Modulation frequency discrimination with single and multiple channels in cochlear implant users

被引:5
|
作者
Galvin, John J., III [1 ,2 ,3 ,4 ]
Oba, Sandy [1 ,2 ]
Baskent, Deniz [3 ,4 ]
Fu, Qian-Jie [1 ,2 ]
机构
[1] House Res Inst, Div Commun & Auditory Neurosci, Los Angeles, CA USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA 90095 USA
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Otorhinolaryngol Head & Neck Surg, Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Grad Sch Med Sci, Res Sch Behav & Cognit Neurosci, Groningen, Netherlands
关键词
TEMPORAL PERIODICITY CUES; CARRIER PULSE-RATE; AMPLITUDE-MODULATION; SPEECH RECOGNITION; INTENSITY DISCRIMINATION; VOWEL IDENTIFICATION; PROSODIC PERCEPTION; ELECTRICAL HEARING; STIMULATION RATE; LISTENERS;
D O I
10.1016/j.heares.2015.02.007
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Temporal envelope cues convey important speech information for cochlear implant (CI) users. Many studies have explored CI users' single-channel temporal envelope processing. However, in clinical Cl speech processors, temporal envelope information is processed by multiple channels. Previous studies have shown that amplitude modulation frequency discrimination (AMFD) thresholds are better when temporal envelopes are delivered to multiple rather than single channels. In clinical fitting, current levels on single channels must often be reduced to accommodate multi-channel loudness summation. As such, it is unclear whether the multi-channel advantage in AMFD observed in previous studies was due to coherent envelope information distributed across the cochlea or to greater loudness associated with multi-channel stimulation. In this study, single- and multi-channel AMFD thresholds were measured in CI users. Multi-channel component electrodes were either widely or narrowly spaced to vary the degree of overlap between neural populations. The reference amplitude modulation (AM) frequency was 100 Hz, and coherent modulation was applied to all channels. In Experiment 1, single- and multi-channel AMFD thresholds were measured at similar loudness. In this case, current levels on component channels were higher for single-than for multi-channel AM stimuli, and the modulation depth was approximately 100% of the perceptual dynamic range (i.e., between threshold and maximum acceptable loudness). Results showed no significant difference in AMFD thresholds between similarly loud single- and multi-channel modulated stimuli. In Experiment 2, single- and multi-channel AMFD thresholds were compared at substantially different loudness. In this case, current levels on component channels were the same for single- and multi-channel stimuli ("summation-adjusted" current levels) and the same range of modulation (in dB) was applied to the component channels for both single- and multi-channel testing. With the summation-adjusted current levels, loudness was lower with single than with multiple channels and the AM depth resulted in substantial stimulation below single-channel audibility, thereby reducing the perceptual range of AM. Results showed that AMFD thresholds were significantly better with multiple channels than with any of the single component channels. There was no significant effect of the distribution of electrodes on multi-channel AMFD thresholds. The results suggest that increased loudness due to multi-channel summation may contribute to the multi-channel advantage in AMFD, and that overall loudness may matter more than the distribution of envelope information in the cochlea. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 18
页数:12
相关论文
共 50 条
  • [1] Discrimination of Stochastic Frequency Modulation by Cochlear Implant Users
    Sheft, Stanley
    Cheng, Min-Yu
    Shafiro, Valeriy
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2015, 26 (06) : 572 - 581
  • [2] Modulation Depth Discrimination by Cochlear Implant Users
    Monaghan, Jessica J. M.
    Carlyon, Robert P.
    Deeks, John M.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2022, 23 (02): : 285 - 299
  • [3] Modulation Depth Discrimination by Cochlear Implant Users
    Jessica J. M. Monaghan
    Robert P. Carlyon
    John M. Deeks
    Journal of the Association for Research in Otolaryngology, 2022, 23 : 285 - 299
  • [4] Envelope Interactions in Multi-Channel Amplitude Modulation Frequency Discrimination by Cochlear Implant Users
    Galvin, John J., III
    Oba, Sandra I.
    Baskent, Deniz
    Chatterjee, Monita
    Fu, Qian-Jie
    PLOS ONE, 2015, 10 (10):
  • [5] Modulation Frequency Discrimination with Modulated and Unmodulated Interference in Normal Hearing and in Cochlear-Implant Users
    Heather A. Kreft
    David A. Nelson
    Andrew J. Oxenham
    Journal of the Association for Research in Otolaryngology, 2013, 14 : 591 - 601
  • [6] Modulation Frequency Discrimination with Modulated and Unmodulated Interference in Normal Hearing and in Cochlear-Implant Users
    Kreft, Heather A.
    Nelson, David A.
    Oxenham, Andrew J.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2013, 14 (04): : 591 - 601
  • [7] Free field frequency discrimination abilities of cochlear implant users
    Pretorius, L. L.
    Hanekom, J. J.
    HEARING RESEARCH, 2008, 244 (1-2) : 77 - 84
  • [8] Frequency modulation detection with simultaneous amplitude modulation by cochlear implant users
    Luo, Xin
    Fu, Qian-Jie
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (02): : 1046 - 1054
  • [9] Electrophysiological and psychophysical measures of amplitude modulation discrimination in cochlear implant users
    Department of Clinical Neurosciences, University of Cambridge, United Kingdom
    不详
    不详
    Proc. Int. Congr. Acoust., (2220-2226):
  • [10] Electroacoustic verification of frequency modulation systems in cochlear implant users
    Destro Fidencio, Vanessa Luisa
    de Souza Jacob, Regina Tangerino
    Tanamati, Liege Franzini
    Bucuvic, Erika Cristina
    Mortari Moret, Adriane Lima
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2019, 85 (02) : 162 - 169