Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

被引:8
|
作者
Annoni, Andrea Daniele [1 ]
Mancini, Maria E. [1 ]
Andreini, Daniele [1 ,2 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Nobili, Enrica [1 ]
Guglielmo, Marco [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via C Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
CT angiography; dose reduction; ECG gated scan protocols; contrast agents; thoracic aorta; ROW CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGE-QUALITY; IODINE CONCENTRATION; MULTIDETECTOR CT; CHEST CT; ENHANCEMENT; REDUCTION; MDCT; KV;
D O I
10.1111/1754-9485.12608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionMultidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. MethodsTwo-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100Kvp tube voltage), Group C (Iomeprol 400 and 80Kvp tube voltage) and Group D (Iomeprol 400 and 100Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. ResultsNo significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80kV versus groups using 100kV but without differences in terms of image quality. ED was significantly lower in groups with 80kV. ConclusionsMultidetector Computed Tomography Angiography protocols using 80kV and low concentration contrast media are feasible without need of tailored injection protocols.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 50 条
  • [1] RADIATION DOSE REDUCTION BY USING 80KV MULTI DETECTOR COMPUTED TOMOGRAPHY
    Rezaeian, Panteha
    Nakanishi, Rine
    Luo, Yanting
    Alani, Anas
    Matsumoto, Suguru
    Razipour, Aryabod
    Budoff, Matthew
    CLINICAL CARDIOLOGY, 2017, 40 : 8 - 9
  • [2] Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study
    Zhang, Hong
    Ma, Yanhe
    Lyu, Jun
    Yang, Yapeng
    Yuan, Wei
    Song, Zhenchun
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5005 - 5010
  • [3] Low-Dose Carotid Computed Tomography Angiography Using Pure Iterative Reconstruction
    Moloney, Fiachra
    Murphy, Kevin P.
    Twomey, Maria
    Crush, Lee
    Canniffe, Emma M.
    McLaughlin, Patrick D.
    Moore, Niamh
    O'Keeffe, Michael
    O'Neill, Siobhan
    Manning, Brian M.
    Wyse, Gerald
    Fanning, Noel
    O'Connor, Owen J.
    Maher, Michael M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) : 833 - 839
  • [4] Comparison of Ultra low dose MDCT protocol for thoracic aorta using low tube voltage and low concentration contrast media versus standard protocol with high iodine concentration contrast media
    Annoni, A.
    Formenti, A.
    Pontone, G.
    Andreini, D.
    Ballerini, G.
    Baggiano, A.
    Nobili, E.
    Montorsi, P.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 88 - 89
  • [5] Low-Dose CT of the Patients with 80kV Coronary Angiography Bypass Grafts Using Iterative Model Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
    Luo, C. C.
    Li, T.
    Yang, L.
    Huang, Z. L.
    Li, X. P.
    Liu, B.
    Yang, T.
    Qi, Y. Q.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2019, 67 : S682 - S682
  • [6] A study on CT pulmonary angiography at low kV and low-concentration contrast medium using iterative reconstruction
    Ma, Yanhe
    Zhang, Hong
    Zhang, Yuedong
    Yu, Tilian
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (17): : 7683 - 7687
  • [7] Ultra-low radiation 70kv-coronary computed tomography angiography with low-dose contrast media using dual source computed tomography
    Komatsu, S.
    Takahashi, S.
    Yutani, C.
    Takewa, M.
    Ohara, T.
    Kodama, K.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3781 - 3781
  • [8] Radiation Dose and Image Noise Evaluation in Coronary Computed Tomography Angiography (CCTA) Using an Iterative Reconstruction Algorithm
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Stathis, George
    Alexiou, Antigoni
    Pantos, Ioannis
    Katritsis, Demosthenes G.
    Kelekis, Nikolaos L.
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (03) : 184 - 190
  • [9] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Komatsu, Sei
    Kamata, Teruaki
    Imai, Atsuko
    Ohara, Tomoki
    Takewa, Mitsuhiko
    Ohe, Ryoko
    Miyaji, Kazuaki
    Yoshida, Junichi
    Kodama, Kazuhisa
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1335 - 1340
  • [10] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Sei Komatsu
    Teruaki Kamata
    Atsuko Imai
    Tomoki Ohara
    Mitsuhiko Takewa
    Ryoko Ohe
    Kazuaki Miyaji
    Junichi Yoshida
    Kazuhisa Kodama
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1335 - 1340