A 5-year prospective multicenter study on 1-stage smooth-surface Branemark System implants with early loading in edentulous mandibles

被引:0
|
作者
Friberg, Bertil [1 ]
Raghoebar, Gerry M. [2 ]
Grunert, Ingrid [3 ]
Hobkirk, John A. [4 ]
Tepper, Gabor [5 ]
机构
[1] Clin Odontol, Branemark Clin, S-41390 Gothenburg, Sweden
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg & Maxillofacial Pr, NL-9700 AB Groningen, Netherlands
[3] Univ Innsbruck, Dept Prosthet Dent, A-6020 Innsbruck, Austria
[4] UCL, Div Restorat Dent Sci, UCL Eastman Dent Inst, London, England
[5] Sch Dent, Dept Oral Surg, Vienna, Austria
关键词
early loading; edentulous mandible; endosseous smooth-surface implants; osseointegration;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of the current prospective multicenter Study was to evaluate the 5-year implant success and peri-implant conditions of smooth-surface Branemark System implants when using a novel technique including a 1-stage surgical procedure with early loading in edentulous mandibles. Materials and Methods: The study protocol included 1-stage surgery as well as placement of the definitive prosthesis within 6 weeks after implant insertion (ie, early loading). Clinical evaluation, as well as evaluation of function and esthetics, was performed at each follow-up visit. Radiographs were obtained at connection of the prostheses and at the 1-, 3-, and 5-year check-ups. Results: A total of 40 patients with a mean age of 56 years (range, 30 to 70) were included in the study. In all, 170 implants were placed in between the mental foramina, of which 120 implants in 30 patients were associated with overdenture treatment and 50 implants in 10 patients with fixed complete dentures. Twelve implants failed in 6 patients. The cumulative implant survival rate was 92.9% after both 1 and 5 years of follow-up. Another 3 implants were recorded as mobile but still in function when individually checked at the 5-year visit, which resulted in a cumulative success rate of 91.0%. Mean bone remodeling over the study period was less than 0.1 mm/y after the first year of loading, resulting in a mean marginal bone level of 0.66 mm (SD 0.73, n = 138) apical to the? implant collar reference point after 5 years. Conclusions. One-stage, early loaded smooth-surface Branemark System implants functioned well for the majority of patients with edentulous mandibles. Stable peri-implant conditions were observed. Bone remodeling resulted in a mean bone level above the first implant thread after 5 years. The somewhat lower success rate of 91.0% compared to a 2-stage procedure may be related to generous inclusion criteria and to a learning curve involving a novel treatment procedure.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [21] Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study
    Gherlone, Enrico F.
    Sannino, Gianpaolo
    Rapanelli, Andrea
    Crespi, Roberto
    Gastaldi, Giorgio
    Cappare, Paolo
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [22] Early and immediate loading of titanium implants with fluoride-modified surfaces: results of 5-year prospective study
    Mertens, Christian
    Steveling, Helmut G.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (12) : 1354 - 1360
  • [23] Rehabilitation of Edentulous Mandibles by Means of Osseointegrated Implants: A 5-Year Follow-Up Study on One or Two-Stage Surgery, Number of Implants, Implant Surfaces, and Age at Surgery
    Friberg, Bertil
    Jemt, Torsten
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) : 413 - 424
  • [24] Immediate occlusal loading and tilted implants for the rehabilitation of the atrophic edentulous maxilla: 1-year interim results of a multicenter prospective study
    Testori, Tiziano
    Del Fabbro, Massimo
    Capelli, Matteo
    Zuffetti, Francesco
    Francetti, Luca
    Weinstein, Roberto L.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 227 - 232
  • [25] Immediate functional loading of single implants: A 1-year interim report of a 5-year prospective multicentre study
    Luongo, Giuseppe
    Lenzi, Carolina
    Raes, Filiep
    Eccellente, Tammaro
    Ortolani, Michele
    Mangano, Carlo
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (02) : 187 - 199
  • [26] Implant-supported welded titanium frameworks in the edentulous maxilla: A 5-year prospective multicenter study
    Jemt, T
    Bergendal, B
    Arvidson, K
    Bergengal, T
    Karlsson, U
    Linden, B
    Rundcrantz, T
    Wendelhag, I
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (06) : 544 - 548
  • [27] Early loading of 6-mm-short implants with a moderately rough surface supporting single crowns - a prospective 5-year cohort study
    Rossi, Fabio
    Lang, Niklaus P.
    Ricci, Emanuele
    Ferraioli, Lorenzo
    Marchetti, Claudio
    Botticelli, Daniele
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (04) : 471 - 477
  • [28] Immediate loading of dental implants in edentulous mandibles using Locator attachments or Dolder bars: A 9-year prospective randomized clinical study
    Kostunov, Jana
    Menzel, Regina
    Bermejo, Justo Lorenzo
    Rammelsberg, Peter
    Giannakopoulos, Nikolaos Nikitas
    Kappel, Stefanie
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, 50 (11) : 1530 - 1538
  • [29] Immediate Placement of Tapered Effect (TE) Implants: 5-Year Results of a Prospective, Multicenter Study
    Wilson, Thomas G., Jr.
    Roccuzzo, Mario
    Ucer, Cemal
    Beagle, Jay R.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 261 - 269
  • [30] Immediate/early function of Branemark System® TiUnite™ implants in fresh extraction sockets in maxillae and posterior mandibles:: An 18-month prospective clinical study
    Bogaerde, LV
    Rangert, B
    Wendelhag, I
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S121 - S130