Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
|
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 50 条
  • [41] Single breath-hold left ventricular volume measurement by 0.3-sec turbo fast low-angle shot MR imaging
    Motooka, M
    Matsuda, T
    Kida, M
    Inoue, H
    Hayashi, K
    Takahashi, T
    Sasayama, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) : 1645 - 1649
  • [42] Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function
    Eberle, Holger C.
    Nassenstein, Kai
    Jensen, Christoph J.
    Schlosser, Thomas
    Sabin, Georg V.
    Naber, Christoph K.
    Bruder, Oliver
    EUROPEAN RADIOLOGY, 2010, 20 (01) : 73 - 80
  • [43] Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function
    Holger C. Eberle
    Kai Nassenstein
    Christoph J. Jensen
    Thomas Schlosser
    Georg V. Sabin
    Christoph K. Naber
    Oliver Bruder
    European Radiology, 2010, 20 : 73 - 80
  • [44] Left ventricular pseudoaneurysm: Diagnosis by cine magnetic resonance imaging
    Frances, CD
    Shlipak, MG
    Grady, D
    CARDIOLOGY, 1999, 92 (03) : 217 - 219
  • [45] A single breath-hold for analysis of systolic and diastolic cardiac function: TGRAPPA accelerated multiplanar Cine MR imaging at 3 Tesla
    Torleif A Sandner
    Daniel Theisen
    Kerstin U Bauner
    Konstantin Nikolaou
    Maximilian F Reiser
    Bernd J Wintersperger
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [46] Cine MR imaging after myocardial infarction - Assessment and follow-up of regional and global left ventricular function
    Sandstede, JJW
    Lipke, C
    Kenn, W
    Beer, M
    Pabst, T
    Hahn, D
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (06): : 435 - 440
  • [47] Cine MR imaging after myocardial infarction – Assessment and follow-up of regional and global left ventricular function
    Joern J.W. Sandstede
    Claudia Lipke
    Werner Kenn
    Meinrad Beer
    Thomas Pabst
    Dietbert Hahn
    The International Journal of Cardiac Imaging, 1999, 15 : 435 - 440
  • [48] Single breath-hold CINE imaging with combined simultaneous multislice and region-optimized virtual coils
    Kim, Daeun
    Coll-Font, Jaume
    Lobos, Rodrigo A.
    Stab, Daniel
    Pang, Jianing
    Foster, Anna
    Garrett, Thomas
    Bi, Xiaoming
    Speier, Peter
    Haldar, Justin P.
    Nguyen, Christopher
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (01) : 222 - 230
  • [49] Fast automated assessment of regional left ventricular function from tagged cardiac images by harmonic phase magnetic resonance imaging
    Garot, J
    Bluemke, DA
    Osman, NF
    Rochitte, CE
    McVeigh, ER
    Zerhouni, EA
    Prince, JL
    Lima, JAC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 464A - 464A
  • [50] ASSESSMENT OF REGIONAL LEFT-VENTRICULAR FUNCTION BY MAGNETIC-RESONANCE
    UNDERWOOD, SR
    REES, RSO
    SAVAGE, PE
    KLIPSTEIN, RH
    FIRMIN, DN
    FOX, KM
    POOLEWILSON, PA
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1986, 56 (04): : 334 - 340