Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses

被引:9
|
作者
Jousi, Milla [1 ,2 ,3 ,5 ]
Saikko, Simo [4 ]
Nurmi, Jouni [1 ,2 ,3 ]
机构
[1] Helsinki Univ Hosp, Emergency Med & Serv, Helsinki, Finland
[2] Univ Helsinki, Dept Emergency Med, Helsinki, Finland
[3] HYKS Akuutti, PL 340, Hus Helsinki 00029, Finland
[4] Saimaa Univ Appl Sci, Skinnarilankatu 36, Lappeenranta 53850, Finland
[5] FinnHEMS Res & Dev Unit, Lentajantie 3, Vantaa 01530, Finland
关键词
Point-of-care; Blood gas analysis; Intraosseous access; I-STAT; BONE-MARROW ASPIRATE; ACID-BASE STATUS; ANESTHETIZED PIG; CARDIOPULMONARY-RESUSCITATION; VENOUS SITES; RELIABILITY; GUIDELINES; VALUES; SHOCK;
D O I
10.1186/s13049-017-0435-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Methods: Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT (R) POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Results: Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. Discussion: POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO and arterial results among unstable patients. Conclusions: IO blood samples are suitable for analysis with the i-STAT (R) point-of-care device in emergency care. The aspirate used to confirm the correct placement of the IO needle can also be used for analysis. The results must be interpreted within a clinical context while taking the magnitude and direction of bias into account.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Intraosseous blood gases during hypothermia:: Correlation with arterial, mixed venous, and sagittal sinus blood
    Voelckel, WG
    Lindner, KH
    Wenzel, V
    Krismer, AC
    Hund, W
    Müller, G
    Oroszy, S
    Kornberger, E
    Lurie, KG
    Mair, P
    CRITICAL CARE MEDICINE, 2000, 28 (08) : 2915 - 2920
  • [22] Analysis of intraosseous samples in endotoxemic shock - an experimental study in the anaesthetised pig
    Strandberg, G.
    Larsson, A.
    Lipcsey, M.
    Berglund, L.
    Eriksson, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (03) : 337 - 344
  • [23] Relationship Between Arterial and Intraosseous Pressure in African Grey Parrots (Psittacus erithacus)
    Peng, Yun-Wen
    Chi, Chau-Hwa
    Yu, Pin-Huan
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2021, 35 (04) : 402 - 411
  • [24] High Agreement Between Benchtop and Point-of-Care Dipcard Tests for Ethyl Glucuronide
    Leickly, Emily
    Skalisky, Jordan
    McPherson, Sterling
    Orr, Michael F.
    McDonell, Michael G.
    THERAPEUTIC DRUG MONITORING, 2017, 39 (04) : 461 - 462
  • [25] ABO and D typing and alloantibody screening in marrow samples: relevance to intraosseous blood transfusion
    Backman, Sari
    Angerman-Haasmaa, Susanne
    Jousi, Milla
    Siitonen, Sanna
    Salmela, Katja
    TRANSFUSION, 2018, 58 (06) : 1372 - 1376
  • [26] Point-of-Care Testing Devices for Heart Failure Analyzing Blood and Saliva Samples
    Tripoliti, Evanthia E.
    Ioannidou, Penelope
    Toumpaniaris, Petros
    Rammos, Aidonis
    Pacitto, Dominique
    Lourme, Jean-Christophe
    Goletsis, Yorgos
    Naka, Katerina K.
    Errachid, Abdelhamid
    Fotiadis, Dimitrios, I
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2020, 13 : 17 - 31
  • [27] Assay validity of point-of-care platelet function tests in thrombocytopenic blood samples
    Lacom, Conrad
    Tolios, Alexander
    Loeffler, Markus W.
    Eichelberger, Beate
    Quehenberger, Peter
    Schaden, Eva
    Wiegele, Marion
    BIOCHEMIA MEDICA, 2022, 32 (02)
  • [28] Effects of time delay and blood storage methods on analysis of canine venous blood samples with an Element point-of-care analyzer
    Rincon, Angie A. A.
    Wurlod, Virginie A. A.
    Liu, Chin-Chi
    Smith, M. Ryan
    VETERINARY CLINICAL PATHOLOGY, 2023, 52 (01) : 22 - 29
  • [29] A lab-on-a-CD system for point-of-care testing of whole blood samples
    Jun Yang
    医用生物力学, 2013, 28(S1) (S1) : 79 - 79
  • [30] Analysis of thromboelastography, PT, APTT and fibrinogen in intraosseous and venous samples—an experimental study
    Gunnar Strandberg
    Miklós Lipcsey
    Mats Eriksson
    Norbert Lubenow
    Anders Larsson
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 24