Lateral flow nucleic acid biosensor for sensitive detection of microRNAs based on the dual amplification strategy of duplex-specific nuclease and hybridization chain reaction

被引:19
|
作者
Ying, Na [1 ,2 ]
Ju, Chuanjing [1 ,3 ,4 ]
Sun, Xiuwei [1 ,5 ]
Li, Letian [1 ]
Chang, Hongbiao [1 ,6 ]
Song, Guangping [1 ,7 ]
Li, Zhongyi [1 ]
Wan, Jiayu [1 ]
Dai, Enyong [8 ]
机构
[1] Acad Mil Med Sci, Inst Mil Vet, Changchun, Jilin, Peoples R China
[2] China Acad Fishery Sci, East China Sea Fisheries Res Inst, Shanghai, Peoples R China
[3] Gen Hosp FAW, Changchun, Jilin, Peoples R China
[4] Jilin Univ, Hosp 4, Changchun, Jilin, Peoples R China
[5] Jilin Agr Univ, Coll Anim Sci & Technol, Changchun, Jilin, Peoples R China
[6] Changchun Univ Sci & Technol, Sch Life Sci & Technol, Changchun, Jilin, Peoples R China
[7] Heilongjiang Bayi Agr Univ, Daqing, Peoples R China
[8] Jilin Univ, China Japan Union Hosp, Dept Oncol & Hematol, Changchun, Jilin, Peoples R China
来源
PLOS ONE | 2017年 / 12卷 / 09期
关键词
DNA DETECTION; QUANTIFICATION;
D O I
10.1371/journal.pone.0185091
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
MicroRNAs (miRNAs) constitute novel biomarkers for various diseases. Accurate and quantitative analysis of miRNA expression is critical for biomedical research and clinical theranostics. In this study, a method was developed for sensitive and specific detection of miRNAs via dual signal amplification based on duplex specific nuclease (DSN) and hybridization chain reaction (HCR). A reporter probe (RP), comprising recognition sequence (3' end modified with biotin) for a target miRNA of miR-21 and capture sequence (5' end modified with Fam) for HCR product, was designed and synthesized. HCR was initiated by partial sequence of initiator probe (IP), the other part of which can hybridize with capture sequence of RP, and was assembled by hairpin probes modified with biotin (H1-bio and H2-bio). A miR-21 triggered cyclical DSN cleavage of RP, which was immobilized to a streptavidin (SA) coated magnetic bead (MB). The released Fam labeled capture sequence then hybridized with the HCR product to generate a detectable dsDNA. This polymer was then dropped on lateral flow strip and positive result was observed. The proposed method allowed quantitative sequence-specific detection of miR-21 (with a detection limit of 2.1 fM, S/N = 3) in a dynamic range from 100 fM to 100 pM, with an excellent ability to discriminate differences in miRNAs. The method showed acceptable testing recoveries for the determination of miRNAs in serum.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Au nanoparticles/hollow molybdenum disulfide microcubes based biosensor for microRNA-21 detection coupled with duplex-specific nuclease and enzyme signal amplification
    Shuai, Hong-Lei
    Huang, Ke-Jing
    Chen, Ying-Xu
    Fang, Lin-Xia
    Jia, Meng-Pei
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 989 - 997
  • [42] Sensitive detection of DNA methyltransferase activity by transcription-mediated duplex-specific nuclease-assisted cyclic signal amplification
    Zhang, Yan
    Xu, Wen-jing
    Zeng, Ya-ping
    Zhang, Chun-yang
    CHEMICAL COMMUNICATIONS, 2015, 51 (73) : 13968 - 13971
  • [43] Backbone-modified molecular beacons for highly sensitive and selective detection of microRNAs based on duplex specific nuclease signal amplification
    Lin, Xiaoyan
    Zhang, Cheng
    Huang, Yishun
    Zhu, Zhi
    Chen, Xi
    Yang, Chaoyong James
    CHEMICAL COMMUNICATIONS, 2013, 49 (65) : 7243 - 7245
  • [44] Label-free fluorescence detection of circulating microRNAs based on duplex-specific nuclease-assisted target recycling coupled with rolling circle amplification
    Fan, Tingting
    Mao, Yu
    Liu, Feng
    Zhang, Wei
    Lin, Jin-Shun
    Yin, Jingxian
    Tan, Ying
    Huang, Xiaoting
    Jiang, Yuyang
    TALANTA, 2019, 200 : 480 - 486
  • [45] A signal-on homogeneous electrochemical biosensor for sequence-specific microRNA based on duplex-specific nuclease-assisted target recycling amplification
    Fu, Caili
    Liu, Chang
    Wang, Shaoyun
    Luo, Fang
    Lin, Zhenyu
    Chen, Guonan
    ANALYTICAL METHODS, 2016, 8 (39) : 7034 - 7039
  • [46] Electrochemical detection of microRNAs based on AuNPs/CNNS nanocomposite with Duplex-specific nuclease assisted target recycling to improve the sensitivity
    Ma, Xiangyu
    Xu, Haoran
    Qian, Kun
    Kandawa-Schulz, Martha
    Miao, Weimin
    Wang, Yihong
    TALANTA, 2020, 208
  • [47] Ultrasensitive lateral flow biosensor based on PtAu@CNTs nanocomposite catalytic chromogenic signal amplification strategy for the detection of nucleic acid
    Xu, Dongqing
    An, Xue
    Wang, Yuying
    Qian, Lisheng
    Qiu, Wanwei
    Zhang, Xueji
    Liu, Guodong
    ANALYTICA CHIMICA ACTA, 2023, 1260
  • [48] Ratiometric electrochemical biosensor based on hybridization chain reaction signal amplification for sensitive microRNA-155 detection
    Ma, Yan
    Li, Mengyao
    Zhang, Yuzhong
    ANALYTICAL METHODS, 2024, 16 (29) : 5032 - 5037
  • [49] Highly sensitive electrogenerated chemiluminescence biosensor based on hybridization chain reaction and amplification of gold nanoparticles for DNA detection
    Wang, Xiuzhong
    Ge, Lei
    Yu, Yanfei
    Dong, Shanshan
    Li, Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 942 - 948
  • [50] Facile detection of microRNA based on phosphorescence resonance energy transfer and duplex-specific nuclease-assisted signal amplification
    Yang, Jia-jia
    Zhang, Zhi-feng
    Yan, Gui-qin
    ANALYTICAL BIOCHEMISTRY, 2017, 539 : 127 - 133