Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections

被引:33
|
作者
Ugurel, Cihan Sadi [1 ]
Steiner, Martin [2 ]
Isik-Ozkol, Gul [1 ]
Kutay, Omer [1 ]
Kern, Matthias [2 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, TR-34093 Istanbul, Turkey
[2] Univ Kiel, Sch Dent, Dept Prosthodont Propaedeut & Dent Mat, Kiel, Germany
关键词
dental implant-abutment connection; mechanical strength; morse taper; PROSPECTIVE CLINICAL-EVALUATION; SINGLE-TOOTH REPLACEMENTS; FIXED PARTIAL DENTURES; LEAST; 5; YEARS; COMPLICATION RATES; OBSERVATION PERIOD; IN-VITRO; BRANEMARK IMPLANTS; INTERFACE DESIGN; DENTAL IMPLANTS;
D O I
10.1111/clr.12303
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveThe screwless morse taper (SMT) implant-abutment connection is an alternative to conventional external or internal screw-retained (ISR) connections. The aim of this in vitro study was to evaluate mechanical resistance of the SMT connection and to compare it with three different ISR connections. Materials and MethodsFour implant systems were tested in this study: SMT system; Tasarimmed Octo (Istanbul, Turkey), ISR systems; Straumann Bone Level (Basel, Switzerland), Biohorizons Internal (Birmingham, AL, USA), and Dentsply Friadent Xive (Mannheim, Germany). Overall, 64 specimens with stylized single crowns were prepared: 32 for dynamic loading (DL) and 32 for static loading (SL). DL was carried out using a chewing simulator with 120N at 1.75Hz for 1.2x10(6) cycles, and SL was performed with a universal testing machine at a crosshead speed of 2mm/min with an angulation of 30 degrees. Cycles until failure from DL and fracture/bending loads at SL were recorded. Statistical analyses were made with Dunn's multiple comparison. ResultsMedian cycles until failure in DL were as follows: Octo 86,354 (24,810-153,875), Straumann 1,200,000 (1,156,618-1,200,000), Biohorizons 539,719 (437,224-858,732), Xive 139,411 (139,411-139,411). Median fracture/bending loads in Newton at SL were as follows: Octo 429.6 (404.5-482.7), Straumann 574.6 (544.6-629.9), Biohorizons 548.7 (532.9-567.3), Xive 431.5 (412.5-520.5). There were significant differences between the implant systems under both loading conditions (P0.05) revealing that the Octo implant system's SMT connection showed significantly lower cycles to failures and lower fracture/bending loads compared with the ISR connections of the Straumann and Biohorizons implant systems. However, there was no significant difference compared with the Xive implant system. ConclusionThe mechanical resistance of the screwless morse taper implant system is lower than that of the ISR implant systems that might result in more frequent clinical complications.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [21] Microbial penetration of the internal part of cement-retained implant-abutment connections
    Fanali, S
    Ciavarelli, L
    Traini, T
    Piattelli, M
    Tripodi, D
    Scarano, A
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1246 - 1246
  • [22] Implant-Abutment Connections: A Structured Review
    Hariharan A.S.
    Sivaswamy V.
    Subhashini R.
    Journal of Long-Term Effects of Medical Implants, 2022, 33 (01) : 47 - 56
  • [23] Microbial Leakage through Three Different Implant-Abutment Interfaces on Morse Taper Implants In Vitro
    Ribeiro, Ricardo Faria
    da Mata, Victor Barboza
    Tomaselli, Lucas de Oliveira
    Simionato, Anselmo Agostinho
    Santos, Emerson de Souza
    Faria, Adriana Claudia Lapria
    Rodrigues, Renata Cristina Silveira
    do Nascimento, Cassio
    DENTISTRY JOURNAL, 2024, 12 (07)
  • [24] Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study
    Garcia-Gonzalez, Marta
    Gonzalez-Gonzalez, Ignacio
    Garcia-Garcia, Ismael
    Blason-Gonzalez, Sergio
    Lamela-Rey, Maria Jesus
    Fernandez-Canteli, Alfonso
    Alvarez-Arenal, Angel
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 318.e1 - 318.e10
  • [25] Restoring screw-retained implant prostheses
    Williamson, R
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2000, 131 (01): : 73 - 74
  • [26] Bacterial Leakage Evaluation Through DNA-DNA Checkerboard Hybridization Technique in Morse Taper Implant-Abutment Connections: An In Vitro Study
    Teixeira, Wendel
    do Nascimento, Cassio
    Pereira, Rafael Martins Afonso
    Mendonca, Gustavo
    Fernandes, Gustavo Vicentis de Oliveira
    Wang, Hom-Lay
    Pedrazzi, Vinicius
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 313 - +
  • [27] Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant -: A nonlinear finite element stress analysis
    Akça, K
    Çehreli, MC
    Iplikçioglu, H
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) : 444 - 454
  • [28] Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loading
    Alevizakos, Vasilios
    Mosch, Richard
    Mitov, Gergo
    Othman, Ahmed
    von See, Constantin
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (03): : 152 - 159
  • [29] The influence of the restorative material on the mechanical behavior of screw-retained hybrid-abutment-crowns
    Yazigi, Christine
    Kern, Matthias
    Chaar, Mohamed Sad
    Libecki, Wojtek
    Elsayed, Adham
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 111 (111)
  • [30] Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
    Rico-Coderch, Aitana
    Felix, Luis F.
    Sola-Ruiz, Maria Fernanda
    Medina, Michell
    Agustin-Panadero, Ruben
    Ortega, Rocio
    Cascos, Rocio
    Gomez-Polo, Miguel
    METALS, 2024, 14 (07)