Biorealistic Control of Hand Prosthesis Augments Functional Performance of Individuals With Amputation

被引:10
|
作者
Luo, Qi [1 ]
Niu, Chuanxin M. [1 ,2 ,3 ]
Chou, Chih-Hong [1 ,2 ]
Liang, Wenyuan [4 ]
Deng, Xiaoqian [5 ]
Hao, Manzhao [1 ,2 ]
Lan, Ning [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Lab Neurorehabil Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Rehabil Med, Shanghai, Peoples R China
[4] Natl Res Ctr Rehabil Tech Aids, Beijing, Peoples R China
[5] Guangdong Work Injury Rehabil Hosp, Guangzhou, Peoples R China
基金
国家重点研发计划;
关键词
biorealistic control; neuromuscular reflex; neuromorphic computation; tendon-driven prosthesis; hand grasp; UPPER-LIMB LOSS; MECHANICAL MODEL; MUSCLE-STIFFNESS; TENDON; FEEDBACK; REFLEX; INFORMATION; VALIDATION; BOX;
D O I
10.3389/fnins.2021.783505
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The human hand has compliant properties arising from muscle biomechanics and neural reflexes, which are absent in conventional prosthetic hands. We recently proved the feasibility to restore neuromuscular reflex control (NRC) to prosthetic hands using real-time computing neuromorphic chips. Here we show that restored NRC augments the ability of individuals with forearm amputation to complete grasping tasks, including standard Box and Blocks Test (BBT), Golf Balls Test (GBT), and Potato Chips Test (PCT). The latter two were more challenging, but novel to prosthesis tests. Performance of a biorealistic controller (BC) with restored NRC was compared to that of a proportional linear feedback (PLF) controller. Eleven individuals with forearm amputation were divided into two groups: one with experience of myocontrol of a prosthetic hand and another without any. Controller performances were evaluated by success rate, failure (drop/break) rate in each grasping task. In controller property tests, biorealistic control achieved a better compliant property with a 23.2% wider range of stiffness adjustment than that of PLF control. In functional grasping tests, participants could control prosthetic hands more rapidly and steadily with neuromuscular reflex. For participants with myocontrol experience, biorealistic control yielded 20.4, 39.4, and 195.2% improvements in BBT, GBT, and PCT, respectively, compared to PLF control. Interestingly, greater improvements were achieved by participants without any myocontrol experience for BBT, GBT, and PCT at 27.4, 48.9, and 344.3%, respectively. The functional gain of biorealistic control over conventional control was more dramatic in more difficult grasp tasks of GBT and PCT, demonstrating the advantage of NRC. Results support the hypothesis that restoring neuromuscular reflex in hand prosthesis can improve neural motor compatibility to human sensorimotor system, hence enabling individuals with amputation to perform delicate grasps that are not tested with conventional prosthetic hands.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Quantitative functional evaluation of a 3D-printed silicone-embedded prosthesis for partial hand amputation: A case report
    Alvial, Pilar
    Bravo, Gabriela
    Paz Bustos, Maria
    Moreno, Gabriel
    Alfaro, Roberto
    Cancino, Renata
    Cristobal Zagal, Juan
    JOURNAL OF HAND THERAPY, 2018, 31 (01) : 129 - 136
  • [22] Press-Fit Bone-Anchored Prosthesis for Individuals with Transtibial Amputation
    Frolke, Jan Paul M.
    Atallah, Robin
    Leijendekkers, Ruud
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2024, 14 (02):
  • [23] Functional rehabilitation after transfemoral amputation. Shaft prosthesis or endo-exo prosthesis?
    Richter, Katherina
    Krause, Katharina
    Rotter, Robert
    Fischer, Dagmar-C
    Aschoff, Horst-H
    Mittlmeier, Thomas
    UNFALLCHIRURGIE, 2022, 125 (04): : 266 - 273
  • [24] Gait Analysis in Individuals with Transtibial Amputation Walking on Sand: Comparing Everyday Prosthesis with a Water-Activity Prosthesis
    van den Berg, Maayken E. L.
    Barr, Christopher J.
    Cavenett, Sally
    Crotty, Maria
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2020, 32 (02) : 107 - 115
  • [25] Golf hand prosthesis performance of transradial amputees
    Carey, Stephanie L.
    Wernke, Matthew M.
    Lura, Derek J.
    Kahle, Jason T.
    Dubey, Rajiv V.
    Highsmith, M. Jason
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2015, 39 (03) : 244 - 249
  • [26] FLUIDIC POWER AND CONTROL FOR HAND ORTHOSIS AND PROSTHESIS
    TRUONG, XT
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1973, 54 (02): : 91 - 96
  • [27] Progress in the biomechatronic design and control of a hand prosthesis
    Wang, Xinqing
    Liu, Yiwei
    Yang, Dapeng
    Li, Nan
    Jiang, Li
    Liu, Hong
    IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 5880 - 5885
  • [28] Custom, rapid prototype thumb prosthesis for partial-hand amputation: A case report
    Swartz, Ashley Quinn
    Turner, Kristi
    Miller, Laura
    Kuiken, Todd
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2018, 42 (02) : 187 - 190
  • [29] Implementation of EMG Signals for Hand Prosthesis Control
    Witczak, Mateusz
    Majkowski, Andrzej
    Kolodziej, Marcin
    2024 25TH INTERNATIONAL CONFERENCE ON COMPUTATIONAL PROBLEMS OF ELECTRICAL ENGINEERING, CPEE 2024, 2024,
  • [30] Affordable passive 3D-printed prosthesis for persons with partial hand amputation
    Alturkistani, Raghad
    Kavin, A.
    Devasahayam, Suresh
    Thomas, Raji
    Colombini, Esther L.
    Cifuentes, Carlos A.
    Homer-Vanniasinkam, Shervanthi
    Wurdemann, Helge A.
    Moazen, Mehran
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2020, 44 (02) : 92 - 98