Evaluation of heating programs for electrothermal atomic absorption spectrometry using a tungsten coil

被引:33
|
作者
Oliveira, PV
Catanho, M
Nóbrega, JA
Luccas, PO
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
来源
QUIMICA NOVA | 2000年 / 23卷 / 05期
关键词
atomic absorption spectrometry; tungsten coil; heating programs;
D O I
10.1590/S0100-40422000000500022
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A tungsten coil atomizer was used to investigate the effect of heating programs with constant or variable drying temperatures on the atomization of Al, Cd, Cr and Pb, The variation of the surface temperature in the tungsten coil furnace can occur during each heating step due to the design of the power supply, that may apply constant voltages during a programmed time. For volatile elements (Cd), losses in sensitivity were observed when the program with a variable temperature was used. On the other hand, these effects are negligible for less volatile elements (Al and Cr) and any tested program, in different acidic media, could be used without appreciable changes in sensitivities. The results allow the establishment of proper heating programs for elements with different thermochemical behavior in the tungsten coil atomizer.
引用
收藏
页码:706 / 708
页数:3
相关论文
共 50 条
  • [1] Determination of lead in blood by tungsten coil electrothermal atomic absorption spectrometry
    Krug, FJ
    Silva, MM
    Oliveira, PV
    Nobrega, JA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (12) : 1469 - 1474
  • [2] Determination of barium in waters by tungsten coil electrothermal atomic absorption spectrometry
    Silva, M.M., 1600, Royal Soc of Chemistry, Letchworth, United Kingdom (09):
  • [3] Determination of ytterbium in animal faeces by tungsten coil electrothermal atomic absorption spectrometry
    Lima, EC
    Krug, FJ
    Nobrega, JA
    Nogueira, ARA
    TALANTA, 1998, 47 (03) : 613 - 623
  • [4] Determination of cadmium and lead in mussels by tungsten coil electrothermal atomic absorption spectrometry
    Bruhn, CG
    San Francisco, NA
    Neira, JY
    Nóbrega, JA
    TALANTA, 1999, 50 (05) : 967 - 975
  • [5] DETERMINATION OF BARIUM IN WATERS BY TUNGSTEN COIL ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    SILVA, MM
    SILVA, RB
    KRUG, FJ
    NOBREGA, JA
    BERNDT, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) : 861 - 865
  • [6] Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extraction
    Wen, Xiaodong
    Wu, Peng
    Chen, Li
    Hou, Xiandeng
    ANALYTICA CHIMICA ACTA, 2009, 650 (01) : 33 - 38
  • [7] ELECTROTHERMAL ATOMIC-ABSORPTION AND ATOMIC-FLUORESCENCE SPECTROMETRY WITH A TUNGSTEN-COIL ATOMIZER
    MUZGIN, VN
    ATNASHEV, YB
    KOREPANOV, VE
    PUPYSHEV, AA
    TALANTA, 1987, 34 (01) : 197 - 200
  • [8] Separation and preconcentration by flow injection coupled to tungsten coil electrothermal atomic absorption spectrometry
    Silva, MM
    Krug, FJ
    Oliveira, PV
    Nobrega, JA
    Reis, BF
    Penteado, DAG
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) : 1925 - 1934
  • [9] Electrothermal atomic absorption spectrometry with tungsten coil. A critical re-view.
    Ribeiro, AS
    Arruda, MAZ
    Cadore, S
    QUIMICA NOVA, 2002, 25 (03): : 396 - 405
  • [10] Chemical modifiers in arsenic determination in biological materials by tungsten coil electrothermal atomic absorption spectrometry
    C. G. Bruhn
    V. N. Huerta
    J. Y. Neira
    Analytical and Bioanalytical Chemistry, 2004, 378 : 447 - 455