Intraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy

被引:16
|
作者
Alnawaiseh, Maged [1 ]
Zumhagen, Lars [1 ]
Rosentreter, Andre [1 ,2 ]
Eter, Nicole [1 ]
机构
[1] Univ Munster, Med Ctr, Dept Ophthalmol, Albert Schweitzer Campus 1,Bldg D15, D-48149 Munster, Germany
[2] Univ Wurzburg, Dept Ophthalmol, Wurzburg, Germany
来源
BMC OPHTHALMOLOGY | 2017年 / 17卷
关键词
Intraocular lens power calculation; DMEK; Ray tracing; REFRACTIVE OUTCOMES; PHAKIC EYES; KERATOPLASTY; STABILITY;
D O I
10.1186/s12886-017-0547-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The study presented here aims to optimize the accuracy of intraocular lens (IOL) power calculations in patients after DMEK by evaluation of the impact of the altered anterior/posterior corneal curvature relationship. Methods: Scheimpflug-based Oculus Pentacam imaging was performed after DMEK surgery for Fuchs endothelial dystrophy. The IOL power was calculated for all patients by ray tracing, aiming for postoperative emmetropia. We also performed the IOL calculation using four third-generation formulas (SRK-T, Hoffer-Q, Holladay-1 and Haigis). The residual refractions for the individual target IOL were compared and analyzed. Results: This retrospective study included 42 eyes of 33 patients (age 68.73 +/- 10.11 years) after DMEK surgery. The differences between the expected residual refraction based on ray tracing and that predicted with the third-generation formulas were statistically significant (all formulas p < 0.001). The highest mean difference in the residual refraction between the target IOL measured by ray tracing and that calculated with third-generation formulas was found for the Haigis formula (0.90 +/- 0.40 D), and the lowest mean difference for the SRK/T formula (0.73 +/- 0.49 D). Conclusions: DMEK surgery induced a relevant change in the anterior to posterior corneal curvature relationship; this needs to be taken into account in the IOL power calculation to avoid hyperopic refractive surprises.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Li, Liangpin
    Yuan, Liyun
    Yang, Kun
    Wu, Yanan
    Alafati, Simayilijiang
    Hua, Xia
    Wang, Yan
    Yuan, Xiaoyong
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [42] Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis
    Hao, Yuxu
    Fu, Jin
    Huang, Jin
    Chen, Ding
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [43] Intraocular lens power calculation with ray tracing based on AS-OCT and adjusted axial length after myopic excimer laser surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    Ribeiro, Filomena J.
    Dias, Joao Mendanha
    Coutinho, Catarina P.
    Barboni, Piero
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (08): : 947 - 953
  • [44] Use of Scheimpflug corneal anterior-posterior imaging in ray-tracing intraocular lens power calculation
    Miyata, Kazunori
    Otani, Shinichiro
    Honbou, Naoto
    Minami, Keiichiro
    ACTA OPHTHALMOLOGICA, 2013, 91 (07) : E546 - E549
  • [45] Accuracy of Constant C for Ray Tracing: Assisted Intraocular Lens Power Calculation in Normal Ocular Axial Eyes
    Chang, Ping-Jun
    Zhang, Fan
    Wang, Jia-Jun
    Zhao, Yun-E
    OPHTHALMIC RESEARCH, 2021, 64 (01) : 85 - 90
  • [46] Intraocular lens power calculation in virgin eyes: Accuracy of the Barrett Universal II formula and a Ray tracing software
    Fernandez-Roses, Joaquim
    Lamarca, Jose
    Pinero, David P.
    Barraquer, Rafael, I
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2954 - 2960
  • [47] Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy
    Li, Meng
    Wang, Jin-Da
    Zhang, Jing-Shang
    Mao, Ying-Yan
    Cao, Kai
    Wan, Xiu-Hua
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [48] Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy
    Meng Li
    Jin-Da Wang
    Jing-Shang Zhang
    Ying-Yan Mao
    Kai Cao
    Xiu-Hua Wan
    European Journal of Medical Research, 28
  • [49] Investigation of the myopic outcomes of the newer intraocular lens power calculation formulas in Korean patients with long eyes
    Kim, Jinchul
    Park, Joonsung
    Jo, Yoonjung
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [50] Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas
    Fabian, Ekkehard