Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase

被引:10
|
作者
Balkatzopoulou, P. [1 ]
Fasoula, S. [1 ]
Gika, H. [2 ]
Nikitas, P. [1 ]
Pappa-Louisi, A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Chem Engn, Thessaloniki 54124, Greece
关键词
Mixed-mode stationary phase; RP and HILIC gradients; Modeling dual gradient elution; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN URINE; SEPARATION; ELUTION; METABOLITES; OPTIMIZATION; COLUMNS; PH;
D O I
10.1016/j.chroma.2015.03.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (In k) upon the organic modifier volume fraction (phi). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [1] Investigation on the Retention and Separation of Glucosinolates With a Mixed-Mode Reversed-Phase/Weak Anion-Exchange Column
    Li, Yanfang
    Chen, Pei
    Zhang, Mengliang
    Sun, Jianghao
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)
  • [2] Open tubular columns with mixed-mode reversed-phase and weak anion-exchange stationary phase for capillary electrochromatography
    Lei, Jie
    Zhang, Xiangmin
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (12) : 1996 - 2002
  • [3] Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles
    Walter, Thomas H.
    Alden, Bonnie A.
    Field, Jessica A.
    Lawrence, Nicole L.
    Osterman, Donna L.
    Patel, Amit, V
    DeLoffi, Maureen A.
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (05) : 1005 - 1014
  • [4] Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles
    Waters Corporation, Milford
    MA, United States
    J. Sep. Sci., 1615, 5 (1005-1014):
  • [5] A weak anion-exchange/reversed-phase mixed-mode HPLC column and its applications
    Liu, Xiaodong
    Pohl, Christopher
    AMERICAN LABORATORY, 2007, 39 (18) : 22 - +
  • [6] Benzimidazole modified silica as a novel reversed-phase and anion-exchange mixed-mode stationary phase for HPLC
    Sun, Min
    Feng, Juanjuan
    Luo, Chuannan
    Liu, Xia
    Jiang, Shengxiang
    TALANTA, 2013, 105 : 135 - 141
  • [7] A new weak anion-exchange/reversed-phase mixed-mode stationary phase for simultaneous separation of basic, acidic and neutral pharmaceuticals
    Liu, Xiaodong
    Pohl, Christopher
    LC GC EUROPE, 2007, : 33 - 33
  • [8] Synthetic oligonucleotide separations by mixed-mode reversed-phase/weak anion-exchange liquid chromatography
    Zimmermann, Aleksandra
    Greco, Roberto
    Walker, Isabel
    Horak, Jeannie
    Cavazzini, Alberto
    Laemmerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1354 : 43 - 55
  • [9] Surface charge fine tuning of reversed-phase/weak anion-exchange type mixed-mode stationary phases for milder elution conditions
    Zimmermann, Aleksandra
    Horak, Jeannie
    Sanchez-Munoz, Orlando L.
    Laemmerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 189 - 200
  • [10] A novel reversed-phase and weak anion-exchange mixed-mode stationary phase based on horizontal polar-copolymerized approach for separation of small organic molecules and inorganic anions
    Song, Qingguo
    Zhao, Kailou
    Xia, Hongjun
    Liu, Jiawei
    Bai, Quan
    TALANTA, 2019, 197 : 592 - 598