Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase

被引:10
|
作者
Balkatzopoulou, P. [1 ]
Fasoula, S. [1 ]
Gika, H. [2 ]
Nikitas, P. [1 ]
Pappa-Louisi, A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Chem Engn, Thessaloniki 54124, Greece
关键词
Mixed-mode stationary phase; RP and HILIC gradients; Modeling dual gradient elution; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN URINE; SEPARATION; ELUTION; METABOLITES; OPTIMIZATION; COLUMNS; PH;
D O I
10.1016/j.chroma.2015.03.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (In k) upon the organic modifier volume fraction (phi). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [21] Alternative high-performance liquid chromatographic peptide separation and purification concept using a new mixed-mode reversed-phase/weak anion-exchange type stationary phase
    Nogueira, R
    Lämmerhofer, M
    Lindner, W
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 158 - 169
  • [22] Preparation and retention mechanism of a mixed-mode reversed-phase/weak-cationic-exchange chromatographic packing
    Peng Xitian
    Feng Yuqi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (04) : 381 - 387
  • [23] Dicationic imidazolium ionic liquid modified silica as a novel reversed-phase/anion-exchange mixed-mode stationary phase for high-performance liquid chromatography
    Sun, Min
    Feng, Juanjuan
    Wang, Xiaojiao
    Duan, Huimin
    Li, Leilei
    Luo, Chuannan
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (16) : 2153 - 2159
  • [24] A new weak an ion-exchange/reversed-phase mixed-mode stationary phase for simultaneous separation of basic, acidic, and neutral pharmaceuticals
    Liu, Xiaodong
    Pohl, Christopher
    LC GC NORTH AMERICA, 2007, : 65 - 65
  • [25] Probing selectivity of mixed-mode reversed-phase/weak-anion-exchange liquid chromatography to advance method development
    Dores-Sousa, Jose Luis
    De Vos, Jelle
    Kok, Wim Th
    Eeltink, Sebastiaan
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1570 : 75 - 81
  • [26] A mixed-mode reversed-phase/strong-anion-exchange stationary phase: Analyte-retention stability and application in the analysis of nonsteroidal anti-inflammatory drugs
    Xu, Meng
    Wu, Zhenwei
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1722
  • [27] HPLC Separation of Acetaminophen and its Impurities Using A Mixed-mode Reversed-Phase/Cation Exchange Stationary Phase
    Calinescu, Octavian
    Badea, Irinel A.
    Vladescu, Luminita
    Meltzer, Viorica
    Pincu, Elena
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (04) : 335 - 342
  • [28] Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography
    Nogueira, Raquel
    Lubda, Dieter
    Leitner, Alexander
    Bicker, Wolfgang
    Maier, Norbert M.
    Laemmerhofer, Michael
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 966 - 978
  • [29] A Weak Cation-Exchange, Reversed-Phase Mixed-Mode HPLC Column and its Applications
    Liu, Xiaodong
    Pohl, Christopher
    AMERICAN LABORATORY, 2009, 41 (05) : 26 - +
  • [30] THE CHROMATOGRAPHIC PROPERTIES OF A MIXED-BED STATIONARY-PHASE COMBINING REVERSED-PHASE AND STRONG ANION-EXCHANGE PROPERTIES
    DAVIS, PJ
    RUANE, RJ
    WILSON, ID
    CHROMATOGRAPHIA, 1993, 37 (1-2) : 60 - 64