Characterization of on-site digital mammography systems: Direct versus indirect conversion detectors

被引:11
|
作者
Youn, Hanbean [1 ]
Han, Jong Chul [1 ]
Yun, Seungman [1 ]
Kam, Soohwa [1 ]
Cho, Seungryong [2 ]
Kim, Ho Kyung [1 ,3 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
[3] Pusan Natl Univ, Ctr Adv Med Engn Res, Busan 609735, South Korea
基金
新加坡国家研究基金会;
关键词
Digital mammography; Cesium iodide; Amorphous selenium; MTF; NPS; DQE; Contrast; MODULATION TRANSFER-FUNCTION; PHYSICAL-CHARACTERISTICS; IMAGING PERFORMANCE; FILM MAMMOGRAPHY; RAY; SIGNAL; RESOLUTION; MTF;
D O I
10.3938/jkps.66.1926
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We investigated the performances of two digital mammography systems. The systems use a cesium-iodide (CsI) scintillator and an amorphous selenium (a-Se) photoconductor for X-ray detection and are installed in the same hospital. As physical metrics, we measured the modulationtransfer function (MTF), the noise-power spectrum (NPS), and the detective quantum efficiency (DQE). In addition, we analyzed the contrast-detail performances of the two systems by using a commercial contrast-detail phantom. The CsI-based indirect conversion detector provided better MTF and DQE performances than the a-Se-based direct conversion detector whereas the former provided a poorer NPS performance than the latter. These results are explained by the fact that the CsI-based detector used an MTF restoration preprocessing algorithm. The a-Se-based detector showed better contrast-detail performance than the CsI-based detector. We believe that the highfrequency noise characteristic of a detector is more responsible for the visibility of small details than its spatial-resolution performance.
引用
收藏
页码:1926 / 1935
页数:10
相关论文
共 50 条
  • [21] A flexible approach for the dimensioning of on-site energy conversion systems for manufacturing companies
    Gahm, Christian
    Ganschinietz, Chantal
    Denz, Florian
    Tuma, Axel
    COMPUTERS & INDUSTRIAL ENGINEERING, 2021, 159
  • [22] Phase Characterization of a 2-Path On-Site Coding Digital Beamformer
    Alwan, Elias A.
    Akhiyat, Abe
    Khalil, Waleed
    Volakis, John L.
    2014 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2014, : 1214 - 1215
  • [23] Imaging characteristics of the direct and mobile indirect digital radiographic systems
    Cho, Hyo-Min
    Kim, Hee-Joung
    Lee, Chang-Lae
    Nam, Sora
    Jung, Ji-Young
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3840 - 3846
  • [24] Measured Dose versus Organ Dose Performance in Digital Mammography Systems
    McCullagh, James B.
    Baldelli, Paola
    Phelan, Niall
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 86 - +
  • [25] Diagnostic efficacy of direct and indirect digital imaging for approximal cariesQuestion: Are direct and indirect digital imaging systems effective for diagnosis of approximal caries?
    Ji-Yun Stephanie Yeung
    Dominic Hurst
    Evidence-Based Dentistry, 2018, 19 (3) : 71 - 72
  • [26] An Investigation of Direct and Indirect Powers of DC-DC Conversion Systems
    Hofsajer, Ivan
    Letsoalo, Future
    de Beer, Arnold
    2023 IEEE 2ND INDUSTRIAL ELECTRONICS SOCIETY ANNUAL ON-LINE CONFERENCE, ONCON, 2023,
  • [27] Direct flat-panel detectors: A-Se TFT detector for full field digital mammography
    Gkanatsios, N
    MEDICAL PHYSICS, 2003, 30 (06) : 1434 - 1434
  • [28] Phase Characterization of an 8-Channel On-site Coding Receiver for Digital Beamforming
    Venkatakrishnan, Satheesh Bojja
    Akhiyat, Abe A.
    Alwan, Elias A.
    Khalil, Waleed
    Volakis, John L.
    2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 225 - 225
  • [29] Imaging characteristics of a direct conversion full-field digital mammography detector using selenium
    Lee, DL
    Yorker, JG
    Jing, ZX
    Jeromin, LS
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 43 - 47
  • [30] An experimental comparison of detector performance for direct and indirect digital radiography systems
    Samei, E
    Flynn, MJ
    MEDICAL PHYSICS, 2003, 30 (04) : 608 - 622