In vitro and in vivo characterisation of biodegradable polymer-based drug-eluting stent

被引:19
|
作者
Yazdani, Saami K. [1 ]
Vorpahl, Marc [1 ]
Nakano, Masataka [1 ]
Su, Shih-Horng [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
机构
[1] CVPath Inst Inc, Gaithersburg, MD 20878 USA
[2] Biosensors Int, Singapore, Singapore
关键词
drug-eluting stents; bio-erodible polymer; SEM; in vivo; in vitro; PLA; CORONARY-ARTERY; DURABLE POLYMER; IMPLANTATION; THROMBOSIS;
D O I
10.4244/EIJV7I7A131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The objective of this study was to investigate the structural integrity and early vascular response of a polylactic acid-coated (i.e., biodegradable polymer) coronary drug-eluting stent (DES) (BioMatrix (TM); Biosensors International, Singapore) to three currently marketed FDA/CE- mark approved non-erodible polymer-coated DES in a porcine model. Methods and results: BioMatrix (TM), XIENCE V (TM) (Abbott Vascular, Santa Clara, CA, USA), TAXUS (R) Liberte (TM) (Boston Scientific, Natick, MA, USA), and Cypher SELECT (TM) (Cordis, Johnson & Johnson, Miami, FL, USA) stems were implanted in pig coronaries for seven days. Polymer integrity was assessed by scanning electron microscopy (SEM) following tissue digestion. In vitro expansion of the BioMatrix (TM) was also performed. SEM analysis of in vivo stents demonstrated polymer defects on the abluminal surface of all DES including polymer cracking (BioMatrix (TM)), bridging (TAXUS Liberte (TM)), round-small defects (Cypher SELECT (TM)), and flaking (XIENCE V (TM)). Histologically, the myocardium revealed no evidence of acute myocardial infarction or microscopic scarring, moreover all intramyocardial vessels were found to be patent with no evidence of emboli. In vitro results demonstrated greater BioMatrix (TM) polymer cracking and lifting. Conclusions: These results illustrate the presence of polymer defects in all DES (TAXUS Liberte (TM), Cypher SELECT (TM), XIENCE V (TM), BioMatrix (TM)) implanted seven-days in pigs, with absence of myocardial damage in this small number of samples. Polymer coating irregularity was greater in BioMatrix (TM) stent expanded in vitro as compared to in vivo, suggesting simulated benchtop deployment induces greater damage to the biodegradable polymer coating than in vivo deployment in healthy porcine coronary arteries.
引用
收藏
页码:835 / 843
页数:9
相关论文
共 50 条
  • [31] An IVUS image report of coronary spasm induced by biodegradable-polymer drug-eluting stent
    Yang, Hongbo
    Dai, Yuxiang
    Qian, Juying
    Ge, Junbo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 187 : 299 - 301
  • [32] Stent Thrombosis in Patients With Coronary Artery Disease Treated With Biodegradable Polymer Drug-Eluting Stents
    Zhang, Jing
    INTERNATIONAL HEART JOURNAL, 2014, 55 (03) : 213 - 218
  • [33] A Review of the Ultrathin Orsiro Biodegradable Polymer Drug-eluting Stent in the Treatment of Coronary Artery Disease
    Wu, James J.
    Way, Joshua A. H.
    Brieger, David
    HEART INTERNATIONAL, 2019, 13 (02): : 17 - 24
  • [34] Biodegradable-Polymer Drug-Eluting Stent Platforms The Importance of Long-Term Outcomes
    Kutcher, Michael A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (10) : 1003 - 1005
  • [35] Paclitaxel/sirolimus combination coated drug-eluting stent: In vitro and in vivo drug release studies
    Ma, Xiaodong
    Oyamada, Shizu
    Gao, Fan
    Wu, Tim
    Robich, Michael P.
    Wu, Hao
    Wang, Xingwei
    Buchholz, Bryan
    McCarthy, Stephen
    Gu, Zhiyong
    Bianchi, Cesario F.
    Sellke, Frank W.
    Laham, Roger
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 807 - 811
  • [36] Biodegradable polymer drug-eluting stent vs. contemporary durable polymer drug-eluting stents in patients with diabetes: a meta-analysis of randomized controlled trials
    Bavishi, Chirag
    Chugh, Yashasvi
    Kimura, Takeshi
    Natsuaki, Masahiro
    Kaiser, Christoph
    Gordon, Paul
    Aronow, Herbert D.
    Abbott, Jinnette Dawn
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2020, 6 (01) : 81 - 88
  • [37] Preparation and in vitro release profiles of drug-eluting controlled biodegradable polymer coating stents
    Pan, Chang-Jiang
    Tang, Jia Ju
    Weng, Ya-Jun
    Wang, Jin
    Huang, Nan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 73 (02) : 199 - 206
  • [38] Drug-eluting stent technology: progress beyond the polymer
    Pilgrim, Thomas
    Windecker, Stephan
    EUROPEAN HEART JOURNAL, 2014, 35 (30) : 1991 - 1995
  • [39] Is a Drug-Eluting Stent the Default Treatment Strategy for Drug-Eluting Stent Restenosis?
    Colombo, Antonio
    Ruparelia, Neil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (01) : 34 - 36
  • [40] Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model
    Nakazawa, Gaku
    Shinke, Toshiro
    Ijichi, Takeshi
    Matsumoto, Daisuke
    Otake, Hiromasa
    Torii, Sho
    Hiranuma, Noritoshi
    Ohsue, Tsuyoshi
    Otsuka, Fumiyuki
    Shite, Junya
    Hirata, Ken-ichi
    Ikari, Yuji
    EUROINTERVENTION, 2014, 10 (06) : 717 - 723