Advances with tungsten coil atomizers:: Continuum source atomic absorption and emission spectrometry

被引:45
|
作者
Rust, JA
Nöbrega, JA
Calloway, CP
Jones, BT [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
[2] Univ Fed Sao Carlos, Dept Quim, Sao Carlos, SP, Brazil
[3] Winthrop Univ, Dept Chem Phys & Geol, Rock Hill, SC 29733 USA
关键词
Tungsten coil; electrothermal atomizer; continuum source; atomic absorption spectrometry; atomic emission spectrometry; Xe lamp; D-2; lamp;
D O I
10.1016/j.sab.2005.02.006
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Two new tungsten coil spectrometers are described: a continuum source tungsten coil atomic absorption spectrometer and a tungsten coil atomic emission spectrometer. Both devices use a 150 W tungsten coil extracted from a slide projector bulb. The power is provided by a computer-controlled, solid state, constant current 0-10 A supply. The heart of the optical system is a high-resolution spectrometer with a multi-channel detector. The continuum source system employs xenon or deuterium lamps, and is capable of multi-element analyses of complex samples like engine oil, urine, and polluted water. Spiked engine oil samples give mean percent recoveries of 98 +/- 9, 104 +/- 9, and 93 +/- 0.8 for Al, V, and Ni, respectively. Copper, Zn, and Cd are determined in urine samples; while Cd, Co, Yb, and Sr are determined in water samples. Detection limits for Cd, Zn, Cu, Yb, Sr, and Co are: 8, 40, 1, 4, 1, and 4 mu g l(-1). The technique of tungsten coil atomic emission spectrometry using a 150 W commercial projector bulb is reported for the first time. Calcium, Ba, and Sr are determined with detection limits of 0.01, 0.5, and 0.1 mu g l(-1). Relative standard deviations are lower than 10% in each case, and Sr is determined in two water standard reference materials. (c) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:589 / 598
页数:10
相关论文
共 50 条
  • [41] CORRECTION FOR BACKGROUND ABSORPTION IN ATOMIC-ABSORPTION SPECTROMETRY WITH CARBON ATOMIZERS
    ROBINSON, JW
    HINDMAN, GD
    SLEVIN, PJ
    ANALYTICA CHIMICA ACTA, 1973, 66 (02) : 165 - 170
  • [42] Continuum source atomic absorption spectrometry and detector technology: A historical perspective
    Becker-Ross, H.
    Florek, S.
    Heitmann, U.
    Huang, M. D.
    Okruss, M.
    Radziuk, B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (09) : 1015 - 1030
  • [43] DETERMINATION OF CADMIUM IN URINE BY CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY
    FERNANDO, R
    JONES, BT
    ENNEVER, FK
    APPLIED SPECTROSCOPY, 1993, 47 (10) : 1696 - 1699
  • [45] Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extraction
    Wen, Xiaodong
    Wu, Peng
    Chen, Li
    Hou, Xiandeng
    ANALYTICA CHIMICA ACTA, 2009, 650 (01) : 33 - 38
  • [46] Separation and preconcentration by flow injection coupled to tungsten coil electrothermal atomic absorption spectrometry
    Silva, MM
    Krug, FJ
    Oliveira, PV
    Nobrega, JA
    Reis, BF
    Penteado, DAG
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) : 1925 - 1934
  • [47] DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY
    GINE, MF
    KRUG, FJ
    SASS, VA
    REIS, BF
    NOBREGA, JA
    BERNDT, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) : 243 - 245
  • [48] Permanent chemical modifier for the determination of selenium by tungsten coil atomic absorption spectrometry.
    Hou, XD
    Yang, Z
    Jones, BT
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U93 - U93
  • [49] Direct determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometry
    Goncalves, Daniel A.
    Gu, Jiyan
    dos Santos, Mirian C.
    Jones, Bradley T.
    Donati, George L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (06) : 1395 - 1399
  • [50] CHED 199-Tungsten coil atomic emission spectrometry with a fiber optic spectrometer
    Gray, Ashten M.
    Calloway, Clifton P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 235