A comparison on three neutron-gamma discrimination methods used with NE213, UGLLT and UGAB scintillators

被引:4
|
作者
Lotfi, Y. [1 ]
Moussavi-Zarandi, S. A. [1 ]
Ghal-Eh, N. [2 ,3 ]
Bayat, E. [4 ]
机构
[1] Amirkabir Univ Technol, Dept Energy Engn & Phys, Tehran 158754413, Iran
[2] Damghan Univ, Sch Phys, Damghan 3671641167, Iran
[3] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad 917751436, Razavi Khorasan, Iran
[4] AEOI, Nucl Sci & Technol Res Ctr, Tehran 141551339, Iran
关键词
Liquid scintillator; NE213; UGLLT; UGAB; FoM; Zero-cross method; Charge integration method; Filtered charge integration method;
D O I
10.1016/j.radphyschem.2020.108701
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Liquid organic scintillators are widely used in radiation measurements. NE213 (or its equivalent, BC-501A) in neutron-gamma discrimination (NGD) and two new scintillators, UGLLT and UGAB, in alpha-beta discrimination are two common examples. In this paper, the NGD capabilities of these three scintillators were studied and their figure-of-merits (FoMs) were measured for comparison. The three different NGD methods used in this study were zero-cross method (ZCM), charge integration method (CIM) and filtered charge integration method (FCIM), where ZCM was analog and the two other methods were digital. A 1.1 mu Ci point Na-22 gamma ray source and 100 mCi cylindrical Am-241-Be neutron source (3.5 cm diameter by 5 cm length) were used for the energy calibration and the NGD, respectively. The FoM values for NE213, UGLLT and UGAB at 100 keVee discrimination bias (i.e., the preset threshold voltage, generally expressed in keVee unit, upon which the generated pulse-heights are recorded) using ZCM, CIM and FCIM methods were (1.060 +/- 0.037, 1.430 +/- 0.040, 1.70 +/- 0.054), (0.910 +/- 0.029, 1.270 +/- 0.018, 1.460 +/- 0.027) and (0.890 +/- 0.027, 1.200 +/- 0.020, 1.460 +/- 0.026), respectively. Although UGAB scintillator exhibits the least discrimination quality, one can choose an appropriate neutrongamma discrimination method to improve its FoM. The low-temperature flammability, toxicity and high-evaporation properties of NE213 scintillator may motivate some researchers to use UGLLT and UGAB scintillators as alternatives to NE213, however, by selecting the most efficient discrimination method.
引用
收藏
页数:8
相关论文
共 43 条
  • [21] USE OF LIQUID SCINTILLATORS NE214 IN A NEUTRON-FLIGHT TIME SPECTROMETER WITH SIMPLE NEUTRON-GAMMA DISTINCTION
    MULLER, WD
    ALDEFELD, B
    LANGKAU, R
    NUKLEONIK, 1968, 11 (04): : 208 - +
  • [22] Evaluating four neutron-gamma discrimination methods with EJ-301 scintillator
    Van Chuan Phan
    Xuan Hai Nguyen
    Analog Integrated Circuits and Signal Processing, 2019, 98 : 75 - 84
  • [23] Evaluating four neutron-gamma discrimination methods with EJ-301 scintillator
    Phan Van Chuan
    Nguyen Xuan Hai
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2019, 98 (01) : 75 - 84
  • [24] A SYSTEM OF LARGE LIQUID SCINTILLATION COUNTERS USED WITH A SIMPLIFIED NEUTRON-GAMMA DISCRIMINATION TECHNIQUE
    BERTIN, A
    VITALE, A
    PLACCI, A
    NUCLEAR INSTRUMENTS & METHODS, 1969, 68 (01): : 24 - &
  • [25] COMPARATIVE-STUDY OF N-GAMMA DISCRIMINATION PROPERTIES OF SCINTILLATORS NE213, C6H6, C6D6 AND STILBENE
    AHMED, M
    NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (02): : 255 - 257
  • [26] Fluorescent 1,8-naphthalimides-containing polymers as plastic scintillators. An attempt for neutron-gamma discrimination
    Hamel, Matthieu
    Simic, Vesna
    Normand, Stephane
    REACTIVE & FUNCTIONAL POLYMERS, 2008, 68 (12): : 1671 - 1681
  • [27] Discrimination methods between neutron and gamma rays for boron loaded plastic scintillators
    Normand, S
    Mouanda, B
    Haan, S
    Louvel, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 342 - 350
  • [28] A Review of Neutron-Gamma-Ray Discrimination Methods Using Organic Scintillators
    Ahnouz, Imane
    Arahmane, Hanan
    Sebihi, Rajaa
    NUCLEAR SCIENCE AND ENGINEERING, 2024, 198 (12) : 2241 - 2273
  • [29] COMPARISON OF 2 INDEPENDENT METHODS FOR DETERMINING NEUTRON-GAMMA SENSITIVITY OF A DOSIMETER
    WATERMAN, FM
    KUCHNIR, FT
    SKAGGS, LS
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (05): : 880 - 888
  • [30] Improved neutron-gamma discrimination for a 3He neutron detector using subspace learning methods
    Wang, C. L.
    Funk, L. L.
    Riedel, R. A.
    Berry, K. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 853 : 27 - 35