0.816, a statistically significant amount (p = 0.004), and the average sensitivity (correct localizations) for 19 previously missed cancers was also significantly improved from 40% to 59% (p = 0.008) with the aid of dual-energy subtraction images. The average number of false-positive (incorrect) localizations on 70 lungs was 10 without and nine with dual-energy subtraction images (p = 0.785). CONCLUSION. Dual-energy subtraction chest radiography has the potential to improve radiologists' performance for the detection of small missed lung cancers.
引用
收藏
页码:886 / 891
页数:6
相关论文
共 50 条
  • [31] Lung field segmenting in dual-energy subtraction chest x-ray images
    Alvarez, RE
    JOURNAL OF DIGITAL IMAGING, 2004, 17 (01) : 45 - 56
  • [32] Single exposure dual energy subtraction computed radiography of the chest for the assessment of nodule detection
    Hartman, TE
    Aughenbaugh, GL
    Harms, GF
    Sykes, AG
    Weaver, AL
    Hodge, D
    RADIOLOGY, 1998, 209P : 410 - 410
  • [33] Lung Field Segmenting in Dual-Energy Subtraction Chest X-ray Images
    Robert E. Alvarez
    Journal of Digital Imaging, 2004, 17 : 45 - 56
  • [34] Computerized Detection of Lung Nodules by Means of "Virtual Dual-Energy" Radiography
    Chen, Sheng
    Suzuki, Kenji
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (02) : 369 - 378
  • [35] Improved detection of coronary artery calcifications using dual energy subtraction radiography
    Lazebnik, R. S.
    Sachs, P. B.
    Gilkeson, R. C.
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [36] COMPARISON OF DUAL AND SINGLE EXPOSURE TECHNIQUES IN DUAL-ENERGY CHEST RADIOGRAPHY
    HO, JT
    KRUGER, RA
    SORENSON, JA
    MEDICAL PHYSICS, 1989, 16 (02) : 202 - 208
  • [37] SINGLE EXPOSURE DUAL-ENERGY SUBTRACTION RADIOGRAPHY OF THE UPPER AIRWAYS USING COMPUTED RADIOGRAPHY
    ODAGIRI, K
    FUJIWARA, T
    ANDOH, K
    KINNO, Y
    MATSUURA, H
    TSUKUDA, M
    ACTA RADIOLOGICA, 1992, 33 (03) : 281 - 283
  • [38] Comparison of dual energy subtraction chest radiography and traditional chest X-rays in the detection of pulmonary nodules
    Manji, Farheen
    Wang, Jiheng
    Norman, Geoff
    Wang, Zhou
    Koff, David
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (01) : 1 - 5
  • [39] SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING
    ERGUN, DL
    MISTRETTA, CA
    BROWN, DE
    BYSTRIANYK, RT
    SZE, WK
    KELCZ, F
    NAIDICH, DP
    RADIOLOGY, 1990, 174 (01) : 243 - 249
  • [40] DUAL-ENERGY CHEST RADIOGRAPHY - PHYSICAL PRINCIPLES AND CLINICAL POTENTIAL
    BARNES, GT
    FRASER, RG
    SANDERS, PC
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C389 - C389