Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis

被引:0
|
作者
Hao, Yuxu [1 ]
Fu, Jin [1 ]
Huang, Jin [1 ]
Chen, Ding [1 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, 270 Xueyuan Rd, Wenzhou 325000, Zhejiang, Peoples R China
关键词
Cataract; High myopia; IOL calculation; Artificial intelligence; EYES;
D O I
10.1007/s10792-024-03227-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The accuracy of intraocular lens (IOL) calculations is one of the key indicators for determining the success of cataract surgery. However, in highly myopic patients, the calculation errors are relatively larger than those in general patients. With the continuous development of artificial intelligence (AI) technology, there has also been a constant emergence of AI-related calculation formulas. The purpose of this investigation was to evaluate the accuracy of AI calculation formulas in calculating the power of IOL for highly myopic patients. Methods We searched the relevant literature through August 2023 using three databases: PubMed, EMBASE, and the Cochrane Library. Six IOL calculation formulas were compared: Kane, Hill-RBF, EVO, Barrett II, Haigis, and SRK/T. The included metrics were the mean absolute error (MAE) and percentage of errors within +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D. Results The results showed that the MAE of Kane was significantly lower than that of Barrett II (mean difference = - 0.03 D, P = 0.02), SRK/T (MD = - 0.08 D, P = 0.02), and Haigis (MD = - 0.12 D, P < 0.00001). The percentage refractive prediction errors for Kane at +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D were significantly greater than those for SRK/T (P = 0.007, 0.003, and 0.01, respectively) and Haigis (P = 0.009, 0.0001, and 0.001, respectively). No statistically significant differences were noted between Hill-RBF and Barret, but Hill-RBF was significantly better than SRK/T and Haigis. Conclusion The AI calculation formulas showed more accurate results compared with traditional formulas. Among them, Kane has the best performance in calculating IOL degrees for highly myopic patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The accuracy of intraocular lens power calculation formulas based on artificial intelligence in highly myopic eyes: a systematic review and network meta-analysis
    Zhou, Yi
    Dai, Minhui
    Sun, Lingyu
    Tang, Xiangyi
    Zhou, Ling
    Tang, Zhiyao
    Jiang, Jian
    Xia, Xiaobo
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [2] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [3] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes
    Wang, Qiwei
    Jiang, Wu
    Lin, Tiao
    Wu, Xiaohang
    Lin, Haotian
    Chen, Weirong
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (04): : 356 - 363
  • [5] Network meta-analysis of intraocular lens power calculation formulas based on artificial intelligence in short eyes
    Xin Zheng
    Meng Li
    Zhao-Xing Guo
    Zhi-Yong Tian
    Jing-Shang Zhang
    Ying-Yan Mao
    Peng Zhao
    Zhong-Yan Li
    Xiu-Hua Wan
    BMC Ophthalmology, 25 (1)
  • [6] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Jia-Qing
    Zou, Xu-Yuan
    Zheng, Dan-Ying
    Chen, Wei-Rong
    Sun, Ao
    Luo, Li-Xia
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 943 - 948
  • [7] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Jia-Qing Zhang
    Xu-Yuan Zou
    Dan-Ying Zheng
    Wei-Rong Chen
    Ao Sun
    Li-Xia Luo
    International Journal of Ophthalmology, 2019, (06) : 943 - 948
  • [8] Accuracy of Intraocular Lens Power Calculation Formulas in Pediatric Cataract Patients: A Systematic Review and Meta-Analysis
    Zhong, Yueyang
    Yu, Yibo
    Li, Jinyu
    Lu, Bing
    Li, Su
    Zhu, Yanan
    FRONTIERS IN MEDICINE, 2021, 8
  • [9] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [10] A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence
    Stopyra, Wiktor
    Cooke, David L.
    Grzybowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)