Flow cytometric detection of HLA antibodies using a spectrum of microbeads

被引:112
|
作者
Pei, R
Lee, JH
Chen, T
Rojo, S
Terasaki, PI
机构
[1] One Lambda Inc, Res Dept, Canoga Park, CA USA
[2] Terasaki Fdn, Los Angeles, CA USA
关键词
HLA; antibodies; flow cytometry; microbeads; PRA;
D O I
10.1016/S0198-8859(99)00121-4
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We describe here the use of HLA antigen coated beads for specificity and class determination of HLA antibodies by flow cytometry. The HLA specificity of antibodies was determined by use of beads containing eight levels of fluorescence. HLA antigens isolated from eight cultured cells were coated onto these beads so that each bead was the equivalent of one cell. By using Four sets of eight beads, an equivalent of 32 cells could be examined in four test tubes. A total of 76 class I and 25 class II specificities could be determined by the 32 class I bead-panel and 32 class II bead-panel used, respectively. We noted no cross-reactivity of reactions between class I and II. The sensitivity of the test was shown to be higher than that of the standard cytotoxicity by dilution experiments and detection of additional cross-reacting antigens. By use of these coated beads, we achieved improved standardized detection of HLA antibodies. Antigen-coated beads have several advantages over the use of spleens or lymphocytes. (a) A highly selected panel of antigens can be routinely used. (b) Class I and class II antibodies can be readily distinguished from each other, a en when they are present as mixtures in one serum. (c) Non-HLA antibodies are not detected because the beads do nor have any other antigens than HLA on them. (d) The quantity of antigens coated on beads is more uniform than that found in cells from different individuals. (e) Beads are more convenient for storage and daily use. (C) American Society for Histocompatibility and Immunogenetics, 1999, Published by Elsevier Science Inc.
引用
收藏
页码:1293 / 1302
页数:10
相关论文
共 50 条
  • [1] Flow cytometric detection of complement-activating HLA antibodies
    Schönemann, C
    Lachmann, N
    Kiesewetter, H
    Salama, A
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2004, 62B (01) : 39 - 45
  • [2] CORRELATION OF FLOW CYTOMETRIC CROSSMATCH AND LUMINEX FOR THE DETECTION OF HLA ANTIBODIES
    Watson, Narelle
    Weston, Lyanne
    Abou-Daher, Frederika
    Gavin, Rebecca
    Rosales, Brenda
    Bryant, Jenny
    HUMAN IMMUNOLOGY, 2009, 70 : S48 - S48
  • [3] IS THERE CORRELATION OF FLOW CYTOMETRIC CROSSMATCH AND LUMINEX FOR THE DETECTION OF HLA ANTIBODIES?
    Narelle, Watson
    Lyanne, Weston
    Frederika, Abou-Daher
    Rebecca, Gavin
    Brenda, Rosales
    Jenny, Bryant
    IMMUNOLOGY AND CELL BIOLOGY, 2009, 87 (06): : A3 - A3
  • [4] Flow cytometric detection of complement-activating HLA antibodies
    Lachmman, N
    Schönemann, C
    Salama, A
    GENES AND IMMUNITY, 2005, 6 : S53 - S53
  • [5] Flow cytometric crossmatch results and HLA antibodies detected by single HLA coated microbeads luminex assay in renal transplantation
    Paterakis, G. S.
    Iniotaki-Theodorakis, A.
    Skoumi, D.
    Apostolaki, M.
    Stavropoulos-Giokas, C.
    TISSUE ANTIGENS, 2007, 69 (05): : 489 - 490
  • [6] Flow cytometric detection of the Golgi apparatus using antibodies to glycosyltransferases
    Felner, KM
    Niederer, E
    Berger, EG
    CYTOMETRY, 1997, 28 (01): : 50 - 57
  • [7] Flow cytometric detection of HLA-specific antibodies as a predictor of heart allograft rejection
    Tambur, AR
    Bray, RA
    Takemoto, SK
    Mancini, M
    Costanzo, MR
    Kobashigawa, JA
    D'Amico, CL
    Kanter, KR
    Berg, A
    Vega, JD
    Smith, AL
    Roggero, AL
    Ortegel, JW
    Wilmoth-Hosey, L
    Cecka, JM
    Gebel, HM
    TRANSPLANTATION, 2000, 70 (07) : 1055 - 1059
  • [8] DIFFERENTIAL DETECTION OF GLYCOSYLATION OF HLA DONOR SPECIFIC ANTIBODIES (DSA) USING SINGLE ANTIGEN MICROBEADS
    Chang, Youngil
    Lemp, Nathan
    Cicciarelli, James C.
    Min, David I.
    HUMAN IMMUNOLOGY, 2018, 79 : 37 - 37
  • [9] DETECTION OF GRANULOCYTE ANTIBODIES USING FLOW CYTOMETRIC ANALYSIS OF LEUKOCYTE IMMUNOFLUORESCENCE
    VEYS, PA
    GUTTERIDGE, CN
    MACEY, M
    ORD, J
    NEWLAND, AC
    VOX SANGUINIS, 1989, 56 (01) : 42 - 47
  • [10] FLOW-CYTOMETRIC DETECTION OF PLATELET ANTIBODIES
    LAZARCHICK, J
    HALL, S
    GENCO, PV
    PONZIO, AD
    BURDASH, NM
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1985, 15 (04): : 336 - 336