The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector

被引:5
|
作者
Choi, Yu-Na
Lee, Seung-Wan
Cho, Hyo-Min
Ryu, Hyun-Ju
Lee, Young-Jin
Kim, Hee-Joung [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon energy weighting; GATE; CNR; MONTE-CARLO-SIMULATION; DIGITAL MAMMOGRAPHY; GATE; PLATFORM; PET; CT;
D O I
10.3938/jkps.59.3114
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Development of photon counting detectors with the ability of energy discrimination would provide additional information. These detectors could improve the contrast-to-noise ratio (CNR) by using photon energy weighting with energy-dependent weighting factors. The purpose of this study was to evaluate the effect of photon energy weighting using GEANT4 Application for Tomographic Emission (GATE) version 6.0. The photon energy weighting depends on the X-ray attenuation coefficient of contrast elements and background materials. In this study, we simulated a photon counting X-ray imaging system. We designed a cadmium telluride (CdTe) photon counting detector (model PID-350, AJAT, Finland), the micro focus X-ray source (model L8601-01, Hamamatsu, Japan) and two phantoms with GATE. In the first case, we were concerned with calcifications in breast tissue or soft tissue. We defined a cubic phantom made of poly (methyl methacrylate) (PMMA) material with a thickness of 40 mm including four CaCO3 contrast elements with different thickness of 1.0, 3.0, 5.0, and 7.0 mm. In the second case, we designed a second phantom for contrast-enhanced digital mammography (CEDM). We defined two cylindrical phantoms made of PMMA with thicknesses of 30 and 40 mm, including four iodine contrast elements with different thicknesses of 0.3, 0.5, 1.0, and 1.5 mm. The effect of photon energy weighting was investigated in terms of the CNR. In all cases, photon energy weighting improve the CNR. The CNR improvements for CaCO3 with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.41, 1.32, 1.43, and 1.56, respectively. For the second phantom with a thickness of 30 mm, the CNR improvements of iodine contrast elements with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.01, 1.03, 1.09, and 1.13, respectively, and for the second phantom with a thicknesses of 40 mm, the CNR improvements of iodine contrast elements with thickness of 1.0, 3.0, 5.0, and 7.0 mm were 1.05, 1.07, 1.16, and 1.10, respectively. This study demonstrates that the photon energy weighting using additional information improves the CNR, which allows better detection of calcium, a contrast agent or other contrast elements.
引用
收藏
页码:3114 / 3119
页数:6
相关论文
共 50 条
  • [41] X-Ray Fluorescence for Energy Response Calibration of a Photon Counting Detector: A Simulation Study
    Cho, H.
    Ding, H.
    Ziemer, B.
    Molloi, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 145 - 145
  • [42] A large area photon counting X-ray detector with indirect conversion
    Durst, Roger
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : A205 - A205
  • [43] Evaluation of a hybrid photon counting pixel detector for X-ray polarimetry
    Michel, T.
    Durst, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02): : 188 - 195
  • [44] Dual Threshold X-ray Photon Counting Pixel Array Detector
    Williams, George M., Jr.
    Rhee, Jehyuk
    Zou, Haifeng
    Lee, Adam
    Ross, Steve
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [45] PILATUS: A single photon counting pixel detector for X-ray applications
    Henrich, B.
    Bergamaschi, A.
    Broennimann, C.
    Dinapoli, R.
    Eikenberry, E. F.
    Johnson, I.
    Kobas, M.
    Kraft, P.
    Mozzanica, A.
    Schmitt, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 247 - 249
  • [46] X-ray spectroscopy with a photon-counting SiPM-based scintillation detector
    Ceravolo, S.
    Gargiulo, R.
    Paesani, D.
    Russo, A.
    Sarra, I.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [47] Superfine photon-counting detector for 0.1-100 keV X-ray imaging
    Miyata, E
    Tawa, N
    Mukai, K
    Miki, A
    Koizumi, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 56 - 65
  • [48] Photon counting medical X-ray Imaging system using Microchannel Plate (MCP) detector
    Shikhaliev, P
    Xu, T
    Molloi, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1331 - 1331
  • [49] Spectroscopic X-ray imaging with photon counting pixel detectors
    Tlustos, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (02): : 823 - 828
  • [50] Evaluation of a photon-counting X-ray imaging system
    Lundqvist, M
    Cederström, B
    Chmill, V
    Danielsson, M
    Hasegawa, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1530 - 1536