In vitro and in vivo characterisation of biodegradable polymer-based drug-eluting stent

被引:19
|
作者
Yazdani, Saami K. [1 ]
Vorpahl, Marc [1 ]
Nakano, Masataka [1 ]
Su, Shih-Horng [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
机构
[1] CVPath Inst Inc, Gaithersburg, MD 20878 USA
[2] Biosensors Int, Singapore, Singapore
关键词
drug-eluting stents; bio-erodible polymer; SEM; in vivo; in vitro; PLA; CORONARY-ARTERY; DURABLE POLYMER; IMPLANTATION; THROMBOSIS;
D O I
10.4244/EIJV7I7A131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The objective of this study was to investigate the structural integrity and early vascular response of a polylactic acid-coated (i.e., biodegradable polymer) coronary drug-eluting stent (DES) (BioMatrix (TM); Biosensors International, Singapore) to three currently marketed FDA/CE- mark approved non-erodible polymer-coated DES in a porcine model. Methods and results: BioMatrix (TM), XIENCE V (TM) (Abbott Vascular, Santa Clara, CA, USA), TAXUS (R) Liberte (TM) (Boston Scientific, Natick, MA, USA), and Cypher SELECT (TM) (Cordis, Johnson & Johnson, Miami, FL, USA) stems were implanted in pig coronaries for seven days. Polymer integrity was assessed by scanning electron microscopy (SEM) following tissue digestion. In vitro expansion of the BioMatrix (TM) was also performed. SEM analysis of in vivo stents demonstrated polymer defects on the abluminal surface of all DES including polymer cracking (BioMatrix (TM)), bridging (TAXUS Liberte (TM)), round-small defects (Cypher SELECT (TM)), and flaking (XIENCE V (TM)). Histologically, the myocardium revealed no evidence of acute myocardial infarction or microscopic scarring, moreover all intramyocardial vessels were found to be patent with no evidence of emboli. In vitro results demonstrated greater BioMatrix (TM) polymer cracking and lifting. Conclusions: These results illustrate the presence of polymer defects in all DES (TAXUS Liberte (TM), Cypher SELECT (TM), XIENCE V (TM), BioMatrix (TM)) implanted seven-days in pigs, with absence of myocardial damage in this small number of samples. Polymer coating irregularity was greater in BioMatrix (TM) stent expanded in vitro as compared to in vivo, suggesting simulated benchtop deployment induces greater damage to the biodegradable polymer coating than in vivo deployment in healthy porcine coronary arteries.
引用
收藏
页码:835 / 843
页数:9
相关论文
共 50 条
  • [41] Comparison of Vascular Responses Following New-Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model
    Nakazawa, Gaku
    Torii, Sho
    Ijichi, Takeshi
    Nagamatsu, Hirofumi
    Ohno, Yohei
    Kurata, Fumi
    Yoshikawa, Ayako
    Nakano, Masataka
    Shinozaki, Norihiko
    Yoshimachi, Fuminobu
    Ikari, Yuji
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (10):
  • [42] Angiographic Outcomes With Biodegradable Polymer and Permanent Polymer Drug-Eluting Stents
    Kufner, Sebastian
    Massberg, Steffen
    Dommasch, Michael
    Byrne, Robert A.
    Tiroch, Klaus
    Ranftl, Sabine
    Fusaro, Massimiliano
    Schoemig, Albert
    Kastrati, Adnan
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 161 - 166
  • [43] Combining mathematical modelling with in vitro experiments to predict in vivo drug-eluting stent performance
    McKittrick, Craig M.
    McKee, Sean
    Kennedy, Simon
    Oldroyd, Keith
    Wheel, Marcus
    Pontrelli, Giuseppe
    Dixon, Simon
    McGinty, Sean
    McCormick, Christopher
    JOURNAL OF CONTROLLED RELEASE, 2019, 303 : 151 - 161
  • [44] Endothelial cell recovery between comparator polymer-based drug-eluting stents
    Joner, Michael
    Nakazawa, Gaku
    Finn, Aloke V.
    Quee, Shawn Chin
    Coleman, Leslie
    Acampado, Eduardo
    Wilson, Patricia S.
    Skorija, Kristi
    Cheng, Qi
    Xu, Xin
    Gold, Herman K.
    Kolodgie, Frank D.
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) : 333 - 342
  • [45] Safety evaluation of the biodegradable polymer-based sirolimus-eluting stent with faster drug eluting rate and polymer absorption kinetics in complex patient and lesion subgroup
    Sida Jia
    Changdong Guan
    Jinqing Yuan
    Runlin Gao
    Bo Xu
    中国循环杂志, 2018, (S1) : 136 - 136
  • [46] Repeated drug-eluting stent implantation for drug-eluting stent restenosis: The same or a different stent
    Cosgrave, John
    Melzi, Gloria
    Corbett, Simon
    Biondi-Zoccai, Giuseppe G. L.
    Babic, Rade
    Airoldi, Flavio
    Chieffo, Alaide
    Sangiorgi, Giuseppe M.
    Montorfano, Matteo
    Michev, Iassen
    Carlino, Mauro
    Colombo, Antonio
    AMERICAN HEART JOURNAL, 2007, 153 (03) : 354 - 359
  • [47] Repeat drug-eluting stent implantation for drug-eluting stent restenosis: The same or a different stent
    Cosgrave, John
    Melzi, Gloria
    Corbett, Simon
    Biondi-Zoccal, Giusseppe G.
    Babic, Race
    Airoldi, Flavio
    Chieffo, Alaide
    Sangiorgi, Giusseppe G.
    Montorfano, Matteo
    Michev, Iassen
    Carlino, Mauro
    Colombo, Antonio
    CIRCULATION, 2006, 114 (18) : 689 - 689
  • [48] High-Dose Drug-Coated Balloon Versus Polymer-Based Drug-Eluting Stent for Femoropopliteal Artery Disease Treatment
    Soga, Yoshimitsu
    Takahara, Mitsuyoshi
    Iida, Osamu
    Tomoi, Yusuke
    Kawasaki, Daizo
    Fujihara, Masahiko
    Kozuki, Amane
    Tanaka, Akiko
    Yamauchi, Yasutaka
    Tobita, Kazuki
    Yamaoka, Terutoshi
    Ichihashi, Shigeo
    Ando, Kenji
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [49] Long-Term Clinical Outcomes of a Biodegradable Polymer-Based Biolimus-Eluting Stent
    Im, Eui
    Kim, Gwang-Sil
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (02) : 162 - 167
  • [50] A Comparative Prospective Analysis of Drug Eluting Stent with Biodegradable Polymer versus Drug Eluting Stent with Permanent Polymer in Bifurcation Lesions
    Kornowski, Ran
    Serra, Antonio
    Wijns, William C.
    Saito, Shigeru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B53 - B54