Lateral flow nucleic acid biosensor for sensitive detection of microRNAs based on the dual amplification strategy of duplex-specific nuclease and hybridization chain reaction

被引:19
|
作者
Ying, Na [1 ,2 ]
Ju, Chuanjing [1 ,3 ,4 ]
Sun, Xiuwei [1 ,5 ]
Li, Letian [1 ]
Chang, Hongbiao [1 ,6 ]
Song, Guangping [1 ,7 ]
Li, Zhongyi [1 ]
Wan, Jiayu [1 ]
Dai, Enyong [8 ]
机构
[1] Acad Mil Med Sci, Inst Mil Vet, Changchun, Jilin, Peoples R China
[2] China Acad Fishery Sci, East China Sea Fisheries Res Inst, Shanghai, Peoples R China
[3] Gen Hosp FAW, Changchun, Jilin, Peoples R China
[4] Jilin Univ, Hosp 4, Changchun, Jilin, Peoples R China
[5] Jilin Agr Univ, Coll Anim Sci & Technol, Changchun, Jilin, Peoples R China
[6] Changchun Univ Sci & Technol, Sch Life Sci & Technol, Changchun, Jilin, Peoples R China
[7] Heilongjiang Bayi Agr Univ, Daqing, Peoples R China
[8] Jilin Univ, China Japan Union Hosp, Dept Oncol & Hematol, Changchun, Jilin, Peoples R China
来源
PLOS ONE | 2017年 / 12卷 / 09期
关键词
DNA DETECTION; QUANTIFICATION;
D O I
10.1371/journal.pone.0185091
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
MicroRNAs (miRNAs) constitute novel biomarkers for various diseases. Accurate and quantitative analysis of miRNA expression is critical for biomedical research and clinical theranostics. In this study, a method was developed for sensitive and specific detection of miRNAs via dual signal amplification based on duplex specific nuclease (DSN) and hybridization chain reaction (HCR). A reporter probe (RP), comprising recognition sequence (3' end modified with biotin) for a target miRNA of miR-21 and capture sequence (5' end modified with Fam) for HCR product, was designed and synthesized. HCR was initiated by partial sequence of initiator probe (IP), the other part of which can hybridize with capture sequence of RP, and was assembled by hairpin probes modified with biotin (H1-bio and H2-bio). A miR-21 triggered cyclical DSN cleavage of RP, which was immobilized to a streptavidin (SA) coated magnetic bead (MB). The released Fam labeled capture sequence then hybridized with the HCR product to generate a detectable dsDNA. This polymer was then dropped on lateral flow strip and positive result was observed. The proposed method allowed quantitative sequence-specific detection of miR-21 (with a detection limit of 2.1 fM, S/N = 3) in a dynamic range from 100 fM to 100 pM, with an excellent ability to discriminate differences in miRNAs. The method showed acceptable testing recoveries for the determination of miRNAs in serum.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Recent advances in duplex-specific nuclease-based signal amplification strategies for microRNA detection
    Wu, Yudong
    Cui, Shuang
    Li, Qian
    Zhang, Renshuai
    Song, Zhengming
    Gao, Yuanzhen
    Chen, Wujun
    Xing, Dongming
    Biosensors and Bioelectronics, 2020, 165
  • [22] Direct sensing of microRNAs based on magnetic bead-chemiluminescence platform and duplex-specific nuclease signal amplification
    Yang, Haowen
    He, Nongyue
    Li, Zhiyang
    deMello, Andrew
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [23] Duplex-specific nuclease-based electrochemical biosensor for the detection of microRNAs by conversion of homogeneous assay into surface-tethered electrochemical analysis
    Liu, Lin
    Deng, Dehua
    Wu, Daohong
    Hou, Weilin
    Wang, Lu
    Li, Ning
    Sun, Zhifang
    Analytica Chimica Acta, 2021, 1149
  • [24] Electrochemical Biosensors for MicroRNA Detection using Duplex-Specific Nuclease based Signal Amplification Strategies
    Wu, Daohong
    Yi, Xinyao
    Xia, Ning
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (12): : 12136 - 12148
  • [25] Duplex-specific nuclease-based electrochemical biosensor for the detection of microRNAs by conversion of homogeneous assay into surface-tethered electrochemical analysis
    Liu, Lin
    Deng, Dehua
    Wu, Daohong
    Hou, Weilin
    Wang, Lu
    Li, Ning
    Sun, Zhifang
    ANALYTICA CHIMICA ACTA, 2021, 1149
  • [26] Highly sensitive microRNA detection by a duplex-specific nuclease amplification triggered three-dimensional DNA machine
    Chen, Chaohui
    He, Rongxiang
    Liu, Xiaoyun
    Zhang, Zhengtao
    Chen, Long
    ANALYTICAL METHODS, 2021, 13 (47) : 5694 - 5699
  • [27] Highly Sensitive and Selective Strategy for MicroRNA Detection Based on WS2 Nanosheet Mediated Fluorescence Quenching and Duplex-Specific Nuclease Signal Amplification
    Xi, Qiang
    Zhou, Dian-Ming
    Kan, Ying-Ya
    Ge, Jia
    Wu, Zhen-Kun
    Yu, Ru-Qin
    Jiang, Jian-Hui
    ANALYTICAL CHEMISTRY, 2014, 86 (03) : 1361 - 1365
  • [28] Colorimetric detection of sequence-specific microRNA based on duplex-specific nuclease-assisted nanoparticle amplification
    Wang, Qian
    Li, Ru-Dong
    Yin, Bin-Cheng
    Ye, Bang-Ce
    ANALYST, 2015, 140 (18) : 6306 - 6312
  • [29] Ratiometric Fluorescent Biosensor Based on Self-Assembled Fluorescent Gold Nanoparticles and Duplex-Specific Nuclease-Assisted Signal Amplification for Sensitive Detection of Exosomal miRNA
    Sun, Zhiwei
    Li, Juan
    Yang, Yufei
    Tong, Yao
    Li, Hui
    Wang, Chuanxin
    Du, Lutao
    Jiang, Yanyan
    BIOCONJUGATE CHEMISTRY, 2022, 33 (09) : 1698 - 1706
  • [30] An ultrasensitive electrochemical biosensor for detection of microRNA-21 based on redox reaction of ascorbic acid/iodine and duplex-specific nuclease assisted target recycling
    Wang, Jin
    Lu, Jian
    Dong, Shuaibing
    Zhu, Nuanfei
    Gyimah, Eric
    Wang, Kun
    Li, Yong
    Zhang, Zhen
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 81 - 87