New method to measure coronary velocity and coronary flow reserve

被引:6
|
作者
Zhang, Z. -D. [1 ]
Svendsen, M. [1 ]
Choy, J. S. [1 ]
Sinha, A. K. [2 ]
Huo, Y. [1 ]
Yoshida, K. [1 ]
Molloi, S. [3 ]
Kassab, G. S. [1 ,2 ]
机构
[1] Indiana Univ, Purdue Univ, Dept Biomed Engn, Indianapolis, IN 46204 USA
[2] Indiana Univ, Purdue Univ, Dept Med, Indianapolis, IN 46204 USA
[3] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92717 USA
关键词
catheter; conductance; DIGITAL-SUBTRACTION-ANGIOGRAPHY; BLOOD-FLOW; IMPEDANCE CATHETER; DOPPLER VELOCITY; LUMEN AREA; THERMODILUTION; VALIDATION; QUANTIFICATION; INJECTIONS; MODEL;
D O I
10.1152/ajpheart.00080.2011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21-H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.-Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline injection between two pairs of electrodes (known distance) on a conductance catheter during a routine saline injection without the need for reference flow. In vitro validation was made in the velocity range of 5 to 70 cm/s in reference to the volume collection method. In 10 swine, velocity measurements were compared with those from a flow probe in coronary arteries at different CFR attained by microsphere embolization. In vitro, the mean difference between the proposed method and volume collection was 0.7 +/- 1.34 cm/s for steady flow and -0.77 +/- 2.22 cm/s for pulsatile flow. The mean difference between duplicate measurements was 0 +/- 1.4 cm/s. In in vivo experiments, the flow (product of velocity and lumen cross-sectional area that is also measured by the conductance catheter) was determined in both normal and stenotic vessels and the mean difference between the proposed method and flow probe was -1 +/- 12 ml/min (flow ranged from 10 to 130 ml/min). For CFR, the mean difference between the two methods was 0.06 +/- 0.28 (range of 1 to 3). Our results demonstrate the reproducibility and accuracy of velocity and CFR measurements with a conductance catheter by use of a standard saline injection. The ability of the combined measurement of coronary lumen area (as previously validated) and current velocity and CFR measurements provides an integrative diagnostic tool for interventional cardiology.
引用
收藏
页码:H21 / H28
页数:8
相关论文
共 50 条
  • [21] Coronary flow velocity reserve in obesity: new evidence of the relationship between inflammation and coronary microvascular function
    Tona, F.
    Serra, R.
    Di Ascenzo, L.
    Osto, E.
    Scarda, A.
    Corbetti, F.
    Foletto, M.
    Fabris, R.
    Iliceto, S.
    Vettor, R.
    EUROPEAN HEART JOURNAL, 2010, 31 : 998 - 999
  • [22] CLINICAL USEFULNESS OF MEASURING CORONARY FLOW VELOCITY/CORONARY FLOW VELOCITY RESERVE ASSESSED BY TRANSTHORACIC DOPPLER ECHOCARDIOGRAPHY
    Takeuchi, Masaaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 : S19 - S19
  • [23] CORONARY FLOW RESERVE AS A PHYSIOLOGIC MEASURE OF STENOSIS SEVERITY
    GOULD, KL
    KIRKEEIDE, RL
    BUCHI, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) : 459 - 474
  • [24] Effect of coronary calcification on coronary flow velocity reserve in mild - moderate coronary artery disease
    Tsiapras, D.
    Mastorakou, I.
    Vartela, V.
    Karapanagiotou, O.
    Kyrzopoulos, S.
    Katsilouli, S.
    Voudris, V.
    EUROPEAN HEART JOURNAL, 2009, 30 : 456 - 457
  • [25] Nitroglycerin withdrawal attenuates coronary flow velocity reserve
    nishimura, Kazuhisa
    Okayama, Hideki
    Saito, Makoto
    Uetani, Teruyosi
    Inaba, Shinnji
    Nagai, Takayuki
    Kurata, Akira
    Ogimoto, Akiyoshi
    Outsuka, Tomoaki
    Higaki, Jitsuo
    CIRCULATION, 2006, 114 (18) : 457 - 457
  • [26] The beneficial effect of pioglitazone on coronary flow velocity reserve
    Hiura, Yoshikazu
    Takeuchi, Masaaki
    Nagakura, Toshiki
    Nakai, Hiromi
    Nishikage, Tomoko
    Otani, Shinichiro
    DIABETES, 2008, 57 : A625 - A625
  • [27] Experimental hyperhomocysteinemia impairs coronary flow velocity reserve
    Yamashita, K
    Tasaki, H
    Nagai, Y
    Suzuka, H
    Nihei, S
    Kobayashi, K
    Horiuchi, M
    Nakashima, Y
    Adachi, T
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (02) : 163 - 169
  • [28] Coronary flow velocity reserve in patients with ischemic stroke
    Nakajima, Makoto
    Doi, Hideki
    Hirano, Teruyuki
    Tanaka, Yuko
    Uchino, Makoto
    MEDICAL SCIENCE MONITOR, 2009, 15 (08): : CR383 - CR388
  • [29] Validation of pressure-derived coronary flow reserve as an estimate of Doppler flow velocity and thermodilution derived coronary flow reserve
    van Lavieren, Martijn A.
    van de Hoef, Tim P.
    Echavarria-Pinto, Mauro
    Escaned, Javier
    Piek, Jan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B97 - B97
  • [30] Discordance of Coronary Flow Velocity Reserve With Fractional Flow Reserve Originates From Microvascular Involvement in Coronary Artery Disease
    van de Hoef, Tim P.
    van Lavieren, Martijn A.
    Damman, Peter
    Chamuleau, Steven A.
    Voskuil, Michiel
    Henriques, Jose P.
    Koch, Karel T.
    Spaan, Jos A.
    de Winter, Robbert J.
    Siebes, Maria
    Tijssen, Jan G.
    Meuwissen, M.
    Piek, Jan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B192 - B192