Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT

被引:17
|
作者
Greco, Adelaide [1 ,3 ]
Petretta, Maria Piera [2 ]
Larobina, Michele [4 ]
Gargiulo, Sara [1 ]
Panico, Mariarosaria [4 ]
Nekolla, Stephan G. [5 ]
Esposito, Giovanni [2 ]
Petretta, Mario [2 ]
Brunetti, Arturo [1 ,3 ,4 ]
Cuocolo, Alberto [1 ,4 ]
机构
[1] Univ Naples Federico II, Dept Biomorphol & Funct Sci, I-80131 Naples, Italy
[2] Univ Naples Federico II, Dept Internal Med Cardiovasc & Immunol Sci, I-80131 Naples, Italy
[3] CEINGE Scarl, Naples, Italy
[4] CNR, Inst Biostruct & Bioimages, Naples, Italy
[5] Tech Univ Munich, Nukl Med Klin & Poliklin, Munich, Germany
关键词
Infarct size; measurement; mouse; PET/CT; F-18-FDG; EMISSION COMPUTED-TOMOGRAPHY; REPERFUSION; ISCHEMIA; RATS;
D O I
10.1007/s12350-012-9538-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study assessed the reproducibility and accuracy of 2-deoxy-2[F-18]fluoro-d-glucose (F-18-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. Mice were studied by F-18-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% +/- A 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution F-18-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [1] Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT
    Adelaide Greco
    Maria Piera Petretta
    Michele Larobina
    Sara Gargiulo
    Mariarosaria Panico
    Stephan G. Nekolla
    Giovanni Esposito
    Mario Petretta
    Arturo Brunetti
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2012, 19 : 492 - 499
  • [2] Reproducibility of Quantitative Measurement of Infarct Size in Mice With High-Resolution PET/CT Imaging
    Ferro, A.
    Greco, A.
    Gargiulo, S.
    Larobina, M.
    Petretta, M. P.
    Esposito, G.
    Panico, M. R.
    Nekolla, S. G.
    Brunetti, A.
    Cuocolo, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S239 - S240
  • [3] Accurate noninvasive measurement of infarct size in mice with high-resolution PET
    Stegger, Lars
    Hoffmeier, Anne-Nadine
    Schaefers, Klaus P.
    Hermann, Sven
    Schober, Otmar
    Schaefers, Michael A.
    Theilmeier, Gregor
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (11) : 1837 - 1844
  • [4] Non-invasive imaging of coronary arteries in living mice using high-resolution echocardiography
    Gan, LM
    Wikström, J
    Bergström, G
    Wandt, B
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2004, 38 (02) : 121 - 126
  • [5] Photothermal Microimaging: A Non-Invasive and High-Resolution Imaging Technique
    Ding Jiayu
    Peng Siying
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (22)
  • [6] Simultaneous non-invasive determination of infarct size and cardiac function in mice using high-field MRI
    Yang, ZQ
    Ross, AJ
    Oshinski, JN
    Berr, SS
    French, BA
    CIRCULATION, 2000, 102 (18) : 204 - 205
  • [7] Non-invasive uroflow measurement in mice
    Leung, YYM
    Wood, RW
    Schwarz, E
    Messing, EM
    JOURNAL OF UROLOGY, 2004, 171 (04): : 451 - 451
  • [8] High-resolution CT of transplanted teeth: imaging technique and measurement accuracy
    Gahleitner, Andre
    Kuchler, Ulrike
    Homolka, Peter
    Heschl, Janina
    Watzek, Georg
    Imhof, Herwig
    EUROPEAN RADIOLOGY, 2008, 18 (12) : 2975 - 2980
  • [9] High-resolution CT of transplanted teeth: imaging technique and measurement accuracy
    André Gahleitner
    Ulrike Kuchler
    Peter Homolka
    Janina Heschl
    Georg Watzek
    Herwig Imhof
    European Radiology, 2008, 18 : 2975 - 2980
  • [10] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175