It is difficult to directly co-register the 3D FMT (Fluorescence Molecular Tomography) image of a small tumor in a mouse whose maximal diameter is only a few turn with a larger CT image of the entire animal that spans about ten cm. This paper proposes a new method to register 2D flat and 3D CT image first to facilitate the registration between small 3D FMT images and large CT images. A novel algorithm based on SMC (Sequential Monte Carlo) incorporated with least square operation for the registration between the 2D flat and 3D CT images is introduced and validated with simulated images and real images of mice. The visualization of the preliminary alignment of the 3D FMT and CT image through 2D registration shows promising results.
引用
收藏
页码:48 / +
页数:2
相关论文
共 50 条
  • [21] Monte Carlo Localization using 3D Texture Maps
    Fu, Yu
    Tully, Stephen
    Kantor, George
    Choset, Howie
    2011 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2011, : 482 - 487
  • [22] Comparison of simultaneous and sequential two-view registration for 3D/2D registration of vascular images
    Pathak, C
    Van Horn, M
    Weeks, S
    Bullitt, E
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 239 - 246
  • [23] FLUKA Monte Carlo code for patient specific 3D dosimetry based on SPECT/PET-CT images
    Botta, F.
    Mairani, A.
    Parodi, K.
    Di Dia, A.
    Cremonesi, M.
    Ferrari, M.
    Pedroli, G.
    Paganelli, G.
    Battistoni, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S245 - S245
  • [24] 3D affine registration using Teaching-Learning Based Optimization
    Jani, Ashish
    Savsani, Vimal
    Pandya, Abhijit
    3D RESEARCH, 2013, 4 (03) : 1 - 6
  • [25] Fast 3D reconstruction of satellite images via the Global Affine Model
    Chen B.
    Wang P.
    Dong Q.
    National Remote Sensing Bulletin, 2024, 28 (06) : 1576 - 1587
  • [26] Registration-based Automatic 3D Segmentation of Cardiac CT Images
    LI Li-hua
    YANG Rong-qian
    HUANG Yue-shan
    WU Xiao-ming
    ChineseJournalofBiomedicalEngineering, 2016, 25 (03) : 93 - 99
  • [27] Registration of bone ultrasound images to CT based 3D bone models
    Goncalves, Paulo J. S.
    Torres, Pedro M. B.
    TECHNOLOGY AND MEDICAL SCIENCES - TMSI 2010, 2011, : 245 - 250
  • [28] Automatic prostate localization using elastic registration of planning CT and daily 3D ultrasound images
    Wu, Jianzhou
    Dandekar, Omkar
    Walimbe, Vivek
    D'Souza, Warren
    Shekhar, Raj
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [29] Monte Carlo methods in sequential and parallel computing of 2D and 3D Ising model
    Diaconu, M
    Puscasu, R
    Stancu, A
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2003, 5 (04): : 971 - 976
  • [30] Recovering 3D tumor locations from 2D bioluminescence images and registration with CT images
    Huang, Xiaolei
    Metaxas, Dimitris N.
    Menon, Lata G.
    Mayer-Kuckuk, Philipp
    Bertino, Joseph R.
    Banerjee, Debabrata
    MULTIMODAL BIOMEDICAL IMAGING, 2006, 6081