New method to measure coronary velocity and coronary flow reserve

被引:6
|
作者
Zhang, Z. -D. [1 ]
Svendsen, M. [1 ]
Choy, J. S. [1 ]
Sinha, A. K. [2 ]
Huo, Y. [1 ]
Yoshida, K. [1 ]
Molloi, S. [3 ]
Kassab, G. S. [1 ,2 ]
机构
[1] Indiana Univ, Purdue Univ, Dept Biomed Engn, Indianapolis, IN 46204 USA
[2] Indiana Univ, Purdue Univ, Dept Med, Indianapolis, IN 46204 USA
[3] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92717 USA
关键词
catheter; conductance; DIGITAL-SUBTRACTION-ANGIOGRAPHY; BLOOD-FLOW; IMPEDANCE CATHETER; DOPPLER VELOCITY; LUMEN AREA; THERMODILUTION; VALIDATION; QUANTIFICATION; INJECTIONS; MODEL;
D O I
10.1152/ajpheart.00080.2011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21-H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.-Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline injection between two pairs of electrodes (known distance) on a conductance catheter during a routine saline injection without the need for reference flow. In vitro validation was made in the velocity range of 5 to 70 cm/s in reference to the volume collection method. In 10 swine, velocity measurements were compared with those from a flow probe in coronary arteries at different CFR attained by microsphere embolization. In vitro, the mean difference between the proposed method and volume collection was 0.7 +/- 1.34 cm/s for steady flow and -0.77 +/- 2.22 cm/s for pulsatile flow. The mean difference between duplicate measurements was 0 +/- 1.4 cm/s. In in vivo experiments, the flow (product of velocity and lumen cross-sectional area that is also measured by the conductance catheter) was determined in both normal and stenotic vessels and the mean difference between the proposed method and flow probe was -1 +/- 12 ml/min (flow ranged from 10 to 130 ml/min). For CFR, the mean difference between the two methods was 0.06 +/- 0.28 (range of 1 to 3). Our results demonstrate the reproducibility and accuracy of velocity and CFR measurements with a conductance catheter by use of a standard saline injection. The ability of the combined measurement of coronary lumen area (as previously validated) and current velocity and CFR measurements provides an integrative diagnostic tool for interventional cardiology.
引用
收藏
页码:H21 / H28
页数:8
相关论文
共 50 条
  • [31] Role of variability in microvascular resistance on fractional flow reserve and coronary blood flow velocity reserve in intermediate coronary lesions
    Meuwissen, M
    Chamuleau, SAJ
    Siebes, M
    Schotborgh, CE
    Koch, KT
    de Winter, RJ
    Bax, M
    de Jong, A
    Spaan, JAE
    Piek, JJ
    CIRCULATION, 2001, 103 (02) : 184 - 187
  • [32] Acute effects of nicotine content in cigarettes on coronary flow velocity and coronary flow reserve in men
    Tanaka, T
    Oka, Y
    Tawara, I
    Sada, T
    Kira, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10): : 1275 - +
  • [33] USE OF A NEW STEERABLE DOPPLER CORONARY CATHETER TO SUBSELECTIVELY MEASURE CORONARY BLOOD-FLOW VELOCITY
    SIBLEY, DH
    WHITLOW, PL
    MILLAR, H
    HARTLEY, CJ
    CIRCULATION, 1985, 72 (04) : 20 - 20
  • [34] Diastolic fractional flow reserve to assess the functional severity of moderate coronary artery stenoses - Comparison with fractional flow reserve and coronary flow velocity reserve
    Abe, M
    Tomiyama, H
    Yoshida, H
    Doba, N
    CIRCULATION, 2000, 102 (19) : 2365 - 2370
  • [35] Coronary Velocity Flow Reserve Is Affected by Coronary Calcification in Asymptomatic Patients With Mild Coronary Artery Disease
    Tsiapras, Dimitrios
    Mastorakou, Irene
    Vartela, Vasiliki
    Karapanagiotou, Olga
    Kyrzopoulos, Stamatis
    Katsilouli, Spyridoula
    Voudris, Vassilis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A281 - A281
  • [36] Coronary flow velocity reserve in three major coronary arteries by transthoracic echocardiography for the functional assessment of coronary artery disease: a comparison with fractional flow reserve
    Wada, Teruaki
    Hirata, Kumiko
    Shiono, Yasutsugu
    Orii, Makoto
    Shimamura, Kunihiro
    Ishibashi, Kohei
    Tanimoto, Takashi
    Yamano, Takashi
    Ino, Yasushi
    Kitabata, Hironori
    Yamaguchi, Tomoyuki
    Kubo, Takashi
    Imanishi, Toshio
    Akasaka, Takashi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (04) : 399 - 408
  • [37] Non-invasive assessment of coronary flow velocity reserve: A new method using transthoracic Doppler echocardiography
    Yang Ya
    Thomas Bartel
    Holger Eggebrecht
    Loredana Latina
    Clemems von Birgelen
    Guido Caspari
    Wang Xinfang
    Raimund Erbel
    Current Medical Science, 2002, 22 (2) : 158 - 163
  • [38] First results of a new method for angiographic calculation of coronary flow reserve
    Rittger, Harald
    Kuper, Asher
    Sinha, Anil
    Schmitt, Martin
    Jakob, Axel
    Brachmann, Johannes
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 21L - 21L
  • [39] Non-invasive Assessment of Coronary Flow Velocity Reserve: A New Method Using Transthoracic Doppler Echocardiography
    杨娅
    王新房
    Thomas Bartel
    Holger Eggebrecht
    Loredana Latina
    Clemems von Birgelen
    Guido Caspari
    Raimund Erbel
    Journal of Huazhong University of Science and Technology(Med, 2002, (02) : 158 - 163
  • [40] The functional and coronary anatomic correlates of coronary flow velocity reserve during stress echocardiography
    Ciampi, Q.
    Zagatina, A.
    Cortigiani, L.
    Gaibazzi, N.
    Borguezan Daros, C.
    Zhuravskaya, N.
    Wierzbowska-Drabik, K.
    De Castro E Silva Pretto, J. L.
    D'Andrea, A.
    Djordjevic-Dikic, A.
    Simova, I.
    Boshchenko, A.
    Amor, M.
    Merlo, P. B.
    Picano, E.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3044 - 3044