Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT

被引:17
|
作者
Greco, Adelaide [1 ,3 ]
Petretta, Maria Piera [2 ]
Larobina, Michele [4 ]
Gargiulo, Sara [1 ]
Panico, Mariarosaria [4 ]
Nekolla, Stephan G. [5 ]
Esposito, Giovanni [2 ]
Petretta, Mario [2 ]
Brunetti, Arturo [1 ,3 ,4 ]
Cuocolo, Alberto [1 ,4 ]
机构
[1] Univ Naples Federico II, Dept Biomorphol & Funct Sci, I-80131 Naples, Italy
[2] Univ Naples Federico II, Dept Internal Med Cardiovasc & Immunol Sci, I-80131 Naples, Italy
[3] CEINGE Scarl, Naples, Italy
[4] CNR, Inst Biostruct & Bioimages, Naples, Italy
[5] Tech Univ Munich, Nukl Med Klin & Poliklin, Munich, Germany
关键词
Infarct size; measurement; mouse; PET/CT; F-18-FDG; EMISSION COMPUTED-TOMOGRAPHY; REPERFUSION; ISCHEMIA; RATS;
D O I
10.1007/s12350-012-9538-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study assessed the reproducibility and accuracy of 2-deoxy-2[F-18]fluoro-d-glucose (F-18-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. Mice were studied by F-18-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% +/- A 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution F-18-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [21] Clinical Assessment of the Accuracy of ICP Non-invasive Measurement
    Ragauskas, A.
    Sunokas, R.
    Zakelis, R.
    Matijosaitis, V.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2010, (08) : 31 - 34
  • [22] High-resolution picosecond acoustic microscopy for non-invasive characterization of buried interfaces
    Ramanathan S.
    Cahill D.G.
    J Mater Res, 2006, 5 (1204-1208): : 1204 - 1208
  • [23] High-resolution picosecond acoustic microscopy for non-invasive characterization of buried interfaces
    Ramanathan, Shriram
    Cahill, David G.
    JOURNAL OF MATERIALS RESEARCH, 2006, 21 (05) : 1204 - 1208
  • [24] NON-INVASIVE QUANTIFICATION OF INFARCT SIZE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY
    MELTZER, RS
    WOYTHALER, JN
    BUDA, AJ
    GRIFFIN, JC
    KERNOFF, R
    POPP, RL
    MARTIN, RP
    CIRCULATION, 1978, 58 (04) : 186 - 186
  • [25] REPRODUCIBILITY OF ULTRASOUND MEASUREMENT OF PANCREATIC SIZE WITH NEW ADVANCED HIGH-RESOLUTION DYNAMIC IMAGE SCANNERS
    DIGIANDOMENICO, V
    FILIPPONE, A
    BASILICO, R
    SPINAZZI, A
    CAPANI, F
    BONOMO, L
    JOURNAL OF CLINICAL ULTRASOUND, 1993, 21 (02) : 77 - 86
  • [26] High-resolution DNA size enrichment using a magnetic nano-platform and application in non-invasive prenatal testing
    Zhang, Bo
    Zhao, Shuting
    Wan, Hao
    Liu, Ying
    Zhang, Fei
    Guo, Xin
    Zeng, Wenqi
    Zhang, Haiyan
    Zeng, Linghua
    Qu, Jiale
    Wu, Ben-Qing
    Wan, Xinhong
    Cantor, Charles R.
    Ge, Dongliang
    ANALYST, 2020, 145 (17) : 5733 - 5739
  • [27] Non-invasive quantification of myocardial fibrosis using in-vivo high-resolution MRI in diabetic mice and correlation with arrhythmias
    Bun, S. S.
    Kober, F.
    Jacquier, A.
    Kalifa, J.
    Espinosa, L.
    Kopp, F.
    Bonzi, M. F.
    Deharo, J. C.
    Cozzone, P. J.
    Bernard, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 488 - 488
  • [28] Evaluation of the accuracy and reproducibility of non-invasive patient immobilisation for cranial stereotactic radiotherapy
    Breitsprecher, L.
    Schuerkens, J.
    Ziese, S.
    Rogers, S.
    Zepter, S.
    Bodis, S.
    Rabe, E.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1092 - 1092
  • [29] A novel non-invasive measurement of myocardial infarct size in the mouse using cardiac ultrasound tissue displacement mapping
    Donner, Daniel
    Kiriazis, Helen
    Gao, Xiaoming
    Du, Xiaojun
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2020, 140 : 6 - 7
  • [30] High-resolution, non-invasive animal tracking and reconstruction of local environment in aquatic ecosystems
    Fritz A Francisco
    Paul Nührenberg
    Alex Jordan
    Movement Ecology, 8