Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT

被引:17
|
作者
Greco, Adelaide [1 ,3 ]
Petretta, Maria Piera [2 ]
Larobina, Michele [4 ]
Gargiulo, Sara [1 ]
Panico, Mariarosaria [4 ]
Nekolla, Stephan G. [5 ]
Esposito, Giovanni [2 ]
Petretta, Mario [2 ]
Brunetti, Arturo [1 ,3 ,4 ]
Cuocolo, Alberto [1 ,4 ]
机构
[1] Univ Naples Federico II, Dept Biomorphol & Funct Sci, I-80131 Naples, Italy
[2] Univ Naples Federico II, Dept Internal Med Cardiovasc & Immunol Sci, I-80131 Naples, Italy
[3] CEINGE Scarl, Naples, Italy
[4] CNR, Inst Biostruct & Bioimages, Naples, Italy
[5] Tech Univ Munich, Nukl Med Klin & Poliklin, Munich, Germany
关键词
Infarct size; measurement; mouse; PET/CT; F-18-FDG; EMISSION COMPUTED-TOMOGRAPHY; REPERFUSION; ISCHEMIA; RATS;
D O I
10.1007/s12350-012-9538-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study assessed the reproducibility and accuracy of 2-deoxy-2[F-18]fluoro-d-glucose (F-18-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. Mice were studied by F-18-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% +/- A 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution F-18-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [31] Characterization of Rock Samples by A High-Resolution Multi-Technique Non-Invasive Approach
    Fais, Silvana
    Cuccuru, Francesco
    Casula, Giuseppe
    Bianchi, Maria Giovanna
    Ligas, Paola
    MINERALS, 2019, 9 (11)
  • [32] Non-invasive, high-resolution optical coherence tomography for the early detection of dental caries
    Messeih, K
    Waite, W
    Jung, WG
    Schoop, U
    Chen, Z
    Wilder-Smith, P
    LASERS IN SURGERY AND MEDICINE, 2004, : 69 - 69
  • [33] High-resolution, non-invasive animal tracking and reconstruction of local environment in aquatic ecosystems
    Francisco, Fritz A.
    Nuehrenberg, Paul
    Jordan, Alex
    MOVEMENT ECOLOGY, 2020, 8 (01)
  • [34] High-resolution non-invasive X-ray diffraction analysis of artists' paints
    Hiley, Craig, I
    Hansford, Graeme
    Eastaugh, Nicholas
    JOURNAL OF CULTURAL HERITAGE, 2022, 53 : 1 - 13
  • [35] Non-invasive measurement of duodenal epithelial pH in mice
    Hirokawa, M
    Furukawa, O
    Chu, SY
    Montrose, MH
    Kaunitz, JD
    GASTROENTEROLOGY, 2002, 122 (04) : A112 - A112
  • [36] Non-invasive Pulse Wave Velocity Measurement in Mice
    Zakaria, Hasballah
    Hasimun, Patonah
    2017 INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM), 2017, : 95 - 98
  • [37] WAVELENGTH ACCURACY AND REPRODUCIBILITY OF A HIGH-RESOLUTION COMPUTER-CONTROLLED MONOCHROMATOR
    TAYLOR, P
    JANSSENS, E
    DAMS, R
    HOSTE, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (07) : 867 - 878
  • [39] Accuracy of non-invasive hemoglobin level measurement in the emergency department
    Aseri, Zohair Ahmed Ali Al
    Aldawood, Badr Abdulrahman
    Altamimi, Adel Abdullah
    Mosleh, Haytam Issa
    Qaw, Amnah Samir
    Albatran, Hawra Ibraheem
    AlMasri, Maram Mohammed
    AlRihan, Tasneem Muhammed
    AlAithan, Fatimah Bassem
    AlAssaf, Laura Suliaman
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2023, 64 : 200 - 203
  • [40] High-resolution PET/CT: Impact on SUVs determination
    Hofmann, M.
    Weitzel, T.
    Weidner, S.
    Corminboeuf, F.
    Krause, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S201 - S201