Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
|
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 50 条
  • [31] Comparison of a Multi-Breath-Hold and a Single Breath-Hold Cine Imaging Approach for 4D Guide-Point Modeling of the Left Ventricle
    Heilmaier, C.
    Schlosser, T.
    Bruder, O.
    Nassenstein, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (09): : 780 - 787
  • [32] Assessment of coronary bypass patency with breath-hold magnetic resonance angiography
    Ambrosi, P
    Gelisse, R
    Bruneau, P
    Habib, G
    Bretelle, C
    Luccioni, R
    Bernard, PJ
    PRESSE MEDICALE, 1996, 25 (38): : 1873 - 1875
  • [33] Breath-hold cardiac MR imaging: Improvements in image quality with fast SE, TurboSTIR, HASTE, and breath-hold cine MR angiography compared with standard techniques
    Hartnell, GG
    Charlamb, M
    Cohen, MC
    Saouaf, R
    Simonetti, OP
    Finn, JP
    RADIOLOGY, 1996, 201 : 788 - 788
  • [34] Artifact-free black-blood cine cardiac imaging in a single breath-hold
    Fahmy, Ahmed S.
    Pan, Li
    Osman, Nael F.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (10) : 1303 - 1310
  • [35] Comparison of left and right ventricular ejection and filling parameters by fast cine MR imaging in breath-hold technique: Clinical study of 42 patients with cardiomyopathy and coronary heart disease.
    Rominger, MB
    Bachmann, GF
    Geuer, M
    Puzik, M
    Ricken, WW
    Rau, WS
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (06): : 534 - 541
  • [36] T2 weighted liver Magnetic Resonance imaging using functional residual capacity breath-hold with multi breath-hold
    Tabuchi, A.
    Katsuda, T.
    Gotanda, R.
    Gotanda, T.
    Yamamoto, K.
    Mitani, M.
    Takeda, Y.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1598 - 1602
  • [37] SINGLE BREATH-HOLD PULMONARY MAGNETIC-RESONANCE ANGIOGRAPHY - OPTIMIZATION AND COMPARISON OF 3 IMAGING STRATEGIES
    RUBIN, GD
    HERFKENS, RJ
    PELC, NJ
    FOO, TKF
    NAPEL, S
    SHIMAKAWA, A
    STEINER, RM
    BERGIN, CJ
    INVESTIGATIVE RADIOLOGY, 1994, 29 (08) : 766 - 772
  • [38] Validation and application of single breath-hold cine cardiac MR for ventricular function assessment in children with congenital heart disease at rest and during adenosine stress
    Taylor, AM
    Dymarkowski, S
    De Meerleer, K
    Hamaekers, P
    Gewillig, M
    Mertens, L
    Bogaert, J
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) : 743 - 751
  • [39] Clinical Determinants of Global and Regional Left Ventricular Systolic Function by Cardiac Magnetic Resonance Imaging: The Jackson Heart Study
    Balfour, Pelbreton C.
    Musani, Solomon K.
    Williams, Renaldo
    Samdarshi, Tandaw S.
    Carr, Jeffrey
    Hundley, William C.
    Terry, Greg
    Taylor, Herman A.
    Ramachandran, Vasan S.
    Fox, Ervin
    CIRCULATION, 2012, 126 (21)
  • [40] Left ventricular ejection fraction measurement: Breath-hold cine MR with automatic cardiac analysis and radionuclide ventriculography
    Liu, Y
    Sampson, C
    Shimakawa, A
    Wann, LS
    RADIOLOGY, 1996, 201 : 1495 - 1495