Intraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy

被引:16
|
作者
Alnawaiseh, Maged [1 ]
Zumhagen, Lars [1 ]
Rosentreter, Andre [1 ,2 ]
Eter, Nicole [1 ]
机构
[1] Univ Munster, Med Ctr, Dept Ophthalmol, Albert Schweitzer Campus 1,Bldg D15, D-48149 Munster, Germany
[2] Univ Wurzburg, Dept Ophthalmol, Wurzburg, Germany
来源
BMC OPHTHALMOLOGY | 2017年 / 17卷
关键词
Intraocular lens power calculation; DMEK; Ray tracing; REFRACTIVE OUTCOMES; PHAKIC EYES; KERATOPLASTY; STABILITY;
D O I
10.1186/s12886-017-0547-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The study presented here aims to optimize the accuracy of intraocular lens (IOL) power calculations in patients after DMEK by evaluation of the impact of the altered anterior/posterior corneal curvature relationship. Methods: Scheimpflug-based Oculus Pentacam imaging was performed after DMEK surgery for Fuchs endothelial dystrophy. The IOL power was calculated for all patients by ray tracing, aiming for postoperative emmetropia. We also performed the IOL calculation using four third-generation formulas (SRK-T, Hoffer-Q, Holladay-1 and Haigis). The residual refractions for the individual target IOL were compared and analyzed. Results: This retrospective study included 42 eyes of 33 patients (age 68.73 +/- 10.11 years) after DMEK surgery. The differences between the expected residual refraction based on ray tracing and that predicted with the third-generation formulas were statistically significant (all formulas p < 0.001). The highest mean difference in the residual refraction between the target IOL measured by ray tracing and that calculated with third-generation formulas was found for the Haigis formula (0.90 +/- 0.40 D), and the lowest mean difference for the SRK/T formula (0.73 +/- 0.49 D). Conclusions: DMEK surgery induced a relevant change in the anterior to posterior corneal curvature relationship; this needs to be taken into account in the IOL power calculation to avoid hyperopic refractive surprises.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Cataract in keratoconus: Six-month results and a comparison of standard intraocular lens power calculation formulas
    Said, Reeda B.
    Farah, Chahid
    Chanbour, Wassef
    Jarade, Elias
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2022, 36 (02) : 201 - 206
  • [32] Comparison of different formulas for intraocular lens power calculation using a new optical biometer
    Kaya, F.
    Kocak, I.
    Aydin, A.
    Baybora, H.
    Karabela, Y.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (08): : 717 - 722
  • [33] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [34] Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power
    Norrby, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05): : 1000 - 1005
  • [35] Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract
    Wang, Menghan
    Li, Dongfang
    Fan, Zheng
    Zhang, Jing
    Zhou, Jinyan
    Huang, Yusen
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2023, 60 (02) : 139 - +
  • [36] Refractive Outcomes With New Generation Formulas for Intraocular Lens Power Calculation in Radial Keratotomy Patients
    Ferrara, Silvia
    Crincoli, Emanuele
    Savastano, Alfonso
    Savastano, Maria Cristina
    Catania, Fiammetta
    Rizzo, Stanislao
    CORNEA, 2024, 43 (02) : 178 - 183
  • [37] Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer
    Kim, Se Young
    Lee, Seung Hyun
    Kim, Na Rae
    Chin, Hee Seung
    Jung, Ji Won
    PLOS ONE, 2020, 15 (01):
  • [38] Comparison of the accuracy of nine intraocular lens power calculation formulas using partial coherence interferometry
    Maroun, A.
    El Shami, M.
    Hoyek, S.
    Antoun, J.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (04): : 341 - 347
  • [39] Third- and fourth-generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia
    Amro, Mazen
    Chanbour, Wassef
    Arej, Nicolas
    Jarade, Elias
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11): : 1321 - 1325
  • [40] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Liangpin Li
    Liyun Yuan
    Kun Yang
    Yanan Wu
    Simayilijiang Alafati
    Xia Hua
    Yan Wang
    Xiaoyong Yuan
    Scientific Reports, 13 (1)