Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
|
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 50 条
  • [21] Breath-hold dobutamine magnetic resonance myocardial tagging: Normal left ventricular response
    Power, TP
    Kramer, CM
    Shaffer, AL
    Theobald, TM
    Petruolo, S
    Reichek, N
    Rogers, WJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (09): : 1203 - 1207
  • [22] Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction
    Longere, Benjamin
    Chavent, Marc-Henry
    Coisne, Augustin
    Gkizas, Christos
    Pagniez, Julien
    Simeone, Arianna
    Silvestri, Valentina
    Schmidt, Michaela
    Forman, Christoph
    Montaigne, David
    Pontana, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (05) : 297 - 303
  • [23] Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold
    Hori, Y
    Yamada, N
    Higashi, M
    Hirai, N
    Nakatani, S
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) : 439 - 450
  • [24] The effects of flip angle and gadolinium contrast agent on single breath-hold compressed sensing cardiac magnetic resonance cine for biventricular global strain assessment
    Wang, Fuyan
    Pu, Cailing
    Ma, Siying
    Zhou, Junjie
    Jiang, Yangyang
    Yu, Feidan
    Zhang, Shuheng
    Wu, Yan
    Zhang, Lingjie
    He, Chengbin
    Hu, Hongjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [25] Assessment of voluntary deep inspiration breath-hold with CINE imaging for breast radiotherapy
    Estoesta, Reuben Patrick
    Attwood, Lani
    Naehrig, Diana
    Claridge-Mackonis, Elizabeth
    Odgers, David
    Martin, Darren
    Pham, Melissa
    Toohey, Joanne
    Carroll, Susan
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (05) : 689 - 694
  • [26] High temporal resolution breath-hold cine magnetic resonance imaging correlates with tissue Doppler imaging in revealing ventricular dssynchrony in heart failure.
    Alvergue, J
    Dinh, HV
    Fonseca, C
    Child, J
    Valderrabano, M
    Shivkumar, K
    Fonarow, GC
    Finn, JP
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S124 - S124
  • [27] Assessment of myocardial function with interactive non-breath-hold real-time MR imaging:: Comparison with echocardiography and breath-hold cine MR imaging
    Kühl, HP
    Spuentrup, E
    Wall, A
    Franke, A
    Schröder, J
    Heussen, N
    Hanrath, P
    Günther, RW
    Buecker, A
    RADIOLOGY, 2004, 231 (01) : 198 - 207
  • [28] An Automated Evaluation of Regional Left Ventricular Function on Cine Magnetic Resonance Images
    El Berbari, R.
    Kachenoura, N.
    Redheuil, A.
    Herment, A.
    Bloch, I.
    Mousseaux, E.
    Frouin, F.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 777 - +
  • [29] Effect of variable breath-hold positions during cardiac magnetic resonance on measures of left ventricular mechanics
    Sean M Hamlet
    Gregory J Wehner
    Jonathan D Suever
    David Powell
    Christopher M Haggerty
    Linyuan Jing
    Xiaodong Zhong
    Frederick H Epstein
    Brandon K Fornwalt
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [30] Magnetic Resonance Imaging in Breath-Hold Divers with Cerebral Decompression Sickness
    Matsuo, Ryu
    Kamouchi, Masahiro
    Arakawa, Shuji
    Furuta, Yoshihiko
    Kanazawa, Yuka
    Kitazono, Takanari
    CASE REPORTS IN NEUROLOGY, 2014, 6 (01): : 23 - 27