Non-invasive Pulse Wave Velocity Measurement in Mice

被引:0
|
作者
Zakaria, Hasballah [1 ]
Hasimun, Patonah [2 ]
机构
[1] Inst Technol Bandung, Dept Biomed Engn, Bandung, Indonesia
[2] Bandung Sch Pharm, Res Grp, Dept Pharmacol, Bandung, Indonesia
关键词
Atherosclerosis; electrocardiogram; measurement; photoplethysmogram; PWV; stiffness; E-KNOCKOUT MICE; ATHEROSCLEROSIS; CHOLESTEROL; RATS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Atherosclerosis, hardening of the arteries, causes heart attacks and strokes that are recorded as the world's number one killer disease. Nowadays, research on atherosclerosis is still limited because the modeling of atherosclerotic animals is difficult to do. Pulse wave velocity (PWV) is used clinically as a measure of arterial stiffness. PWV measurements in animals can be done invasively and non-invasively. PWV values have a strong correlation with cardiovascular conditions. This study aimed to create a PWV measuring instrument in mice to estimate the occurrence of atherosclerosis. The device developed will be highly beneficial in enhancing the research and development of anti-atherosclerotic drugs. PWV measurement was performed non-invasively by using electrocardiogram (ECG) and photoplethysmogram (PPG) sensors. The ECG electrode was placed on the left and right front legs and right rear leg of the test animal. While the PPG sensor placed on the rat tail. PWV is the traveling speed along the arterial segment from the heart position point to the PPG sensor position at the base of the tail. By comparing the EKG and PPG waveforms the amount of travel time (Pulse transit time, PTT) can be determined. The measurement results were obtained in less than a minute. The average PWV measurement results with the proposed method in normal mice aged one to three months was 480 cm/s, within the range of the results obtained by existing standard methods.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 50 条
  • [1] Non-invasive assessment of pulse wave velocity in mice by means of ultrasound images
    Di Lascio, Nicole
    Stea, Francesco
    Kusmic, Claudia
    Sicari, Rosa
    Faita, Francesco
    [J]. ATHEROSCLEROSIS, 2014, 237 (01) : 31 - 37
  • [2] Limitations and pitfalls of non-invasive measurement of arterial pressure wave reflections and pulse wave velocity
    Segers P.
    Kips J.
    Trachet B.
    Swillens A.
    Vermeersch S.
    Mahieu D.
    Rietzschel E.
    De Buyzere M.
    Van Bortel L.
    [J]. Artery Research, 2009, 3 (2) : 79 - 88
  • [3] NON-INVASIVE MEASUREMENT OF AORTIC PULSE WAVE VELOCITY: A COMPARATIVE EVALUATION OF EIGHT DEVICES
    Grillo, A.
    Moretti, F.
    Rovina, M.
    Baldi, C.
    Salvi, L.
    Gao, L.
    Scalise, F.
    Sorropago, G.
    Faini, A.
    Millasseau, S.
    Salvi, P.
    Carretta, R.
    Parati, G.
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E199 - E199
  • [4] Repeatability of non-invasive measurement of intracerebral pulse wave velocity using transcranial Doppler
    Gladdish, S
    Manawadu, D
    Banya, W
    Cameron, J
    Bulpitt, CJ
    Rajkumar, C
    [J]. CLINICAL SCIENCE, 2005, 108 (05) : 433 - 439
  • [5] The aortic Pulse Wave Velocity as an independent Predictor of cardiovascular Events - A Comparison of invasive and non-invasive Measurement
    Danninger, Kathrin
    Hametner, Bernhard
    Wassertheurer, Siegfried
    Mayer, Christopher Clemens
    Binder, Ronald
    Weber, Thomas
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 : 299 - 300
  • [6] NON-INVASIVE MEASUREMENT OF HEART-FEMORAL PULSE WAVE VELOCITY: CORRELATES, REPRODUCIBILITY AND COMPARISON WITH CAROTID-FEMORAL PULSE WAVE VELOCITY
    Magistri, C.
    Raso, F. U. S. Mattace
    Battista, F.
    Anastasio, F.
    Pucci, G.
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E224 - E224
  • [7] ARTERIAL PULSE WAVE VELOCITY AS A NON-INVASIVE INDEX OF MYOCARDIAL CONTRACTILITY
    ARONSON, AL
    MILLER, S
    GULOTTA, SJ
    [J]. CIRCULATION, 1972, 46 (04) : 126 - &
  • [8] Comparison of non-invasive measurement of caroid - Femoral pulse wave velocity and invasive maesurement of aortic pulse wave velocity and their accuracy in identification of patients with coronary artery disease.
    Podolec, Piotr
    Kopec, Grzegorz
    Podolec, Jakub
    Wilkolek, Piotr
    Krochin, Marek
    Rubis, Pawel
    Kaznica, Magdalena
    Pieculewicz, Monika
    Cwynar, Marcin
    Grodzicki, Tomasz
    Zmudka, Krzysztof
    Tracz, Wieslawa
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 : 90 - 90
  • [9] VALIDATION OF A NEW PIEZO-ELECTRONIC DEVICE FOR NON-INVASIVE MEASUREMENT OF ARTERIAL PULSE WAVE VELOCITY
    Morales, M.
    Cuffaro, P.
    Barochiner, J.
    Rada, M.
    Alfie, J.
    Aparicio, L.
    Marin, M.
    Galarza, C.
    Waisman, G.
    [J]. JOURNAL OF HYPERTENSION, 2015, 33 : E180 - E180
  • [10] NEW METHOD FOR NON-INVASIVE MEASUREMENT OF PULSE-WAVE VELOCITY IN AORTA USING DOPPLER SONOGRAPHY
    LOHR, E
    GOBBLER, T
    SEILER, I
    REIDEMEISTER, JC
    [J]. HERZ KREISLAUF, 1977, 9 (03): : 130 - 134