Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses

被引:9
|
作者
Jousi, Milla [1 ,2 ,3 ,5 ]
Saikko, Simo [4 ]
Nurmi, Jouni [1 ,2 ,3 ]
机构
[1] Helsinki Univ Hosp, Emergency Med & Serv, Helsinki, Finland
[2] Univ Helsinki, Dept Emergency Med, Helsinki, Finland
[3] HYKS Akuutti, PL 340, Hus Helsinki 00029, Finland
[4] Saimaa Univ Appl Sci, Skinnarilankatu 36, Lappeenranta 53850, Finland
[5] FinnHEMS Res & Dev Unit, Lentajantie 3, Vantaa 01530, Finland
关键词
Point-of-care; Blood gas analysis; Intraosseous access; I-STAT; BONE-MARROW ASPIRATE; ACID-BASE STATUS; ANESTHETIZED PIG; CARDIOPULMONARY-RESUSCITATION; VENOUS SITES; RELIABILITY; GUIDELINES; VALUES; SHOCK;
D O I
10.1186/s13049-017-0435-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Methods: Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT (R) POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Results: Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. Discussion: POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO and arterial results among unstable patients. Conclusions: IO blood samples are suitable for analysis with the i-STAT (R) point-of-care device in emergency care. The aspirate used to confirm the correct placement of the IO needle can also be used for analysis. The results must be interpreted within a clinical context while taking the magnitude and direction of bias into account.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Evaluation of agreement between a noninvasive method for real-time measurement of critical blood values with a standard point-of-care device
    Ettrich, Rudi H.
    Caballero, Joshua
    Sakharkar, Prashant
    Ahmed, Sultan
    Hurlston, Traci
    Parmar, Jayesh
    Deb, Subrata
    PLOS ONE, 2024, 19 (06):
  • [42] A POINT-OF-CARE ASSAY TO DETECT ANTIMALARIAL DRUGS FROM FINGER STICK BLOOD SAMPLES
    Coonahan, Erin
    Fairhurst, Rick
    De Vos, Maarten
    Tarning, Joel
    Wellems, Tom
    Long, Carole
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 97 (05): : 296 - 297
  • [43] Evaluation of a new handheld point-of-care blood gas analyser using 100 equine blood samples
    Bardell, David
    West, Eleanor
    Senior, J. Mark
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (01) : 77 - 85
  • [44] INTENSIVE CARE POINT OF CARE TESTING FOR ARTERIAL BLOOD GAS ANALYSES: A PROSPECTIVE OBSERVATIONAL STUDY
    Watts, Stacey
    AUSTRALIAN CRITICAL CARE, 2020, 33 : S22 - S22
  • [45] Analysis of thromboelastography, PT, APTT and fibrinogen in intraosseous and venous samples-an experimental study
    Strandberg, Gunnar
    Lipcsey, Miklos
    Eriksson, Mats
    Lubenow, Norbert
    Larsson, Anders
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2016, 24
  • [46] A comparative study between point-of-care hemoglobin (capillary samples) and laboratory hemoglobin result (venous samples)
    Yu, Chun Hiu
    Lam, Shing Kit Tommy
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2024, 31 (05) : 261 - 266
  • [47] Correction factor to improve agreement between point-of-care and laboratory International Normalized Ratio values
    Johnson, Stacy A.
    Vazquez, Sara R.
    Fleming, Ryan
    Lanspa, Michael J.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2017, 74 (01) : E24 - E31
  • [48] Point-of-care magnetic platforms for molecular analyses of pathogens
    Liong, Monty
    Weissleder, Ralph
    Lee, Hakho
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [49] Using Smell To Triage Samples in Point-of-Care Assays
    Mohapatra, Hemakesh
    Phillips, Scott T.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (44) : 11145 - 11148
  • [50] Point-of-Care Analysis of Blood Ammonia with a Gas-Phase Sensor
    Veltman, Thomas R.
    Tsai, Chun J.
    Gomez-Ospina, Natalia
    Kanan, Matthew W.
    Chu, Gilbert
    ACS SENSORS, 2020, 5 (08) : 2415 - 2421