Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase

被引:10
|
作者
Balkatzopoulou, P. [1 ]
Fasoula, S. [1 ]
Gika, H. [2 ]
Nikitas, P. [1 ]
Pappa-Louisi, A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Chem Engn, Thessaloniki 54124, Greece
关键词
Mixed-mode stationary phase; RP and HILIC gradients; Modeling dual gradient elution; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN URINE; SEPARATION; ELUTION; METABOLITES; OPTIMIZATION; COLUMNS; PH;
D O I
10.1016/j.chroma.2015.03.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (In k) upon the organic modifier volume fraction (phi). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [31] Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized capillary electrochromatography
    Wang, Jiabin
    Ding, Changying
    Xiao, Jianhua
    Jia, Wenchao
    Chen, Yongxuan
    Lin, Xucong
    Xie, Zenghong
    ELECTROPHORESIS, 2018, 39 (12) : 1504 - 1511
  • [32] Preparation of a mixed-mode hydrophilic interaction/anion-exchange polymeric monolithic stationary phase for capillary liquid chromatography of polar analytes
    Lin, Jian
    Lin, Jia
    Lin, Xucong
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (05) : 801 - 806
  • [33] STATIONARY PHASE CONTRIBUTIONS TO RETENTION IN HIGH-PERFORMANCE ANION-EXCHANGE PROTEIN CHROMATOGRAPHY - LIGAND DENSITY AND MIXED-MODE EFFECTS
    KOPACIEWICZ, W
    ROUNDS, MA
    REGNIER, FE
    JOURNAL OF CHROMATOGRAPHY, 1985, 318 (02): : 157 - 172
  • [34] Preparation of a reversed-phase/anion-exchange mixed-mode spherical sorbent by Pickering emulsion polymerization for highly selective solid-phase extraction of acidic pharmaceuticals from wastewater
    Huang, Chaonan
    Li, Yun
    Yang, Jiajia
    Peng, Junyu
    Jin, Jing
    Dhanjai
    Wang, Jincheng
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1521 : 1 - 9
  • [35] Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column
    Hao, Chunyan
    Morse, David
    Morra, Franca
    Zhao, Xiaoming
    Yang, Paul
    Nunn, Brian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (33) : 5638 - 5643
  • [36] High stability amino-derived reversed-phase/anion-exchange mixed-mode phase based on polysilsesquioxane microspheres for simultaneous separation of compound drugs
    Shi, Jinjin
    Zhang, Lixuan
    Huo, Zhixia
    Chen, Lei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 203
  • [37] Dendrimer-functionalized mesoporous silica as a reversed-phase/anion-exchange mixed-mode sorbent for solid phase extraction of acid drugs in human urine
    Li, Yun
    Yang, Jiajia
    Huang, Chaonan
    Wang, Longxing
    Wang, Jincheng
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1392 : 28 - 36
  • [38] Preparation and retention mechanism of a mixed-mode reversed-phase/strong-cationic-exchange chromatographic packing
    Peng Xitian
    Wang Jue
    Feng Yuqi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (04) : 329 - 334
  • [39] Performance evaluation of 2-undecylimidazole/propyl methacrylate bifunctional silica gel for mixed-mode reversed-phase/anion-exchange chromatography
    Hu, Zhefei
    Jiang, Yanhao
    Cao, Panpan
    Liu, Yanjuan
    Zhang, Yuefei
    Chen, Wei
    Tang, Sheng
    MICROCHEMICAL JOURNAL, 2023, 191
  • [40] A comparison of micropellicular anion-exchange and reversed-phase stationary phases for HPLC analysis of oligonucleotides
    Huber, CG
    Stimpf, E
    Oefner, PJ
    Bonn, GK
    LC GC NORTH AMERICA, 1996, 14 (02) : 114 - +