Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis

被引:0
|
作者
Hao, Yuxu [1 ]
Fu, Jin [1 ]
Huang, Jin [1 ]
Chen, Ding [1 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, 270 Xueyuan Rd, Wenzhou 325000, Zhejiang, Peoples R China
关键词
Cataract; High myopia; IOL calculation; Artificial intelligence; EYES;
D O I
10.1007/s10792-024-03227-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The accuracy of intraocular lens (IOL) calculations is one of the key indicators for determining the success of cataract surgery. However, in highly myopic patients, the calculation errors are relatively larger than those in general patients. With the continuous development of artificial intelligence (AI) technology, there has also been a constant emergence of AI-related calculation formulas. The purpose of this investigation was to evaluate the accuracy of AI calculation formulas in calculating the power of IOL for highly myopic patients. Methods We searched the relevant literature through August 2023 using three databases: PubMed, EMBASE, and the Cochrane Library. Six IOL calculation formulas were compared: Kane, Hill-RBF, EVO, Barrett II, Haigis, and SRK/T. The included metrics were the mean absolute error (MAE) and percentage of errors within +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D. Results The results showed that the MAE of Kane was significantly lower than that of Barrett II (mean difference = - 0.03 D, P = 0.02), SRK/T (MD = - 0.08 D, P = 0.02), and Haigis (MD = - 0.12 D, P < 0.00001). The percentage refractive prediction errors for Kane at +/- 0.25 D, +/- 0.50 D, and +/- 1.00 D were significantly greater than those for SRK/T (P = 0.007, 0.003, and 0.01, respectively) and Haigis (P = 0.009, 0.0001, and 0.001, respectively). No statistically significant differences were noted between Hill-RBF and Barret, but Hill-RBF was significantly better than SRK/T and Haigis. Conclusion The AI calculation formulas showed more accurate results compared with traditional formulas. Among them, Kane has the best performance in calculating IOL degrees for highly myopic patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [22] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Liangpin Li
    Liyun Yuan
    Kun Yang
    Yanan Wu
    Simayilijiang Alafati
    Xia Hua
    Yan Wang
    Xiaoyong Yuan
    Scientific Reports, 13 (1)
  • [23] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Li, Liangpin
    Yuan, Liyun
    Yang, Kun
    Wu, Yanan
    Alafati, Simayilijiang
    Hua, Xia
    Wang, Yan
    Yuan, Xiaoyong
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [24] Accuracy of Intraocular Lens Power Calculation Formulas in Myopic Eyes with Target Refractions of Emmetropia and Intentional Myopia
    Sakai, Daiki
    Hiranni, Yasuhiko
    Nakamura, Makoto
    Kurinnoto, Yasuo
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4535 - 4541
  • [25] Accuracy of 7 Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Extremely Long Caucasian Eyes
    Stopyra, Wiktor
    Voytsekhivskyy, Oleksiy
    Grzybowski, Andrzej
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 271 : 337 - 346
  • [26] Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis
    Hongyu Li
    Zi Ye
    Yu Luo
    Zhaohui Li
    International Ophthalmology, 2023, 43 : 619 - 633
  • [27] Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis
    Li, Hongyu
    Ye, Zi
    Luo, Yu
    Li, Zhaohui
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (02) : 619 - 633
  • [28] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [29] Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry
    Helaly, Hany Ahmed
    Elhady, Amr Mohamed
    Elnaggar, Osama Ramadan
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2589 - 2597
  • [30] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342