Lateral flow nucleic acid biosensor for sensitive detection of microRNAs based on the dual amplification strategy of duplex-specific nuclease and hybridization chain reaction

被引:19
|
作者
Ying, Na [1 ,2 ]
Ju, Chuanjing [1 ,3 ,4 ]
Sun, Xiuwei [1 ,5 ]
Li, Letian [1 ]
Chang, Hongbiao [1 ,6 ]
Song, Guangping [1 ,7 ]
Li, Zhongyi [1 ]
Wan, Jiayu [1 ]
Dai, Enyong [8 ]
机构
[1] Acad Mil Med Sci, Inst Mil Vet, Changchun, Jilin, Peoples R China
[2] China Acad Fishery Sci, East China Sea Fisheries Res Inst, Shanghai, Peoples R China
[3] Gen Hosp FAW, Changchun, Jilin, Peoples R China
[4] Jilin Univ, Hosp 4, Changchun, Jilin, Peoples R China
[5] Jilin Agr Univ, Coll Anim Sci & Technol, Changchun, Jilin, Peoples R China
[6] Changchun Univ Sci & Technol, Sch Life Sci & Technol, Changchun, Jilin, Peoples R China
[7] Heilongjiang Bayi Agr Univ, Daqing, Peoples R China
[8] Jilin Univ, China Japan Union Hosp, Dept Oncol & Hematol, Changchun, Jilin, Peoples R China
来源
PLOS ONE | 2017年 / 12卷 / 09期
关键词
DNA DETECTION; QUANTIFICATION;
D O I
10.1371/journal.pone.0185091
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
MicroRNAs (miRNAs) constitute novel biomarkers for various diseases. Accurate and quantitative analysis of miRNA expression is critical for biomedical research and clinical theranostics. In this study, a method was developed for sensitive and specific detection of miRNAs via dual signal amplification based on duplex specific nuclease (DSN) and hybridization chain reaction (HCR). A reporter probe (RP), comprising recognition sequence (3' end modified with biotin) for a target miRNA of miR-21 and capture sequence (5' end modified with Fam) for HCR product, was designed and synthesized. HCR was initiated by partial sequence of initiator probe (IP), the other part of which can hybridize with capture sequence of RP, and was assembled by hairpin probes modified with biotin (H1-bio and H2-bio). A miR-21 triggered cyclical DSN cleavage of RP, which was immobilized to a streptavidin (SA) coated magnetic bead (MB). The released Fam labeled capture sequence then hybridized with the HCR product to generate a detectable dsDNA. This polymer was then dropped on lateral flow strip and positive result was observed. The proposed method allowed quantitative sequence-specific detection of miR-21 (with a detection limit of 2.1 fM, S/N = 3) in a dynamic range from 100 fM to 100 pM, with an excellent ability to discriminate differences in miRNAs. The method showed acceptable testing recoveries for the determination of miRNAs in serum.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Short-probe-based duplex-specific nuclease signal amplification strategy enables imaging of endogenous microRNAs in living cells with ultrahigh specificity
    Ma, Yingjun
    Chen, Jun
    Chen, Danping
    Xu, Yuzhi
    Zhang, Li
    Dai, Zong
    Zou, Xiaoyong
    TALANTA, 2018, 186 : 256 - 264
  • [32] Hybridization chain reaction assisted terahertz metamaterial biosensor for highly sensitive detection of microRNAs
    Chen, Jie
    Hu, Fangrong
    Lin, Shangjun
    Song, Zihang
    Duan, Zhitao
    Zhang, Longhui
    Jiang, Mingzhu
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 307
  • [33] A microfluidic-based chemiluminescence biosensor for sensitive multiplex detection of exosomal microRNAs based on hybridization chain reaction
    Peng, Jie
    Li, Baicheng
    Ma, Zhiyuan
    Qiu, Zhengxuan
    Hu, Hong
    Jiang, Yuyang
    Gao, Dan
    TALANTA, 2025, 281
  • [34] Ratiometric Electrochemiluminescent/Electrochemical Strategy for Sensitive Detection of MicroRNA Based on Duplex-Specific Nuclease and Multilayer Circuit of Catalytic Hairpin Assembly
    Zhu, Liping
    Zhang, Mengqian
    Ye, Jing
    Yan, Mengxia
    Zhu, Qiuju
    Huang, Jianshe
    Yang, Xiurong
    ANALYTICAL CHEMISTRY, 2020, 92 (12) : 8614 - 8622
  • [35] A gold nanoparticle-based colorimetric strategy coupled to duplex-specific nuclease signal amplification for the determination of microRNA
    Shi, Hai-yan
    Yang, Lang
    Zhou, Xiao-yu
    Bai, Jie
    Gao, Jie
    Jia, Hong-xia
    Li, Qing-gui
    MICROCHIMICA ACTA, 2017, 184 (02) : 525 - 531
  • [36] A gold nanoparticle-based colorimetric strategy coupled to duplex-specific nuclease signal amplification for the determination of microRNA
    Hai-yan Shi
    Lang Yang
    Xiao-yu Zhou
    Jie Bai
    Jie Gao
    Hong-xia Jia
    Qing-gui Li
    Microchimica Acta, 2017, 184 : 525 - 531
  • [37] A multiplex and fast detection platform for microRNAs based on a self-priming microfluidic chip and duplex-specific nuclease
    Zou, Zheyu
    Liu, Yuanhui
    Xia, Liping
    Hu, Zhenming
    Yin, Juxin
    Mu, Ying
    ANALYST, 2021, 146 (02) : 628 - 635
  • [38] Nanopore-Based Electrochemiluminescence for Detection of MicroRNAs via Duplex-Specific Nuclease-Assisted Target Recycling
    Huo, Xiao-Lei
    Yang, Hui
    Zhao, Wei
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (38) : 33360 - 33367
  • [39] Lateral flow colorimetric biosensor for detection of Vibrio parahaemolyticus based on hybridization chain reaction and aptamer
    Na Ying
    Yuan Wang
    Xuefeng Song
    Liguo Yang
    Bo Qin
    Yanqing Wu
    Wenhong Fang
    Microchimica Acta, 2021, 188
  • [40] Lateral flow colorimetric biosensor for detection of Vibrio parahaemolyticus based on hybridization chain reaction and aptamer
    Ying, Na
    Wang, Yuan
    Song, Xuefeng
    Yang, Liguo
    Qin, Bo
    Wu, Yanqing
    Fang, Wenhong
    MICROCHIMICA ACTA, 2021, 188 (11)