Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis

被引:0
|
作者
Hao, Yuxu [1 ]
Fu, Jin [1 ]
Huang, Jin [1 ]
Chen, Ding [1 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, 270 Xueyuan Rd, Wenzhou 325000, Zhejiang, Peoples R China
关键词
Cataract; High myopia; IOL calculation; Artificial intelligence; EYES;
D O I
10.1007/s10792-024-03227-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The accuracy of intraocular lens (IOL) calculations is one of the key indicators for determining the success of cataract surgery. However, in highly myopic patients, the calculation errors are relatively larger than those in general patients. With the continuous development of artificial intelligence (AI) technology, there has also been a constant emergence of AI-related calculation formulas. The purpose of this investigation was to evaluate the accuracy of AI calculation formulas in calculating the power of IOL for highly myopic patients. Methods We searched the relevant literature through August 2023 using three databases: PubMed, EMBASE, and the Cochrane Library. Six IOL calculation formulas were compared: Kane, Hill-RBF, EVO, Barrett II, Haigis, and SRK/T. The included metrics were the mean absolute error (MAE) and percentage of errors within +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D. Results The results showed that the MAE of Kane was significantly lower than that of Barrett II (mean difference = - 0.03 D, P = 0.02), SRK/T (MD = - 0.08 D, P = 0.02), and Haigis (MD = - 0.12 D, P < 0.00001). The percentage refractive prediction errors for Kane at +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D were significantly greater than those for SRK/T (P = 0.007, 0.003, and 0.01, respectively) and Haigis (P = 0.009, 0.0001, and 0.001, respectively). No statistically significant differences were noted between Hill-RBF and Barret, but Hill-RBF was significantly better than SRK/T and Haigis. Conclusion The AI calculation formulas showed more accurate results compared with traditional formulas. Among them, Kane has the best performance in calculating IOL degrees for highly myopic patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [32] Accuracy of Artificial Intelligence Formulas and Axial Length Adjustments for Highly Myopic Eyes
    Cheng, Huanhuan
    Wang, Li
    Kane, Jack X.
    Li, Jianbing
    Liu, Liangping
    Wu, Mingxing
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 223 : 100 - 107
  • [33] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lin, Lei
    Fang, Jiayan
    Sun, Weijie
    Gu, Siyi
    Xu, Liming
    Chen, Siping
    Chang, Pingjun
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (04) : 1019 - 1027
  • [34] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lei Lin
    Jiayan Fang
    Weijie Sun
    Siyi Gu
    Liming Xu
    Siping Chen
    Pingjun Chang
    Yun-e Zhao
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1019 - 1027
  • [35] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia
    Stopyra, Wiktor
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (02) : 225 - 230
  • [36] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial hyperopia
    Stopyra, Wiktor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [37] A systemic review and network meta-analysis of accuracy of intraocular lens power calculation formulas in primary angle-closure conditions
    Lu, Wenhan
    Hou, Yu
    Yang, Hongfang
    Sun, Xinghuai
    PLOS ONE, 2022, 17 (10):
  • [38] Accuracy of Intraocular Lens Power Formulas Modified for Patients with Keratoconus
    Kane, Jack X.
    Connell, Benjamin
    Yip, Harry
    McAlister, James C.
    Beckingsale, Peter
    Snibson, Grant R.
    Chan, Elsie
    OPHTHALMOLOGY, 2020, 127 (08) : 1037 - 1042
  • [39] Accuracy of 12 Intraocular Lens Power Formulas After Corneal Myopic Refractive Surgery
    Rong, Xin
    Liu, Jiewei
    Jiang, Lin
    Wang, Xiaogang
    Feng, Tianfeng
    Lu, Zhenyang
    Fan, Zeqi
    Yan, Hua
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (06) : e354 - e361
  • [40] Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Maleita, Diogo
    Gil, Pedro
    Maduro, Vitor
    Costa, Livio
    Marques, Nuno
    Branco, Joao
    Alves, Nuno
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2021, 7 (01)