Detection of xenoantibodies using a simple flow cytometric assay

被引:5
|
作者
Al-Hussein, K
Al-Mukhalafi, Z
Pyle, HR
Parhar, RS
Al-Mohanna, F
Lee, J
机构
[1] King Faisal Specialist Hosp & Res Ctr, Med Res Ctr, Riyadh 11211, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Dept Biol, Riyadh 11211, Saudi Arabia
关键词
endothelial cells; flow cytometry; xenoantibodies;
D O I
10.1046/j.0908-665x.2000.00000.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Higher primates, including humans, have high levels of preexisting naturally circulating antibodies that predominantly recognize the epitope Gal (1,3-Gal), which is highly expressed on the surface of xenogenic cells. Deposition of these antibodies on the endothelial cell surface of vascularized xenografts leads to an activation of the classical pathway of the complement system, resulting in tissue ischemia and necrosis with rapid demise of the xenograft. This hyperacute rejection (HAR) is always a major barrier in xenograft transplantation and should be minimized by accurately monitoring the naturally occurring antibodies. In the present study, we utilized a simple and rapid flow cytometric (FCM) assay to monitor the presence of these naturally occurring antibodies. We found that the FCM assay is very effective in measuring human antibodies bound to the xenogenic cells, which cause cytotoxicity. This assay could be useful in the pre- and post-xenotransplantation monitoring of xenoantibodies, thus, helping in the development of strategies to block the binding of preformed human antibodies to the xenograft in order to overcome the problem of HAR.
引用
收藏
页码:172 / 175
页数:4
相关论文
共 50 条
  • [21] Value of flow cytometric assay for the detection of antisperm antibodies in women with a history of recurrent abortion
    Al-Hussein, K
    Al-Mukhalafi, Z
    Bertilsson, PA
    Jaroudi, K
    Shoukri, M
    Hollander, J
    AMERICAN JOURNAL OF REPRODUCTIVE IMMUNOLOGY, 2002, 47 (01): : 31 - 37
  • [22] A flow cytometric assay for the detection of pro-apoptotic antiretinal antibodies in human serum
    Jirawuthiworavong, GV
    Morales, SA
    Shimazaki, K
    Heckenlively, JR
    Seigel, GM
    Gordon, LK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U986 - U986
  • [23] DETECTION OF BCR-ABL FUSION PROTEINS WITH A FAST FLOW CYTOMETRIC BEAD ASSAY
    Hevessy, Zsuzsanna
    Hudak, Renata
    Kiss-Sziraki, Valeria
    Antal-Szalmas, Peter
    Udvardy, Miklos
    Szerafin, Laszlo
    Kappelmayer, Janos
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (06) : 421 - 421
  • [24] Validation of a clinically applicable flow cytometric assay for the detection of immunoglobulin associated platelets in dogs
    Shropshire, Sarah
    Dow, Steven
    Lappin, Michael
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2018, 202 : 109 - 114
  • [25] Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients
    Zhai, Juping
    Ding, Mengyuan
    Yang, Tianjie
    Zuo, Bin
    Weng, Zhen
    Zhao, Yunxiao
    He, Jun
    Wu, Qingyu
    Ruan, Changgeng
    He, Yang
    JOURNAL OF TRANSLATIONAL MEDICINE, 2017, 15
  • [26] Flow cytometric immunobead assay for the detection of BCR–ABL fusion proteins in leukemia patients
    F Weerkamp
    E Dekking
    Y Y Ng
    V H J van der Velden
    H Wai
    S Böttcher
    M Brüggemann
    A J van der Sluijs
    A Koning
    N Boeckx
    N Van Poecke
    P Lucio
    A Mendonça
    L Sedek
    T Szczepański
    T Kalina
    M Kovac
    P G Hoogeveen
    J Flores-Montero
    A Orfao
    E Macintyre
    L Lhermitte
    R Chen
    K A J Brouwer-De Cock
    A van der Linden
    A L Noordijk
    W M Comans-Bitter
    F J T Staal
    J J M van Dongen
    Leukemia, 2009, 23 : 1106 - 1117
  • [27] Response to: Flow cytometric cellediated cytotoxicity assay
    Langhans, Bettina
    Ahrendt, Manuela
    Spengler, Ulrich
    JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 318 (1-2) : 160 - 161
  • [28] Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients
    Juping Zhai
    Mengyuan Ding
    Tianjie Yang
    Bin Zuo
    Zhen Weng
    Yunxiao Zhao
    Jun He
    Qingyu Wu
    Changgeng Ruan
    Yang He
    Journal of Translational Medicine, 15
  • [29] DETECTION OF MALIGNANT EPITHELIAL CELLS USING FLOW CYTOMETRIC IMMUNOPHENOTYPING
    Arroz, Maria
    Acosta, Maria
    Pereira, Jose
    Luz, Lylliane
    Costa, Ana
    Amaro, Silvia
    Chorco, Martinha
    Junior, Esmeraldina
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2012, 82B (06) : 392 - 392
  • [30] Flow cytometric detection of HLA antibodies using a spectrum of microbeads
    Pei, R
    Lee, JH
    Chen, T
    Rojo, S
    Terasaki, PI
    HUMAN IMMUNOLOGY, 1999, 60 (12) : 1293 - 1302