Early loading of 6-mm-short implants with a moderately rough surface supporting single crowns - a prospective 5-year cohort study

被引:67
|
作者
Rossi, Fabio [1 ]
Lang, Niklaus P. [2 ,3 ]
Ricci, Emanuele [4 ]
Ferraioli, Lorenzo [1 ]
Marchetti, Claudio [4 ]
Botticelli, Daniele [5 ,6 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotorial Sci, Unit Scholar, Bologna, Italy
[2] Univ Bern, Bern, Switzerland
[3] Univ Zurich, Zurich, Switzerland
[4] Univ Bologna, Dept Biomed & Neuromotorial Sci, Bologna, Italy
[5] UNESP Sao Paulo State Univ, Fac Dent Aracatuba SP, Aracatuba, Brazil
[6] Ariminum Odontol, ARDEC, Rimini, Italy
关键词
dental implants; early loading; implant length; prospective cohort; short implants; SLActive surface; SHORT DENTAL IMPLANTS; FIXED PARTIAL DENTURES; POSTERIOR REGION; COMPLICATION RATES; SURVIVAL; REHABILITATION; LENGTH; TRIAL; MM;
D O I
10.1111/clr.12409
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo evaluate prospectively the clinical and radiographic outcomes after 5years of early loading of 6-mm implants with a moderately rough (SLActive((R))) surface supporting single crowns in the posterior regions. Material and methodsThirty-five consecutive patients received 40 SLActive((R)) (Straumann) 6-mm implants with a diameter of 4.1mm (n=19) or 4.8mm (n=21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35Ncm after 6weeks of healing, and single porcelain fuse to metal crowns was cemented within 1week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5years after loading. The clinical crown/implant ratio was calculated as well. ResultsTwo of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5-year follow-up period. A mean marginal bone loss of 0.70.6mm was found after 5years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5years of loading. ConclusionSix millimeter implants with a SLActive((R)) moderately rough surface supporting single crowns in the posterior region and loaded after 6-7weeks maintained full function for at least 5year with low marginal bone resorption.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 50 条
  • [1] Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study
    Rossi, Fabio
    Ricci, Emanuele
    Marchetti, Claudio
    Lang, Niklaus P.
    Botticelli, Daniele
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (09) : 937 - 943
  • [2] A prospective, multicentre study of 6-mm short implants in posterior alveolar bone supporting splinted crowns: A 5-year follow-up study
    Sui, Huiping
    Tang, Zhihui
    Zhang, Xiao
    Wei, Diyuan
    Meng, Huanxin
    Han, Jie
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2022, 49 (06) : 537 - 546
  • [3] Long-term follow-up of single crowns supported by short, moderately rough implants-A prospective 10-year cohort study
    Rossi, Fabio
    Lang, Niklaus P.
    Ricci, Emanuele
    Ferraioli, Lorenzo
    Baldi, Niccolo
    Botticelli, Daniele
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1212 - 1219
  • [4] Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study
    Lombardo, Giorgio
    Signoriello, Annarita
    Marincola, Mauro
    Liboni, Pietro
    Bonfante, Estevam A.
    Nocini, Pier F.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (06) : 904 - 919
  • [5] A 5-year prospective clinical trial on short implants (6 mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading
    Mustafa Ayna
    Bastian Wessing
    Ralf Gutwald
    Andreas Neff
    Thomas Ziebart
    Yahya Açil
    Jörg Wiltfang
    Aydin Gülses
    [J]. Odontology, 2019, 107 : 244 - 253
  • [6] Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study
    Bregagnol, Raphaela Brambilla
    Coltro, Maria Paula de Lima
    Villarinho, Eduardo Aydos
    Triches, Diego Fernandes
    Alonso, Fernando Rizzo
    Mezzomo, Luis Andre Mendonca
    de Macedo, Bianca Brandelli
    Teixeira, Eduardo Rolim
    Vigo, Alvaro
    Shinkai, Rosemary Sadami Arai
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (01) : 158 - 169
  • [7] Short (5 and 7mm long) porous implants in the posterior atrophic maxilla: a 5-year report of a prospective single-cohort study
    Perelli, Michele
    Abundo, Roberto
    Corrente, Giuseppe
    Saccone, Carlo
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2012, 5 (03) : 265 - 272
  • [8] A 5-year prospective clinical trial on short implants (6mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading
    Ayna, Mustafa
    Wessing, Bastian
    Gutwald, Ralf
    Neff, Andreas
    Ziebart, Thomas
    Acil, Yahya
    Wiltfang, Joerg
    Guelses, Aydin
    [J]. ODONTOLOGY, 2019, 107 (02) : 244 - 253
  • [9] Zirconia implants restored with single crowns or fixed dental prostheses: 5-year results of a prospective cohort investigation
    Balmer, Marc
    Spies, Benedikt C.
    Kohal, Ralf-Joachim
    Haemmerle, Christoph Hans-Franz
    Vach, Kirstin
    Jung, Ronald E.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (05) : 452 - 462
  • [10] Immediate Restoration of Single Tapered Implants with Nonoccluding Provisional Crowns: A 5-Year Clinical Prospective Study
    Lang, Lisa A.
    Turkyilmaz, Ilser
    Edgin, Wendell A.
    Verrett, Ronald
    Garcia, Lily T.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (02) : 248 - 258