A comparison on three neutron-gamma discrimination methods used with NE213, UGLLT and UGAB scintillators

被引:4
|
作者
Lotfi, Y. [1 ]
Moussavi-Zarandi, S. A. [1 ]
Ghal-Eh, N. [2 ,3 ]
Bayat, E. [4 ]
机构
[1] Amirkabir Univ Technol, Dept Energy Engn & Phys, Tehran 158754413, Iran
[2] Damghan Univ, Sch Phys, Damghan 3671641167, Iran
[3] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad 917751436, Razavi Khorasan, Iran
[4] AEOI, Nucl Sci & Technol Res Ctr, Tehran 141551339, Iran
关键词
Liquid scintillator; NE213; UGLLT; UGAB; FoM; Zero-cross method; Charge integration method; Filtered charge integration method;
D O I
10.1016/j.radphyschem.2020.108701
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Liquid organic scintillators are widely used in radiation measurements. NE213 (or its equivalent, BC-501A) in neutron-gamma discrimination (NGD) and two new scintillators, UGLLT and UGAB, in alpha-beta discrimination are two common examples. In this paper, the NGD capabilities of these three scintillators were studied and their figure-of-merits (FoMs) were measured for comparison. The three different NGD methods used in this study were zero-cross method (ZCM), charge integration method (CIM) and filtered charge integration method (FCIM), where ZCM was analog and the two other methods were digital. A 1.1 mu Ci point Na-22 gamma ray source and 100 mCi cylindrical Am-241-Be neutron source (3.5 cm diameter by 5 cm length) were used for the energy calibration and the NGD, respectively. The FoM values for NE213, UGLLT and UGAB at 100 keVee discrimination bias (i.e., the preset threshold voltage, generally expressed in keVee unit, upon which the generated pulse-heights are recorded) using ZCM, CIM and FCIM methods were (1.060 +/- 0.037, 1.430 +/- 0.040, 1.70 +/- 0.054), (0.910 +/- 0.029, 1.270 +/- 0.018, 1.460 +/- 0.027) and (0.890 +/- 0.027, 1.200 +/- 0.020, 1.460 +/- 0.026), respectively. Although UGAB scintillator exhibits the least discrimination quality, one can choose an appropriate neutrongamma discrimination method to improve its FoM. The low-temperature flammability, toxicity and high-evaporation properties of NE213 scintillator may motivate some researchers to use UGLLT and UGAB scintillators as alternatives to NE213, however, by selecting the most efficient discrimination method.
引用
收藏
页数:8
相关论文
共 43 条
  • [41] Improvement of Energy Resolution and Neutron-Gamma Discrimination of NaI:Tl,6Li Single Crystal Scintillators by Ca2+ and Sr2+ Co-Doping
    Wang, Jingkang
    Wang, Chenger
    Li, Huanyin
    Shi, Jian
    Wen, Xuemin
    Shan, Chenyu
    Ren, Guohao
    Sun, Xilei
    Wu, Yuntao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (05) : 840 - 846
  • [42] Comparison and limitations of three different bulk etch rate measurement methods used for gamma irradiated PM-355 detectors
    Fazal-ur-Rehman
    Abu-Jarad, F
    Al-Jarallah, MI
    Farhat, M
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 617 - 623
  • [43] A comparison of three genetic methods used for stock discrimination of orange roughy, Hoplostethus atlanticus: allozymes, mitochondrial DNA, and random amplified polymorphic DNA
    Smith, PJ
    Benson, PG
    McVeagh, SM
    FISHERY BULLETIN, 1997, 95 (04): : 800 - 811