Analysis of Nanograms of Cadmium Using a Portable Total Reflection X-Ray Fluorescence Spectrometer

被引:4
|
作者
Kunimura, Shinsuke [1 ]
Tee, Deh Ping [2 ]
Kawai, Jun [2 ]
机构
[1] RIKEN, Mat Fabricat Lab, Inst Phys & Chem Res, Wako, Saitama 3510198, Japan
[2] Kyoto Univ, Dept Mat Sci & Engn, Kyoto 6068501, Japan
关键词
total reflection X-ray fluorescence; portable spectrometer; cadmium;
D O I
10.2355/tetsutohagane.97.81
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Nanograms of Cd are measured with a portable total reflection X-ray fluorescence spectrometer. A relationship between a detection limit for Cd and counting time is investigated. A Cd detection limit is improved with the increase in counting time, and a detection limit of 1 ng is achieved when a measurement is performed for 1800s. Cadmium quantitative performance is shown. Yttrium is used as an internal standard element, and the Cd K alpha/Y K alpha intensity ratio is linear with mass of Cd in the range from 10 to 1010 ng. Detection limits for Cd obtained with or without a 30 mu m thick Mo absorber are compared. The spectral background is reduced using the Mo absorber, leading to an increase in the signal to background ratio of the Cd K alpha line. However, the use of the Mo absorber results in a decrease in the net intensity of the Cd K alpha line. Therefore, a detection limit obtained with the Mo absorber is as low as that obtained without an absorber.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 50 条
  • [21] Analysis of Metals Eluted from Stainless Steel in Ultrapure Water Using a Portable Total Reflection X-ray Fluorescence Spectrometer
    Kako, Arisa
    Kunimura, Shinsuke
    BUNSEKI KAGAKU, 2022, 71 (7-8) : 431 - 435
  • [22] Trace elemental analysis of commercial bottled drinking water by a portable total reflection X-ray fluorescence spectrometer
    Kunimura, Shinsuke
    Kawai, Jun
    ANALYTICAL SCIENCES, 2007, 23 (10) : 1185 - 1188
  • [23] Analysis of art objects using a portable x-ray fluorescence spectrometer
    Moioli, P
    Seccaroni, C
    X-RAY SPECTROMETRY, 2000, 29 (01) : 48 - 52
  • [24] Total-reflection x-ray fluorescence spectrometer using a rotating anode
    Chalmers Univ of Technology, Goteborg, Sweden
    Nucl Instrum Methods Phys Res Sect A, 3 (553-559):
  • [25] A total-reflection X-ray fluorescence spectrometer using a rotating anode
    Pettersson, RP
    Boman, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (03): : 553 - 559
  • [26] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Shinsuke Kunimura
    Tomoki Shinkai
    Analytical Sciences, 2017, 33 : 635 - 637
  • [27] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Kunimura, Shinsuke
    Shinkai, Tomoki
    ANALYTICAL SCIENCES, 2017, 33 (05) : 635 - 638
  • [28] Portable Total Reflection X-ray Fluorescence Spectrometer with a Detection Limit in the 100 ng/L Range
    Akahane, Yuya
    Nakazawa, Sunfun
    Kunimura, Shinsuke
    ISIJ INTERNATIONAL, 2022, 62 (05) : 871 - 874
  • [29] STANDARDLESS X-RAY FLUORESCENCE ANALYSIS OF ORTHODONTIC CEMENTS USING A PORTABLE SPECTROMETER
    Suciu, Ioana
    Bartok, Ruxandra
    Preoteasa, Elena S.
    Dimitriu, B.
    Preoteasa, E. A.
    Constantinescu, B.
    Stan, Daniela
    Moldoveanu, Georgiana
    Ionescu, Ileana
    Bodnar, Dana Cristina
    ROMANIAN JOURNAL OF PHYSICS, 2015, 60 (9-10): : 1483 - 1489
  • [30] STANDARDLESS X-RAY FLUORESCENCE ANALYSIS OF ENDODONTIC SEALERS USING A PORTABLE SPECTROMETER
    Suciu, Ioana
    Preoteasa, Elena S.
    Preoteasa, E. A.
    Chiojdeanu, Catalina
    Constantlnescu, B.
    Dimitriu, B.
    Perlea, Paula
    Iliescu, Al. A.
    Bodnar, Dana
    ROMANIAN JOURNAL OF PHYSICS, 2015, 60 (3-4): : 528 - 548