Advances with tungsten coil atomizers:: Continuum source atomic absorption and emission spectrometry

被引:45
|
作者
Rust, JA
Nöbrega, JA
Calloway, CP
Jones, BT [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
[2] Univ Fed Sao Carlos, Dept Quim, Sao Carlos, SP, Brazil
[3] Winthrop Univ, Dept Chem Phys & Geol, Rock Hill, SC 29733 USA
关键词
Tungsten coil; electrothermal atomizer; continuum source; atomic absorption spectrometry; atomic emission spectrometry; Xe lamp; D-2; lamp;
D O I
10.1016/j.sab.2005.02.006
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Two new tungsten coil spectrometers are described: a continuum source tungsten coil atomic absorption spectrometer and a tungsten coil atomic emission spectrometer. Both devices use a 150 W tungsten coil extracted from a slide projector bulb. The power is provided by a computer-controlled, solid state, constant current 0-10 A supply. The heart of the optical system is a high-resolution spectrometer with a multi-channel detector. The continuum source system employs xenon or deuterium lamps, and is capable of multi-element analyses of complex samples like engine oil, urine, and polluted water. Spiked engine oil samples give mean percent recoveries of 98 +/- 9, 104 +/- 9, and 93 +/- 0.8 for Al, V, and Ni, respectively. Copper, Zn, and Cd are determined in urine samples; while Cd, Co, Yb, and Sr are determined in water samples. Detection limits for Cd, Zn, Cu, Yb, Sr, and Co are: 8, 40, 1, 4, 1, and 4 mu g l(-1). The technique of tungsten coil atomic emission spectrometry using a 150 W commercial projector bulb is reported for the first time. Calcium, Ba, and Sr are determined with detection limits of 0.01, 0.5, and 0.1 mu g l(-1). Relative standard deviations are lower than 10% in each case, and Sr is determined in two water standard reference materials. (c) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:589 / 598
页数:10
相关论文
共 50 条
  • [21] Evaluation of heating programs for electrothermal atomic absorption spectrometry using a tungsten coil
    Oliveira, PV
    Catanho, M
    Nóbrega, JA
    Luccas, PO
    QUIMICA NOVA, 2000, 23 (05): : 706 - 708
  • [22] Determination of cadmium and lead in mussels by tungsten coil electrothermal atomic absorption spectrometry
    Bruhn, CG
    San Francisco, NA
    Neira, JY
    Nóbrega, JA
    TALANTA, 1999, 50 (05) : 967 - 975
  • [23] Determination of ytterbium in animal faeces by tungsten coil electrothermal atomic absorption spectrometry
    Lima, EC
    Krug, FJ
    Nobrega, JA
    Nogueira, ARA
    TALANTA, 1998, 47 (03) : 613 - 623
  • [24] DETERMINATION OF MANGANESE IN SLUDGE, ALLOY, AND SOIL BY TUNGSTEN COIL ATOMIC EMISSION SPECTROMETRY
    Gonzalez, Mario Henrique
    Santos, Luana Novaes
    ANALYTICAL LETTERS, 2015, 48 (15) : 2434 - 2445
  • [25] Determination of Trace Elements in Cow Placenta by Tungsten Coil Atomic Emission Spectrometry
    Goncalves, Daniel A.
    Soncin, Ana C.
    Donati, George L.
    dos Santos, Mirian C.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2017, 178 (02) : 228 - 234
  • [26] Determination of Trace Elements in Cow Placenta by Tungsten Coil Atomic Emission Spectrometry
    Daniel A. Gonçalves
    Ana C. Soncin
    George L. Donati
    Mirian C. dos Santos
    Biological Trace Element Research, 2017, 178 : 228 - 234
  • [27] In situ digestion for the determination of Ca in beverages by tungsten coil atomic emission spectrometry
    Santos, Luana N.
    Gonzalez, Mario H.
    Moura, Monise F.
    Donati, George L.
    Nobrega, Joaquim A.
    TALANTA, 2012, 97 : 285 - 290
  • [28] MULTI-WAVELENGTH DETERMINATION OF COBALT BY TUNGSTEN COIL ATOMIC EMISSION SPECTROMETRY
    Donati, George L.
    Gonzales, Mario H.
    Nobrega, Joaquim A.
    Jones, Bradley T.
    ANALYTICAL LETTERS, 2010, 43 (10-11) : 1723 - 1733
  • [29] DETERMINATION OF BARIUM IN WATERS BY TUNGSTEN COIL ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    SILVA, MM
    SILVA, RB
    KRUG, FJ
    NOBREGA, JA
    BERNDT, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) : 861 - 865
  • [30] ELECTROTHERMAL ATOMIC-ABSORPTION AND ATOMIC-FLUORESCENCE SPECTROMETRY WITH A TUNGSTEN-COIL ATOMIZER
    MUZGIN, VN
    ATNASHEV, YB
    KOREPANOV, VE
    PUPYSHEV, AA
    TALANTA, 1987, 34 (01) : 197 - 200