Biorealistic Control of Hand Prosthesis Augments Functional Performance of Individuals With Amputation

被引:10
|
作者
Luo, Qi [1 ]
Niu, Chuanxin M. [1 ,2 ,3 ]
Chou, Chih-Hong [1 ,2 ]
Liang, Wenyuan [4 ]
Deng, Xiaoqian [5 ]
Hao, Manzhao [1 ,2 ]
Lan, Ning [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Lab Neurorehabil Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Rehabil Med, Shanghai, Peoples R China
[4] Natl Res Ctr Rehabil Tech Aids, Beijing, Peoples R China
[5] Guangdong Work Injury Rehabil Hosp, Guangzhou, Peoples R China
基金
国家重点研发计划;
关键词
biorealistic control; neuromuscular reflex; neuromorphic computation; tendon-driven prosthesis; hand grasp; UPPER-LIMB LOSS; MECHANICAL MODEL; MUSCLE-STIFFNESS; TENDON; FEEDBACK; REFLEX; INFORMATION; VALIDATION; BOX;
D O I
10.3389/fnins.2021.783505
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The human hand has compliant properties arising from muscle biomechanics and neural reflexes, which are absent in conventional prosthetic hands. We recently proved the feasibility to restore neuromuscular reflex control (NRC) to prosthetic hands using real-time computing neuromorphic chips. Here we show that restored NRC augments the ability of individuals with forearm amputation to complete grasping tasks, including standard Box and Blocks Test (BBT), Golf Balls Test (GBT), and Potato Chips Test (PCT). The latter two were more challenging, but novel to prosthesis tests. Performance of a biorealistic controller (BC) with restored NRC was compared to that of a proportional linear feedback (PLF) controller. Eleven individuals with forearm amputation were divided into two groups: one with experience of myocontrol of a prosthetic hand and another without any. Controller performances were evaluated by success rate, failure (drop/break) rate in each grasping task. In controller property tests, biorealistic control achieved a better compliant property with a 23.2% wider range of stiffness adjustment than that of PLF control. In functional grasping tests, participants could control prosthetic hands more rapidly and steadily with neuromuscular reflex. For participants with myocontrol experience, biorealistic control yielded 20.4, 39.4, and 195.2% improvements in BBT, GBT, and PCT, respectively, compared to PLF control. Interestingly, greater improvements were achieved by participants without any myocontrol experience for BBT, GBT, and PCT at 27.4, 48.9, and 344.3%, respectively. The functional gain of biorealistic control over conventional control was more dramatic in more difficult grasp tasks of GBT and PCT, demonstrating the advantage of NRC. Results support the hypothesis that restoring neuromuscular reflex in hand prosthesis can improve neural motor compatibility to human sensorimotor system, hence enabling individuals with amputation to perform delicate grasps that are not tested with conventional prosthetic hands.
引用
收藏
页数:17
相关论文
共 50 条
  • [42] The Effect of Prosthesis Use on Hand Mental Rotation After Unilateral Upper-Limb Amputation
    Guo, Xiaoli
    Lin, Zixuan
    Lyu, Yuanyuan
    Bekrater-Bodmann, Robin
    Flor, Herta
    Tong, Shanbao
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (11) : 2046 - 2053
  • [43] Effects of extended stance time on a powered knee prosthesis and gait symmetry on the lateral control of balance during walking in individuals with unilateral amputation
    Andrea Brandt
    He ( Helen) Huang
    Journal of NeuroEngineering and Rehabilitation, 16
  • [44] Impedance Control Strategies for Enhancing Sloped and Level Walking Capabilities for Individuals with Transfemoral Amputation Using a Powered Multi-Joint Prosthesis
    Bhakta, Krishan
    Camargo, Jonathan
    Kunapuli, Pratik
    Childers, Lee
    Young, Aaron
    MILITARY MEDICINE, 2020, 185 : 490 - 499
  • [45] Effects of extended stance time on a powered knee prosthesis and gait symmetry on the lateral control of balance during walking in individuals with unilateral amputation
    Brandt, Andrea
    Huang, He
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (01)
  • [46] MYOELECTRIC CONTROL SYSTEM FOR ARM-HAND PROSTHESIS
    STEIN, A
    ELECTRONICS LETTERS, 1971, 7 (10) : 238 - &
  • [47] Development of a hand prosthesis control system with tactile feedback
    Yatsun, S. F.
    Malchikov, A. V.
    Rukavitsyn, A. N.
    BIOMEDICAL ENGINEERING, 2024, 58 (01) : 10 - 13
  • [48] Functional use of esthetic hand prosthesis: A patient's perspective
    Leow, Michael E. L.
    Das De, Soumen
    Lim, Ambrose K. Y.
    Puhaindran, Mark E.
    Chong, Alphonsus K. S.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2024, 48 (04) : 466 - 469
  • [49] Spike Quaternion Neural Networks Control for a Hand prosthesis
    Lizrraga-Rodrguez, Jorge
    Lechuga-Gutierrez, Luis
    Bayro-Corrochano, Eduardo
    2018 IEEE LATIN AMERICAN CONFERENCE ON COMPUTATIONAL INTELLIGENCE (LA-CCI), 2018,
  • [50] Myoelectric functional hand prosthesis for total brachial plexus injury
    Nadi, Mustafa
    Midha, Rajiv
    JOURNAL OF NEUROSURGERY, 2017, 127 (05) : 1160 - 1162