Detection of xenoantibodies using a simple flow cytometric assay

被引:5
|
作者
Al-Hussein, K
Al-Mukhalafi, Z
Pyle, HR
Parhar, RS
Al-Mohanna, F
Lee, J
机构
[1] King Faisal Specialist Hosp & Res Ctr, Med Res Ctr, Riyadh 11211, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Dept Biol, Riyadh 11211, Saudi Arabia
关键词
endothelial cells; flow cytometry; xenoantibodies;
D O I
10.1046/j.0908-665x.2000.00000.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Higher primates, including humans, have high levels of preexisting naturally circulating antibodies that predominantly recognize the epitope Gal (1,3-Gal), which is highly expressed on the surface of xenogenic cells. Deposition of these antibodies on the endothelial cell surface of vascularized xenografts leads to an activation of the classical pathway of the complement system, resulting in tissue ischemia and necrosis with rapid demise of the xenograft. This hyperacute rejection (HAR) is always a major barrier in xenograft transplantation and should be minimized by accurately monitoring the naturally occurring antibodies. In the present study, we utilized a simple and rapid flow cytometric (FCM) assay to monitor the presence of these naturally occurring antibodies. We found that the FCM assay is very effective in measuring human antibodies bound to the xenogenic cells, which cause cytotoxicity. This assay could be useful in the pre- and post-xenotransplantation monitoring of xenoantibodies, thus, helping in the development of strategies to block the binding of preformed human antibodies to the xenograft in order to overcome the problem of HAR.
引用
收藏
页码:172 / 175
页数:4
相关论文
共 50 条
  • [31] Flow cytometric detection of the Golgi apparatus using antibodies to glycosyltransferases
    Felner, KM
    Niederer, E
    Berger, EG
    CYTOMETRY, 1997, 28 (01): : 50 - 57
  • [32] Evaluation of flow cytometric assay in the diagnosis of HIT
    Tardy, B.
    Montmartin, A.
    Piot, M.
    Chapelle, C.
    Akrour, M.
    Alhenc-Gelas, M.
    Maistre, E. D.
    Elalamy, I
    Fontana, P.
    Greinacher, A.
    Horellou, M-H
    Lasne, D.
    Lecompte, T.
    Legal, G.
    Lillo-LeLouet, A.
    Mullier, F.
    Nguyen, P.
    Pouplard, C.
    Toussaint-Hacquard, M.
    Tomer, A.
    Tardy, B.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 : 114 - 115
  • [33] RAPID ENHANCED FLOW CYTOMETRIC CROSSMATCH ASSAY
    Yin, Y.
    Takemura, P.
    Aguas, G.
    Hickey, M.
    Valenzuela, N. M.
    Sosa, R. A.
    Butler, C.
    Zhang, J.
    Reed, E.
    HUMAN IMMUNOLOGY, 2021, 82 : 166 - 167
  • [34] A simple rapid flow cytometric method for detection of porcine cell surface markers.
    Stabel, TJ
    Bolin, SR
    Pesch, BA
    Rahner, T
    FASEB JOURNAL, 2000, 14 (06): : A1236 - A1236
  • [35] Rapid Multiplexed Flow Cytometric Assay for Botulinum Neurotoxin Detection Using an Automated Fluidic Microbead-Trapping Flow Cell for Enhanced Sensitivity
    Ozanich, Richard M., Jr.
    Bruckner-Lea, Cynthia J.
    Warner, Marvin G.
    Miller, Keith
    Antolick, Kathryn C.
    Marks, James D.
    Lou, Jianlong
    Grate, Jay W.
    ANALYTICAL CHEMISTRY, 2009, 81 (14) : 5783 - 5793
  • [36] A SIMPLE AND SENSITIVE FLOW CYTOMETRIC ASSAY FOR THE DETERMINATION OF THE CYTOTOXIC ACTIVITY OF HUMAN NATURAL-KILLER-CELLS
    RADOSEVIC, K
    GARRITSEN, HSP
    VANGRAFT, M
    DEGROOTH, BG
    GREVE, J
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) : 81 - 89
  • [37] A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes
    Tsagarakis, Nikolaos J.
    Paterakis, George
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2012, 82B (04) : 259 - 263
  • [38] A SIMPLE PRESERVATIVE FOR FLOW CYTOMETRIC DNA ANALYSIS
    ALANEN, KA
    KLEMI, PJ
    TAIMELA, S
    JOENSUU, H
    CYTOMETRY, 1989, 10 (01): : 86 - 89
  • [39] A novel flow cytometric assay for rapid detection of extended-spectrum beta-lactamases
    Faria-Ramos, I.
    Espinar, M. J.
    Rocha, R.
    Santos-Antunes, J.
    Rodrigues, A. G.
    Canton, R.
    Pina-Vaz, C.
    CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (01) : E8 - E15
  • [40] A novel two-color flow cytometric assay for the detection of Cryptosporidium in environmental water samples
    Ferrari, BC
    Vesey, G
    Davis, KA
    Gauci, M
    Veal, D
    CYTOMETRY, 2000, 41 (03): : 216 - 222