摘要
Development of photon counting detectors with the ability of energy discrimination would provide additional information. These detectors could improve the contrast-to-noise ratio (CNR) by using photon energy weighting with energy-dependent weighting factors. The purpose of this study was to evaluate the effect of photon energy weighting using GEANT4 Application for Tomographic Emission (GATE) version 6.0. The photon energy weighting depends on the X-ray attenuation coefficient of contrast elements and background materials. In this study, we simulated a photon counting X-ray imaging system. We designed a cadmium telluride (CdTe) photon counting detector (model PID-350, AJAT, Finland), the micro focus X-ray source (model L8601-01, Hamamatsu, Japan) and two phantoms with GATE. In the first case, we were concerned with calcifications in breast tissue or soft tissue. We defined a cubic phantom made of poly (methyl methacrylate) (PMMA) material with a thickness of 40 mm including four CaCO3 contrast elements with different thickness of 1.0, 3.0, 5.0, and 7.0 mm. In the second case, we designed a second phantom for contrast-enhanced digital mammography (CEDM). We defined two cylindrical phantoms made of PMMA with thicknesses of 30 and 40 mm, including four iodine contrast elements with different thicknesses of 0.3, 0.5, 1.0, and 1.5 mm. The effect of photon energy weighting was investigated in terms of the CNR. In all cases, photon energy weighting improve the CNR. The CNR improvements for CaCO3 with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.41, 1.32, 1.43, and 1.56, respectively. For the second phantom with a thickness of 30 mm, the CNR improvements of iodine contrast elements with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.01, 1.03, 1.09, and 1.13, respectively, and for the second phantom with a thicknesses of 40 mm, the CNR improvements of iodine contrast elements with thickness of 1.0, 3.0, 5.0, and 7.0 mm were 1.05, 1.07, 1.16, and 1.10, respectively. This study demonstrates that the photon energy weighting using additional information improves the CNR, which allows better detection of calcium, a contrast agent or other contrast elements.
引用
收藏
页码:3114 / 3119
页数:6
相关论文
共 50 条
  • [31] MicroComputed tomography with a photon-counting X-ray detector
    Frey, Ec.
    Taguchi, K.
    Kapusta, M.
    Xu, J.
    Orskaug, T.
    Ninive, I.
    Wagenaar, D.
    Patt, B.
    Tsui, B. M. W.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [32] Characterization of Seamless CdTe Photon Counting X-Ray Detector
    Kauppinen, Matti
    Winkler, Alex
    Lamsa, Vili
    Matikkala, Mikko
    Zoladz, Miroslaw
    Grybos, Pawel
    Kleczek, Rafal
    Kmon, Piotr
    Szczygiel, Robert
    Fabritius, Tapio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [33] Silicon-based photon counting X-ray detector for synchrotron applications
    Fant, A
    French, MJ
    Murray, P
    Seller, P
    Manolopoulos, S
    Thomas, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 442 - 447
  • [34] Improvement of the visibility for X-ray Phase Contrast Imaging using Photon Counting Detector
    Sano, S.
    Tanabe, K.
    Yoshimuta, T.
    Kimura, K.
    Shirai, T.
    Doki, T.
    Horiba, A.
    Sato, T.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [35] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [36] Image Reconstruction for X-ray K-edge Imaging with a Photon Counting Detector
    Meng, Bo
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [37] Characteristic performance investigation of a photon counting detector for X-ray fluorescence imaging applications
    Ren, Liqiang
    Ghani, Muhammad U.
    Wu, Di
    Li, Yuhua
    Chen, Wei R.
    Wang, Ge
    Zheng, Bin
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES XII, 2017, 10065
  • [38] Biomedical x-ray imaging with a GaAs photon-counting detector: A comparative study
    Scholz, J.
    Birnbacher, L.
    Petrich, C.
    Riedel, M.
    Heck, L.
    Gkoumas, S.
    Sellerer, T.
    Achterhold, K.
    Herzen, J.
    APL PHOTONICS, 2020, 5 (10)
  • [39] Performance of Amorphous Selenium Based Unipolar Charge Sensing Detector for Photon Counting X-ray Imaging
    Camlica, Ahmet
    Lee, Denny
    Jang, Hyunsuk
    Arnab, Salman M.
    Fang, Yuan
    Kabir, M. Z.
    Karim, S. Karim
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [40] Modeling Spectral Distortions in Energy Resolved Photon-counting X-ray Detector
    Wang, Xiaolan
    Meier, Dirk
    Hugg, James
    Chowdhury, Samir
    Wagenaar, Douglas
    Patt, Bradley
    Frey, Eric
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3054 - 3057